• 제목/요약/키워드: Thermal-Comfort

검색결과 700건 처리시간 0.025초

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

여름철 공원 수림지 가장자리의 온열환경 기울기 변화 - 하동송림과 함양상림을 대상으로 - (The Gradient Variation of Thermal Environments on the Park Woodland Edge in Summer - A Study of Hadongsongrim and Hamyangsangrim -)

  • 류남형;이춘석
    • 한국조경학회지
    • /
    • 제43권6호
    • /
    • pp.73-85
    • /
    • 2015
  • 본 연구는 공원 수림지 경계로부터 내부로의 거리에 따른 수림지 가장자리의 온열환경에 대한 효과를 규명하고자 하였다. 이를 위해 전형적인 여름 날씨를 나타낸 2015년 7월 31일부터 8월 5일까지 6일간 소도읍에 소재하고 있는 장령림인 하동송림의 소나무 순림(수령: $100{\pm}33$년, 울폐도: 75%, 수고: $12.8{\pm}2.7m$, 지하고: $9.8{\pm}2.7m$, N $35^{\circ}03^{\prime}34.7^{{\prime}{\prime}}$, E $127^{\circ}44^{\prime}43.3^{{\prime}{\prime}}$, 표고 7~10m) 남측 가장자리와 함양상림의 졸참나무-개서어나무 군락(수령: 졸참나무 58~123년, 개서어나무 102~125년, 울폐도: 96%, 수고: 교목층 $18.6{\pm}2.3m$, 아교목층 $5.9{\pm}3.2m$, 관목층 $0.5{\pm}0.5m$, 지하고는 교목층 $11.0{\pm}3.2m$, 아교목층 $3.1{\pm}1.7m$, 관목층 $0.2{\pm}0.3m$, 초본층의 피도 60%, N $35^{\circ}31^{\prime}28.1^{{\prime}{\prime}}$, E $127^{\circ}43^{\prime}09.8^{{\prime}{\prime}}$, 표고 170~180m) 동측 가장자리의 경계로부터 내부로의 거리별 기온, 상대습도, 풍속, MRT나 UTCI를 측정 및 분석하였다. 그리고 비선형 시그모이드 함수를 적용하여 수림지 가장자리가 가지는 경계로부터의 거리에 따른 기온, 상대습도, 풍속, MRT, UTCI의 저감효과를 구명하였다. 깊이의 결과 값이 -를 나타내는 것은 수림지의 바깥을 의미한다. 1) 최고 기온, 최저 상대습도, 최고 기온시 풍속에 대한 수림지 가장자리 효과가 미치는 깊이는 상록침엽수림인 하동송림의 경우는 수림지의 경계로부터 각각 $12.7{\pm}4.9m$, $15.8{\pm}9.8m$ 그리고 $23.8{\pm}26.2m$였으며, 낙엽활엽수림인 함양상림의 경우는 수림지의 경계로부터 각각 $3.7{\pm}2.2m$, $4.9{\pm}4.4m$ 그리고 $2.6{\pm}7.8m$였다. 2) 이용자가 체감하는 더위에 직접적인 영향을 주는 인체가 흡수한 온열환경에 근거한 최고 MRT와 최고 UTCI(체감더위지수)에 대한 수림지 가장자리 효과가 미치는 깊이는 하동송림의 경우는 수림지의 경계로부터 각각 $7.1{\pm}1.7m$$4.3{\pm}4.6m$였으며, 함양상림의 경우는 수림지의 경계로부터 각각 $5.8{\pm}4.9m$$3.5{\pm}4.1m$였다. 3) 미기후 즉 온열환경 요소인 기온, 상대습도, 풍속 그리고 인체가 흡수한 온열환경에 근거한 주간(10:00~17:00) MRT와 UTCI에 대한 수림지 가장자리의 효과는 식생밀도가 상대적으로 높고, 하층식생이 발달한 함양상림이 식생밀도가 낮고, 하층식생의 거의 없는 하동송림에 비해 높게 나타났다. 따라서 체감 더위지수인 UTCI의 10분 평균값이 최댓값을 나타낸 시점을 기준으로 하면, 수림지 경계로부터 내부로의 거리가 하동송림의 경우는 $4.3{\pm}4.6m$, 함양상림의 경우는 $3.5{\pm}4.1m$에서 온열환경 기울기의 변화가 비교적 완만해지므로, 수림지 계획시 이용객의 온열환경을 고려한 완충대의 적정 폭은 하동송림의 경우는 4.3~8.9m, 함양상림의 경우는 3.5~7.6m이다. 또한 온열환경에 대한 완충효과를 극대화하기 위해서, 수림지 완충대 식생의 수직구조는 다층 구조의 수관과 닫힌 가장자리로 하여야 한다.

