공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구 (A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses)

  • 조영욱;박선효;정광섭
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

동계 아파트 외표면 온도에 의한 단열성능 비교평가 (Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation)

  • 박정훈;김봉주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.91-100
    • /
    • 2013
  • 이 연구에서는 기존아파트 외벽체의 단열 성능저하 및 보수보강에 필요한 기초 자료를 만들기 위해서 아파트의 구조체 단열성능 측정분석과 함께 단열하자에 대한 기준수립 및 평가를 하고자 한다. 또한 아파트 건축물 구조체의 열교 및 결로발생 부분을 예측하고자 하였다. 한편 시공연도별 분석에 의하여 단열기준 및 시간 경과에 따른 단열성능 정도를 분석하기 위함이다.

단열 보완형 복합방수공법의 단열성능에 관한 연구 (Thermal Insulation Performance of Composite Waterproofing Method of Thermal Supplement Type)

  • 최성민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.59-66
    • /
    • 2014
  • 건설구조물 상부의 단열은 에너지 절약 건설구조물에 있어서 중요한 요건 중 하나이다. 건설구조물 최상부는 단열성뿐만 아니라 방수성능도 중요하다. 이와 같은 이유로 단열성을 확보한 방수공법의 개발이 요구된다. 본 연구에서는 최근 일정 단열성능을 확보한 단열 보완형의 복합방수공법이 개발되어 해당 공법에 대한 단열성능을 평가하고자 하였다. 방수성 시험결과, 모든 시험체는 KS 표준 이상의 성능을 보여주었다. 단열성 시험결과, 스티로폼 박스가 가장 높은 온도인 $25.91^{\circ}C$, 버블시트 박스가 $17.28^{\circ}C$, 단열시트 박스가 $15.47^{\circ}C$, 단열보완형 방수시트가 $24.11^{\circ}C$로 확인되었다. 시트 접합부의 열교현상을 관찰한 결과 열교현상은 발생하지 않았다. 단열보완형 복합방수공법은 단열성능을 확보하고 있는 것으로 판단된다.

공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구 ((A)Study on Apartment Insulation Status and Insulation reinforcement Application)

  • 정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구 (A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer)

  • 박동소
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5284-5289
    • /
    • 2011
  • 본 연구에서는 대학 캠퍼스의 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열관류율(U-value) 평가를 수행하였다. 교육시설의 주요 창호 재료로 적용된 알루미늄은 열전도율이 175 $kca{\ell}/m^2h^{\circ}C$ 정도로 플라스틱 소재의 창틀과 비교할 때, 매우 불리하여 기존 교육시설에 설치된 알루미늄 창호는 열교를 통한 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 알로이 합금 창호의 열관류율 평가에 관한 연구를 수행하여 다음의 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물 에너지절약설계기준의 남부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 시물레이션을 통한 해석 결과 열관류율은 알루미늄 합금 창호 U= 9.631 W/$m^2K$, 복층유리 U= 2.382 W/$m^2K$로 여름철과 겨울철 동일한 해석 결과치가 산출되었다. (2) 열관류율 해석결과를 "건축물의 에너지절약설계기준"의 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반 복층창 단열성능기준인 U=4.0 W/$m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열손실이 발생됨을 보여 주고 있다.

건축용 단열재의 장기 경시변화에 따른 열성능 특성 (The Thermal Performance of Building Insulation Materials According to Long-Term Aging)

  • 최보혜;강재식
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.617-623
    • /
    • 2013
  • This study is to draw thermal property data during long-term aging, by testing the thermal conductivity of building insulation materials in Korea. The thermal resistance of extruded insulation within 3 days from manufacture performed well over the KS Standard. After 50 to 110 days, however, the thermal performance had deteriorated to the level of the KS standard. Eventually, after 4,000 days, the insulation performance had deteriorated to about 25.4~41.8% of the initial performance. Therefore, this research will be utilized as a reference for thermal properties during long-term aging, in order to improve standards and regulations related to building insulation materials.

주택에서의 단열성능 강화가 냉난방부하에 미치는 영향 (The Strengthening Effect of the Heating and Cooling Load on the Thermal Performance in the Housing Unit)

  • 이준기;김성훈;이갑택;이경희
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.483-488
    • /
    • 2016
  • In this study, we chose the rural house as a standard model. In order to review the energy difference of cooling and heating loads, we changed the thermal transmittance standards. By using the thermal transmittance standard in 2011 as the Basic CASE, the thermal transmittance standard in 2013 as well as 2016, and the thermal transmittance standard of passive houses, we compared the results with regard to the cooling and heating energy load. Because of the heat loss, it can be confirmed that with an improved thermal performance of the building structure, the maximum increase of the cooling energy load was 36 kWh from June to September. Because of the heat loss, it was also confirmed that with the improved thermal performance of a building structure, the maximum decrease of the heating energy load is 1,498 kWh from November to April. Even though the heat loss of the building structure could decrease the cooling energy load by improving thermal transmittance standards in Korea, the energy saving performance is worse than the situation of heating energy load in heating period. Compared with CASE 1 and CASE 2, as well as CASE 1 and CASE 3, we CASE 3 was found to have the best energy saving rate when compared to the other cases : CASE 3 increased by 1,452 kWh and CASE 2 by 588 kWh, because the window thermal transmittance standard of 2016 was added.

흡착포집 및 열탈착/GC 분석에 의한 공기 중 휘발성 유기화합물의 측정방법론 평가 (Evaluation of Methodology for the Measurement of VOCs in the Air by Adsorbent Sampling and Thermal Desorption with GC Analysis)

  • 백성옥;황승만;박상곤;전선주;김병주;허귀석
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.121-138
    • /
    • 1999
  • This study was carried out to evaluate the performance of a sampling and analytical methodology for the measurement of selected volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/FID and GC/MSD analysis. Target analytes were aromatic VOCs, including BTEX, 1,3,5-and 1,2,4,-trimethylbenzenes(TMBs), and naphthalene. The methodology was investigatedwith a wide range of performance criteria such as repeatability, linearity, lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal and external standards. standards. Stability of samples collected on adsorbent tubes during storage was also investigated. In addition, the sampling and analytical method developed during this study was applied to real samples duplicately collected in various indoor and outdoor environments. Precisions for the duplicate samples and distributed volume samples appeared to be well comparable with the performance criteria recommended by USEPA TO-17. The audit accuracy was estimated by inter-lab comparison of both duplicate samples and standard materials between the two independent labs. The overall precision and accuracy of the method were estimated to be within 30% for major aromatic VOCs such as BTEX. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

  • PDF

초음파 열지수 측정용 조직모사 물질의 성능계수 (Performance Parameter of Tissue Mimicking Material measuring Ultrasonic Thermal Index)

  • 김용태;조문재;윤용현;김호철
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.369-370
    • /
    • 2004
  • 초음파의 조차에 의한 인체내부의 온도상승의 측도로 열지수(thermal index)가 사용되고 있으며, 이는 주파수 및 음향파워에 의존한다. 초음파 조사에 의한 인체내부의 온도상승을 평가하는데 사용되는 재료를 조직 모사 물질이라 한다. 본 논문아사는 단위 음향파워에 대한 온도 변화인 열 감도(thermal sensitivity)를 새로이 정의하였으며, 이 물리량으로 조직모사물질의 성능을 평가 할 수 있다는 것을 제안하고자 한다.

  • PDF

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.