• Title/Summary/Keyword: Thermal time constant

Search Result 308, Processing Time 0.03 seconds

Microstructure and Dielectric Properties of (Sr.Ca)$TiO_3$-based Ceramics on the thermal diffusing time (열확산 시간에 따른 (Sr.Ca)$TiO_3$계 세라믹의 미세구조 및 유전특성)

  • Kang, Jae-Hun;Kim, Chung-Hyeok;Song, Min-Jong;Choi, Woon-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1387-1389
    • /
    • 2001
  • In this paper, the microstructure and the dielectric properties of the $Sr_{1-x}Ca_xTiO_3$($0{\leq}x{\leq}0.2$)-based grain boundary layer ceramics were investigated. The 2nd phase formed by thermal diffusing from the surface lead to a very high apparent dielectric constant, ${\varepsilon}_r$ > 50000, and tan$\delta$ < 0.05, $\Delta$C < ${\pm}$ 10%.

  • PDF

Infrared Response Characterization on the Microbolometer Device Design (마이크로볼로미터 소자설계에 따른 적외선 검출특성)

  • Han, Myung-Soo;Ahn, Su-Chang;Kang, Tai-Young;Lim, Sung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.343-344
    • /
    • 2008
  • A surface micromachined uncooled microbolometer based on the amorphous silicon was designed, fabricated, and characterized. We designed the microbolometer with a pixel size of $44\times44{\mu}m^2$ and a fill factor of about 50 % ~ 70% by considering such important factors as the thermal conductance, thermal time constant, the temperature coefficient of resistance, and device resistance. Also, we successfully fabricated the microbolometer by using surface MEMS technology. Finally, we investigated responsivity and detectivity properties depends on the active area size.

  • PDF

Thermal instability of Co-silicides formed by Co and Co/Ti bilayer (Co 및 Co/Ti 이중막에 의해 형성된 Co-실리사이드의 열적 불안정성)

  • 장지근;엄우용;신철상;장호정
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.11
    • /
    • pp.105-111
    • /
    • 1996
  • We have invetigated the characteristics of thermal instability of Co-silicides annealed at 850$^{\circ}$C ~ 1000$^{\circ}$C for 10~90 minutes in a furance with N$_{2}$ ambient. In our experiments, Co-silicides and Co/Ti bilayer silicides were formed by depositing (Co, Ti) films on the clean Si substrates in an E-beam evaporator and performing the RTA annelaing. The sheet resistances of Co-silicides formed form Co exhibited the nearly constant value under the post-annealing time above 900$^{\circ}$C showing the increase of 30% and 60% under the conditions annealed at 900$^{\circ}$C and 1000$^{\circ}$C for 30minutes. On the other hand, there were no remarkable changes in the sheet resistance sof Co-silicides formed form Co/Ti bilayer under the post-annealing conditons below 1000$^{\circ}$C.

  • PDF

Flow Control and Heat Transfer Enhancement from a Heated Block by an Inflow Pulsation (II) Thermal Field Computation (입구 유동 가진에 의한 사각 발열체 주위의 유동제어 및 열전달촉진 (II) 온도장 수치해석)

  • 리광훈;김서영;성형진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.599-606
    • /
    • 2002
  • uniform temperature. The surfaces of the block are taken at a constant higher temperature. The channel walls are assumed to be adiabatic. Results on the time-dependent temperature field are obtained and averaged over a cycle of pulsation. The effect of the important governing parameters, such as the Strouhal number on the flow and the heat transfer is investigated in detail. The results indicate that the recirculating flow behind the block are substantially affected by the pulsation frequency. These, in turn, have a strong influence on the thermal transport from the heated element to the pulsating flow. The frequency at which the enhancement is maximum is determined.

A Study on the Calorific Value of Insulated Gang-form in Winter (동절기 단열갱폼의 발열량 변화 측정에 관한 연구)

  • Kang, In-Seon;Won, Joon-Yuen;Kim, Tae-Hui;Kim, Seong-Deok;Choi, Seok;Nam, Kyung-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.135-136
    • /
    • 2017
  • This paper examines the efficiency of the application of conventional and insulated gang forms for curing and protection of concrete by comparing the amount of electric energy required therefor. In addition, a thermal vision camera was used to identify heat loss from surfaces of the gang forms after each placement of concrete. Experimental results, show that the heat loss at the submerged temperature was large at the submerged surface due to the large calorific value at the surface of the mold. The insulated gang form had some heat loss in the horizontal bars. In the case of adiabatic reforming, the pattern shows a constant calorific value over time. In conclusion, the insulation performance is better than that of general gang form.