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

스커트와 슬랙스의 의복착용습관이 인체의 체온조절에 미치는 영향 (Effect of Clothing Habit on Thermoregulation of Body A Comparative Study of Skirt and Slacks)

  • 최영희;이순원
    • 한국의류학회지
    • /
    • 제20권6호
    • /
    • pp.983-991
    • /
    • 1996
  • This study focusses on how the skirt or slacks wearing habit affects the female physiology in her daily life. The healthy female college students have been trained to wear either skirt (group A) or slacks (group B) from late August to early January in order to study the effects of clothing habit on thermoregulatory responses. Also, the themoregulatory responses have been compared the healthy students groups with a physical trained students group (group C) to examine the effects of clothing habit. The changes in body temperatures of students have been studied under the cool environmental condition (15$\pm$1$^{\circ}C$, 60$\pm$5% RH, 0.25 m/sec). The results were as follows: 1. Rectal temperature of the group A was 0.4$^{\circ}C$ lower at 36.9$^{\circ}C$ than that of the group B The groups A and B were found identical before the training, while the groups A and C were identical after the training. 2. Mean skin temperature of the group A was 1.2$^{\circ}C$ lower than that of the group B. The groups A and C were identical after the training. 3. The thermal sensation was reflected to be cool by the group A and to be cold by the group B. As for the humidity sensation, the group A felt average, whereas the group B reported between average and slightly humid. In the case of comfort sensation, the group A felt average, while the group B felt between average and slightly uncomfortable. In summary, the 18 weeks of training has provided the skirt group an improved acclimatization to the cold environment . This group also showed an insulative-hypothermic adapta lion in a cold ambient temperature, as was the case for the physical trained group. It is concluded that wearing a skirt for a long period of time can be helpful to human body through gaining of thermoregulatory abilities.

  • PDF

영유아 교육시설에서의 실내공기질 평가 (The Evaluation of Air Quality in Educational Child Care Centers)

  • 임지혜;방승기;손장열
    • 교육녹색환경연구
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 2010
  • It is indispensable for child care centers to investigate and manage indoor air quality (IAQ) because they perform education and day care for children who usually have weak immunity. Nevertheless, there is insufficient research being done, given its importance. This study aims to investigate indoor pollutants' concentration and to seek the causes in order to improve the air quality conditions. Also it aims to secure data which can be used for further researches. Measurements were performed for air temperature, relative humidity, carbon dioxide, carbon monoxide, fine particle mass, formaldehyde and volatile organic compounds. Temperature, humidity, CO and CO2 were measured 30times(1min/time) and PM10 was measured 10times (3min/time). Formaldehyde and volatile organic compounds were measured and analyzed based on The Indoor Air Quality Official Test Method. The results show that the temperatures were within the comfort zone in over half of the centers. CO2 was found to be the main pollutants as its concentration exceeded the IAQ standard. The concentrations of TVOC and PM10 exceeded the standard, by 32% and 24% respectively, whereas those of HCHO and CO were under the standard. HCHO and CO concentrations were under the guideline. 24% of child care centers for education were found to exceed the standard in 2 or more of the pollutants. 82% of were found to exceed the standard by 1 or more. Therefor it is requested for IAQ to manage and improve in child care center for education.

