• 제목/요약/키워드: Thermal sensitivity test

검색결과 78건 처리시간 0.021초

민감도 벡터를 이용한 스팀 터빈의 Morton Effect 발생 예측 (Predicting the Morton Effect in a Steam Turbine with Sensitivity Vector)

  • 이동현;김병옥;전병찬;서준호;강신훈;김세룡
    • Tribology and Lubricants
    • /
    • 제40권2호
    • /
    • pp.39-46
    • /
    • 2024
  • The Morton effect (ME) is an instability phenomenon occurring in rotating machineries supported by fluid film bearings and is induced by the thermal deformation of the overhung mass, which is a part of the rotating shaft. Herein, we describe the ME during the high-speed balancing test of a 20 MW class steam turbine. Additionally, to predict the rotating speed at which the ME occurs, we apply the sensitivity vector theory for the steam turbine. During the operation of the steam turbine, we observe a continuous increase in vibration and hysteresis near the rated speed, which is typical of the ME. Increasing the temperature of the lubricating oil supplied to the bearings from 40 to 60℃ suppresses the occurrence of the ME. The rotordynamic analysis for the steam turbine suggests the existence of a mode in which the overhung mass undergoes significant deformation near the rated speed, and we presume that such a mode will increase the occurrence of the ME. The predicted rotating speed of ME occurrence, obtained through the sensitivity vector method, correlates with the test results. Moreover, increasing the temperature of the supplied lubricating oil mitigates the occurrence of ME by reducing the sensitivity between the temperature deviation vector and unbalance mass vector.

Decreased Pain Sensitivity of Capsaicin-Treated Rats Results from Decreased VR1 Expression

  • Lee, Soon-Youl;Hong, Young-Mi;Oh, Uh-Taek
    • Archives of Pharmacal Research
    • /
    • 제27권11호
    • /
    • pp.1154-1160
    • /
    • 2004
  • We investigated the neurotoxic effects of capsaicin (CAP) on pain sensitivity and on the expression of capsaicin receptor, the vanilloid receptor (VR1), in rats. High-dose application of CAP has been known to degenerate a large fraction of the sensory neurons. Although the neurotoxic effects of CAP are well documented, the effects of CAP on the vanilloid receptor (VR1) are not yet known. In this paper, we investigated the effects of high-dose application of CAP on the expression of VR1 in rats. Thermal and mechanical pain sensitivity was reduced when neonatal rats were treated with a high dose of CAP. This reduction of pain sensitivity was significantly decreased after initiating carrageenan-induced inflammation. The expression of VR1 in dorsal root ganglia (DRG) isolated from the CAP-treated rats was reduced compared to that from the vehicle-treated rats. Therefore, we can conclude that the neurotoxic effect of CAP is related to the decrease of VR1 expression.

Forced-air Warming System을 이용한 수술 전 가온이 복부 수술 환자의 체온, 불안, 통증 및 온도 편안감에 미치는 효과 (The Effect of Pre-warming for Patients under Abdominal Surgery on Body Temperature, Anxiety, Pain, and Thermal Comfort)

  • 박옥분;최희정
    • 대한간호학회지
    • /
    • 제40권3호
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effect of pre-warming on body temperature, anxiety, pain, and thermal comfort. Methods: Forty patients who were scheduled for abdominal surgery were recruited as study participants and were assigned to the experimental or control group. For the experimental group, a forced air warmer was applied for 45-90 min (M=68.25, SD=15.50) before surgery. Body temperature and anxiety were measured before and after the experiment, but pain and thermal comfort were assessed only after the surgery. Hypotheses were tested using t-test and repeated measured ANOVA. Results: The experimental group showed higher body temperature than the control group from right before induction to two hours after surgery. Post-operative anxiety and pain in the experimental group were less than those of the control group. In addition, the score of thermal comfort was significantly higher in the experiment group. Conclusion: Pre-warming is effective in maintaining body temperature, lowering sensitivity to pain and anxiety, and promoting thermal comfort. Therefore, pre-warming can be recommended as a preoperative nursing intervention.

