The Thermal Performance of Building Insulation Materials According to Long-Term Aging  

Choi, Bo-Hye (Green Building Research Division, Korea Institute of Construction Technology)
Kang, Jae-Sik (Green Building Research Division, Korea Institute of Construction Technology)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.25, no.11, 2013 , pp. 617-623 More about this Journal
Abstract
This study is to draw thermal property data during long-term aging, by testing the thermal conductivity of building insulation materials in Korea. The thermal resistance of extruded insulation within 3 days from manufacture performed well over the KS Standard. After 50 to 110 days, however, the thermal performance had deteriorated to the level of the KS standard. Eventually, after 4,000 days, the insulation performance had deteriorated to about 25.4~41.8% of the initial performance. Therefore, this research will be utilized as a reference for thermal properties during long-term aging, in order to improve standards and regulations related to building insulation materials.
Keywords
Thermal conductivity; Thermal resistance; Insulation materials; Long-term aging;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kang, J. S., 2005, An experimental study on the thermal conductivity change of building insulation materials with long-time elapse III, an Journal of Architectural Institute of Korea, Vol. 25, No. 1, pp. 163-166.
2 Jeong ,Y. S., 2002, An experimental study on the thermal conductivity change of building insulation materials with long-time elapse, an Journal of Architectural Institute of Korea, Vol. 22, No. 1, pp. 485-488.
3 Ministry of Land, Infrastructure and Transport, 2013, Building energy saving design standards.
4 KS M ISO 11561 : 2009 Aging of thermal insulation materials-Determination of the long-term change in thermal resistance of closed-cell plastics(accelerated laboratory test methods).
5 ASTM C1104(Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation).
6 KS M 3808 : 2011 Cellular polystyrene(PS) for thermal insulation.
7 KS M 3809 : 2006 Rigid polyurethane foam for thermal insulation.
8 KS L 9016 : 2010 Test methods for thermal transmission properties of thermal insulations.
9 Choi, H. J., 2003, An experimental study on thermal conductivity change of building insulation materials with long-time elapse II, an Journal of Architectural Institute of Korea, Vol. 23, No. 1, pp. 605-608.