다운대체 아웃도어 재킷의 디자인 개발 (Development of a Down-alternative Outdoor Jacket design)

  • 이달아;문선정;정삼호
    • 복식
    • /
    • 제63권8호
    • /
    • pp.143-155
    • /
    • 2013
  • The outdoor apparel market has been growing very fast recently, and consumers are spending more time doing outdoor activities for their leisure. As the outdoor apparel market is growing, it has started to combine functionality with style to provide more diverse designs and colors for all ages. The increase of interest in heathy life-styles, outdoor activities, and leisure has lead to a rise in demand for outdoor apparel. Now outdoor apparel have become a part of people's daily casual wear in addition to being worn for outdoor activities. This study is focused on a outdoor jacket design which is used as down-alternative material and the purpose of this study is to design outdoor jackets using a down-alternative fabrics that improve the thermal and lightweight effects for clothing comfort, and increase the satisfaction of wearing down-alterative outdoor jacket. The research of this paper was done by using a questionnaire survey. The survey was used to examine the male customers' outdoor activities, purchase behaviors, place, expense and design preferences. Then, down-like fabric was used to make the prototype down jacket and its design, function, and satisfaction with wearing compared with other brands down jacket products were analyzed. Although duck down fabrics are representative of outdoor jackets, they have many problems that need to be solved such as feathers falling out or its vulnerability to moisture. They have competitive prices compared to down jackets so down-alternative jackets are able to gain more proportion of its market share.

주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안 (Operating Mode of Thermally Activated Building System (TABS) for Residential Buildings According to their Cooling Load Profile)

  • 박상훈;여명석;유미혜;이유지;정웅준;김광우
    • 한국주거학회논문집
    • /
    • 제23권2호
    • /
    • pp.99-106
    • /
    • 2012
  • Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due to the time-lag effect of TABS, energy usage can be distributed to other time zones. To maximize this effect, it is important to determine the appropriate operating mode, which for TABS is dependent upon the cooling load generated by the occupancy schedule. In this study, occupancy schedules are determined for various residential types. The operating modes of TABS for these residential types are estimated by using a dynamic computational simulation method. The results indicate that the operating modes of TABS can be determined by residential type and occupancy schedule. The load handled ratio by TABS is set up differently according to the cooling load profile obtained from residential type and occupancy schedule. By using TABS, energy consumption could be reduced by 20% compared to PTAC.

해군 함상 근무복 개발을 위한 착용 실태 조사 (Survey on the Actual Wearing Conditions of Naval Duty Uniforms in Naval Vessels)

  • 이효현;신소라;이주영;백윤정
    • 한국의류산업학회지
    • /
    • 제17권4호
    • /
    • pp.646-656
    • /
    • 2015
  • This study investigates the conditions of Korean naval duty and combat uniforms to develop a new design. Survey participants consisted of, 723 Sailors ($25.3{\pm}6.9yr$ in age, $43{\pm}53$ months in work experience, $174{\pm}6cm$ in height, $71{\pm}9kg$ in body mass) serving in the Korean Navy for over 12 months. The questionnaire consisted of 72 questions about anthropometric characteristics, preferred design, textiles, wear mobility, and subjective perceptions. The results showed that the preferred colors for future naval duty uniforms were blue in summer (69%) and black in winter (62%). Digital camouflage pattern (60%) and darker colors on the inside of shirt collar (87%) and the edge of sleeves (84%) were preferred. They favored more than one pocket on the upper arm and chest of the shirts (58%), narrower width around pant legs and hems than the current clothing (63%), self-controlled elastic waist (55%) and no cargo type pocket on the pants (45%). There were requirements to alleviate excessive heat stress in summer and to protect from the cold and wind in winter. Wrinkle-free (85%), anti-bacterial (78%), water-proof (75%), oil-proof (90%), and elastic (67%) textiles were preferred for Korean navy uniforms. These results will be applied to develop the next generation Korean navy uniforms.