웹기반 체온 관리 근거중심 간호실무 가이드라인이 위절제술 환자의 체온, 전율, 체온 불편감, 체온 관리 만족도에 미치는 효과 (Use of Web-Based Evidence-based Clinical Practice Guidelines for Patients following Gastrectomy: Effects on Body Temperature, Shivering, Perceived Thermal Comfort, and Satisfaction with Temperature Management)

  • 홍성정;이은주
    • 기본간호학회지
    • /
    • 제21권2호
    • /
    • pp.112-122
    • /
    • 2014
  • Purpose: The purpose of this study was to examine the effects on body temperature, shivering, and perceived thermal comfort of web-based evidence-based practice guideline for patients undergoing gastrectomy. Methods: Eighty patients scheduled for gastrectomy were recruited and assigned to the control or experimental group by sequential order. Before collecting data from the experimental group, a systematic educational program on evidence-based guidelines was provided to the nurses as well anesthesiologists. Data were analyzed using t-test and repeated measured ANOVA. Results: The experimental group showed higher body temperature from the induction of anesthesia until four hours after surgery compared to the control group. In addition, the levels of thermal comfort as well as satisfaction with thermal management were significantly higher in the experiment group. Conclusion: Use of evidence-based guidelines was effective in maintaining body temperature, lowering sensitivity to shivering, and promoting perceived thermal comfort. Therefore, adoption of evidence-based interventions in nursing practice is recommended.

상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구 (Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus)

  • 이진성;김경수;김유일;우석민;윤승진
    • 한국해양공학회지
    • /
    • 제29권2호
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.

FC-BGA C4 bump의 신뢰성 평가에 따른 파괴모드 연구 (The Effect of Reliability Test on Failure mode for Flip-Chip BGA C4 bump)

  • 허석환;김강동;장중순
    • 마이크로전자및패키징학회지
    • /
    • 제18권3호
    • /
    • pp.45-52
    • /
    • 2011
  • Flip Chip Ball Grid Array (FCBGA) 패키지의 솔더조인트 신뢰성을 평가하기 위한 방법으로는 다이 충격법, 다이 전단법, 3점 굽힘법, 열충격법 등이 활용된다. 본 연구에서는 솔더 접합부의 주요 고장메카니즘인 취성파괴를 확인하기 위한 방법으로 리플로우 상태, $85^{\circ}C$/85%RH 처리, $150^{\circ}C$/10hr 에이징의 처리한 후, 4가지 평가법으로 평가를 진행하여 파단모드를 분석하였다. 본 연구결과에서는 다이 충격법과 다이 전단법의 Good joint rate (GJR, %)는 리플로우 상태와 $85^{\circ}C$/85%RH처리에서 각각 89~91%와 100% 였으며, $150^{\circ}C$/10hr 에이징에서는 66%와 90%를 나타내었다. 3점 굽힘법과 열충격법의 GJR(%)는 3종류 샘플에서 모두 100%를 나타내어 변별력이 없었다. C4 솔더접합부의 신뢰성 평가법에 따른 GJR(%)의 변별력을 확인할 수 있는 방법은 die shock 과 die shear test였다.

범프 본딩된 압저항 실리콘 가속도센서의 제조 (Fabriaction of bump bounded piezoresistive silicon accelerometer)

  • 심준환;이상호;이종현
    • 전자공학회논문지D
    • /
    • 제34D권7호
    • /
    • pp.30-36
    • /
    • 1997
  • Bump bonded piezoesistive silicon accelerometer was fabricated by the porous silicon micromachining and th eprocess technique of integrated circuit. The output voltage of the accelerometer fabricated on (111)-oreiented Si substrates with n/n$^{+}$n triple layers showed good linear characteristic of less than 1%. The measured sensitivity and the resonant frequency was about 743 .mu.V/g and 2.04 kHz, respectively. And the transverse sensitivity of 5.2% was measured from the accelerometer. Also, to investigate an influence on the output characteristics of the sensor due to bump bonding, the values of the piezoresistors were measured through thermal-cycling test in the temperature variation form -50 to 120.deg. C. Then, there was 0.014% resistance changes about 3.61 k.ohm., so sthe output charcteristics of the sensor was less affected by bump bonding.g.