  • PDF

Thermoelastic damping in generalized simply supported piezo-thermo-elastic nanobeam

  • Kaur, Iqbal;Lata, Parveen;Singh, Kulvinder
    • Structural Engineering and Mechanics
    • /
    • v.81 no.1
    • /
    • pp.29-37
    • /
    • 2022
  • The present paper deals with the application of one dimensional piezoelectric materials in particular piezo-thermoelastic nanobeam. The generalized piezo-thermo-elastic theory with two temperature and Euler Bernoulli theory with small scale effects using nonlocal Eringen's theory have been used to form the mathematical model. The ends of nanobeam are considered to be simply supported and at a constant temperature. The mathematical model so formed is solved to obtain the non-dimensional expressions for lateral deflection, electric potential, thermal moment, thermoelastic damping and frequency shift. Effect of frequency and nonlocal parameter on the lateral deflection, electric potential, thermal moment with generalized piezothermoelastic theory are represented graphically using the MATLAB software. Comparisons are made with the different theories of thermoelasticity.

Numerical method for Thermal Convection of air in Ondol Room (실내 기류의 수치해석)

  • Min Man-Ki;Kim Joo-Kyoon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.1
    • /
    • pp.4-12
    • /
    • 1978
  • At Grashof numbers $10^{10},\;5{\times}10^{10}$, and $10^{11}$ nonlinear partial differential equations for two dimensional thermal circulation of air in a rectangular enclosure heated from below are solved numerically by finite difference explicit methood in time-dependent form. Two vertical walls and ceiling are held at low temperature and floor at high temperture. Results are compared with From's numerical solutions at $10^9{\lesssim}\;N_{Gr}\;<10^{13}$. The effective draft temperature fields are also obtained to examine cold draft problem, there included a line of constant effective draft temperature $-1.667^{\circ}C$ which is essentially Houghten's $80\%$ comfort data.

  • PDF

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head (스프링클러헤드 감열부의 열적 특성에 관한 연구)

  • You, Woo-Jun;Moon, Hyo-Jun;Youm, Moon-Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.79-84
    • /
    • 2012
  • In this study thermal characteristics of heat-responsive element considering conduction, convection and rate of change of element using Response Time Index (RTI) applied to sensitivity test of sprinkler head at home and aborad are theoretically investigated. Analytic solution of temperature distributions with radial direction and time is obtained form energy transport equations, non-homogeneous 2th order partial differential equation, applying to constant wall temperature and symmetric condition in order to analyze thermal characteristics of heat-responsive element for circular cylindrical geometry. Base on the results, the analytic method of this study is fundamental data to practical use for sensitivity test of sprinkler head and design of heat-responsive element.

Thermal Sensitivity of the Bean Curd by Ultrasonic Irradiation (초음파 조사에 의한 두부의 열 감도)

  • 조문재;윤용현;부유천;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.503-513
    • /
    • 2004
  • In this paper, the thermal sensitivity, i .e. the temperature rise per unit acoustic power, was newly defined and proposed as a performance parameter of a tissue mimicking material. Eatable tofu (bean curd) manufactured by a factory was selected as a sample material for the experiment. The temperature changes were measured not only with the variation of ultrasonic irradiation time, acoustic power, depth from the sample surface. and the distance from the source transducer while adjusting the frequency to 8 MHz but also with the variation of frequency while acoustic power. depth from the sample surface. and the distance from the source transducer keeping constant. As a result of a consideration for the transformation of the measured temperature changes to thermal sensitivities. the thermal sensitivity was found to be sufficient to use as a Performance parameter for tissue mimicking material. The tofu as a tissue mimicking material showed the maximum thermal sensitivity at 10 MHz, as is a significant result to imply the possibility that the thermal sensitivity of real human tissue strong1y depends on the frequency.