A Study on the Calorific Value of Insulated Gang-form in Winter

동절기 단열갱폼의 발열량 변화 측정에 관한 연구

  • 강인선 (대건기술주식회사) ;
  • 원준연 (태영건설) ;
  • 김태희 (목포대학교 건축공학과) ;
  • 김성덕 (국토교통연구인프라운영원) ;
  • 최석 (유탑엔지니어링건축사사무소) ;
  • 남경용 (유탑엔지니어링건축사사무소)
  • Published : 2017.11.16

Abstract

This paper examines the efficiency of the application of conventional and insulated gang forms for curing and protection of concrete by comparing the amount of electric energy required therefor. In addition, a thermal vision camera was used to identify heat loss from surfaces of the gang forms after each placement of concrete. Experimental results, show that the heat loss at the submerged temperature was large at the submerged surface due to the large calorific value at the surface of the mold. The insulated gang form had some heat loss in the horizontal bars. In the case of adiabatic reforming, the pattern shows a constant calorific value over time. In conclusion, the insulation performance is better than that of general gang form.

Keywords