에어컨의 기류 및 온도 변동에 따른 인체 순응에 관한 연구 (Development of Thermal Comfort Sensation in the Variation of Air-velocity and Temperature in Air-conditioner)

  • 장문간;금종수;조관식;이기섭;최광환;정용현;김동규;김형철
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.141-146
    • /
    • 2001
  • 실내 공기조화를 하는 거주역에 대한 온열환경요소의 자극 변화를 통해 실내 에너지를 절약할 수도 있으며 쾌적감도 향상시킬 수 있다. 따라서 본 연구에서는 거주자의 온열감각을 자극할 수 있는 온열요소 중 비교적 영향이 크고 용이하게 제어할 수 있는 온도 및 기류의 변동으로 한국인의 온열감각(온냉감, 쾌적감, 만족감)에 미치는 영향을 실험을 통하여 파악하였다. 온도 및 기류별 실험을 통하여 22$^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$의 각 온도에 대한 패케지 에어컨의 강, 중, 약 기류에 대한 인체순응 시간과 인체 변화를 파악하였다. 또한 인체순응시간을 고려한 온도 상승 실험을 통하여 24$^{\circ}C$, 26$^{\circ}C$에서 1$^{\circ}C$온도 상승시 인체의 온열쾌적감의 변화를 파악하였으며 온도 상승을 통한 인체 순응시간을 도출하였다. 본 실험을 통하여 초기공조 조건을 24C$^{\circ}C$ 로 한 경우 인체순응을 통한 온도 상승으로 30분 후의 공조중기와 공조후기에 온도 및 기류의 지속적인 변동 자극으로 온냉감은 "약간 서늘하다"를 지속적으로 유지하고 있으며 온도상승으로 인한 쾌적존의 높은 온도에서도 기류의 영향으로 쾌적감은 30분 이후부터 "쾌적"을 지속적으로 유지하는 것을 알 수 있었다. 따라서 본 연구를 통하여 인체순응을 고려한 온도 및 기류의 자극을 통하여 공조초기부터 공조말기의 장시간에도 인체가 지속적인 쾌적성을 유지한다는 것을 알 수 있었다.성을 유지한다는 것을 알 수 있었다.

  • PDF

정기적인 찜질 훈련이 청년과 노년여성의 내열성 증진에 미치는 영향 (Effects of Regular Jjimjilbang(Korean sauna) Exposure on Human Heat Tolerance in Young and Old Females)

  • 최정화;송은영;황수경
    • 한국의류학회지
    • /
    • 제31권9_10
    • /
    • pp.1465-1474
    • /
    • 2007
  • We analyzed the effects of regular Jjimjilbang(Korean sauna) exposure on the heat tolerance in young and old females. Subjects were young(n=7) and old(n=7) females who never had a bath in Jjimjilbang for last year. Jjimjilbang training group took a bath in Jjimjilbang once a week 19 times. Jjimjibang expsure was limited three times per day, Jjimjil were taken free way. To prove the effects of the heat tolerance, Subjects were exposed to hot and humid air$(40.0{\pm}0.5^{\circ}C,\;60{\pm}5%RH)$. In the condition, subjects were taken a foot bathing$(40.0{\pm}0.5^{\circ}C)$ and simulated for 30 min., and rectal temperature, skin temperatures, clothing microclimate, blood pressure, total body weight loss, local sweat and subjective sensation were measured. The results are as follow: Rectal temperature, skin temperatures, clothing microclimate, total body weight and subjective thermal comfort sensation were decreased gradually(p<.001). Local sweat of upper arm was decreased(p<.01). In conclusion. the regular Jjimjilbang exposure has positive effects upon improvement in regulation of body temperature, especially in heat tolerance.