  • PDF

초정밀 열 영상 현미경 광학계 개발 (Development of the Ultra Precision Thermal Imaging Optical System)

  • 양순철;원종호
    • 한국정밀공학회지
    • /
    • 제27권12호
    • /
    • pp.15-21
    • /
    • 2010
  • Recently, there is a demand for a thermal imaging microscope in the medical field as well as the semi-conductor industry Although the demand of the advanced thermal imaging microscope has been increased, it is very difficult to obtain the technology of developing a thermal camera, because it is used for defense industry. We developed the ${\times}5$ zoom microscope which has $3\;{\mu}m$ spatial resolution to research the design and fabrication of the IR (Infrared) optical system. The optical system of the IR microscope consists of four spherical lenses and four aspheric lenses. We verified individual sensitivity of each optical parameter as the first order approach to the analysis. And we also performed structure and vibration analysis. The optical elements are fabricated using Freeform 700A. The measurement results of surface roughness and form accuracy using NT 2000 and UA3P are Ra 2.36 nm and P-V $0.13\;{\mu}m$. Finally we ascertained resolution power of $3\;{\mu}m$ using USAF (United State Air Force) 1951 IR resolution test chart.

PARAMETRIC STUDIES ON THERMAL HYDRAULIC CHARACTERISTICS FOR TRANSIENT OPERATIONS OF AN INTEGRAL TYPE REACTOR

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Song, Chul-Hwa;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.185-194
    • /
    • 2006
  • Transient operations for an integral type reactor, SMART-P, have been experimentally investigated using a thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), in order to verify the system design and performance of the SMART-P, a pilot plant of SMART. The VISTA facility was subjected to various accident conditions such as feedwater increase and decrease, loss of coolant flow, and control rod withdrawal accidents in order to elucidate the thermal-hydraulic responses following such accidents and finally to verify the system design of the SMARTP. Full functional control logics have been implemented in the VISTA facility in order to control the required control action for an accident simulation. As one of the sensitivity tests to verify the PRHRS performance, the effects of the initial water level in the compensation tank are experimentally investigated. When the initial water level is 16%, the water is quickly drained and nitrogen gas is then introduced into the PRHR system, resulting in deterioration of the PRHRS performance. It is thus found that nitrogen ingression should be prevented to ensure stable PRHRS operation.

ROSA/LSTF test and RELAP5 code analyses on PWR steam generator tube rupture accident with recovery actions

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.981-988
    • /
    • 2018
  • An experiment was performed for the OECD/NEA ROSA-2 Project with the large-scale test facility (LSTF), which simulated a steam generator tube rupture (SGTR) accident due to a double-ended guillotine break of one of steam generator (SG) U-tubes with operator recovery actions in a pressurized water reactor. The relief valve of broken SG opened three times after the start of intact SG secondary-side depressurization as the recovery action. Multi-dimensional phenomena specific to the SGTR accident appeared such as significant thermal stratification in a cold leg in broken loop especially during the operation of high-pressure injection (HPI) system. The RELAP5/MOD3.3 code overpredicted the broken SG secondary-side pressure after the start of the intact SG secondary-side depressurization, and failed to calculate the cold leg fluid temperature in broken loop. The combination of the number of the ruptured SG tubes and the HPI system operation difference was found to significantly affect the primary and SG secondary-side pressures through sensitivity analyses with the RELAP5 code.