• Title/Summary/Keyword: Thermal expansion data

Search Result 162, Processing Time 0.024 seconds

원자로 냉각재 계통을 지지하는 대구경 유압식 스너버의 이동거리 해석 (Stroke Analysis of Large Bore Hydraulic Snubber Supporting Reactor Coolant System)

  • 이상호;윤기석;전장환;박명규;엄세윤
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.61-67
    • /
    • 1995
  • The steam generator, one of the major components in the reactor coolant system, plays an important role in transferring the thermal energy made in the reactor during normal operation to the secondary side and producing steam to drive turbine. A hydraulic snubber system is used in order to protect the steam generator under the dynamic loading condition and to absorb the thermal expansion transmitted by the reactor coolant piping due to high temperature and pressure during normal operation. In this study, the model for a geometrical linkage system is presented to analyze the snubber stroke of the steam generator and the parameters in the snubber stroke analysis are investigated. A method to analyze lever ratio of the linkage system which is required in the process of determining the snubber stiffness value is also presented. To discuss the validation of the suggested analysis, the analysis results are compared with the measured data during the hot functional test for the standardized 1000 Mwe pressurized water reactor plant under the construction.

  • PDF

온라인 웹기반 원전 터빈 사이클 열성능 분석 시스템 (Web-Based On-Line Thermal Performance Analysis System for Turbine Cycle of Nuclear Power Plant)

  • 최기상;최광희;지문학;홍승열;김성근
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.409-416
    • /
    • 2005
  • We need to develop a on-line thermal performance analysis system for nuclear power plant to determine performance status and heat rate of turbine cycle. We have developed PERUPS(PERformance Upgrade System) to aid the effective performance analysis of turbine cycle. Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on PTC(Performance Test Code). Robustness in the on-line performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful web interfaces for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis report. The system was successfully applied for YongGwang nuclear plant unit #3,4.

3D 스캔을 이용한 실리콘 태양전지의 휨 현상 측정 연구 (Measurement of Bow in Silicon Solar Cell Using 3D Image Scanner)

  • 윤필영;백태현;송희은;정하승;신승원
    • 대한기계학회논문집B
    • /
    • 제37권9호
    • /
    • pp.823-828
    • /
    • 2013
  • 실리콘 태양전지의 두께를 줄일 경우 여러 문제점이 발생하게 되는데 그 중에서 태양전지의 휨 현상은 제품 수율의 직접적인 원인이 되어 제품 상용화에 가장 큰 걸림돌이 되고 있다. 본 연구에서는 태양전지의 실리콘 웨이퍼 두께를 가변하였을 때의 휨 정도에 대해 정밀하게 측정하고자 하였다. 측정결과의 신뢰성을 높이고 비 대칭성 형상에 대해 자세하고 정밀하게 분석하기 위해 3D 이미지 스캐너를 사용하였다. 그 결과 실리콘 웨이퍼의 두께가 감소할수록 휨 정도는 급격하게 증가하고 곡률 또한 증가하는 것을 확인할 수 있었다. 실리콘 웨이퍼의 두께가 감소할 수록 휨 정도의 편차가 증가하여 형상의 비 대칭성이 증가하는 것 또한 확인되었다. 또한 Ag 전극의 부착이 휨 현상을 어느 정도 감소시키는 것을 알 수 있었다.

Effects of the electronic expansion valve and variable velocity compressor on the performance of a refrigeration system

  • Lago, Taynara G.S.;Ismail, Kamal A.R.;Nobrega, Claudia R.E.S.;Moura, Luiz F.M.
    • Advances in Energy Research
    • /
    • 제7권1호
    • /
    • pp.1-19
    • /
    • 2020
  • Energy consumption of air-conditioning and refrigeration systems is responsible for about 25 to 30% of the energy demand especially in hot seasons. This equipment is mostly electricity dependent and their use in principle affects negatively the environment. Enhancing the energy efficiency of the existing equipment is important as one of the measures to reduce environment impacts. This paper reports the results of an experimental study to evaluate the impacts of the use electronic expansion valve and variable velocity compressor on the performance of vapor compression refrigeration system. The experimental rig is composed of two independent circuits one for the vapor compression system and the other is the secondary fluid system. The vapor compression system is composed of a forced air condenser unit, evaporator, hermetic compressor and expansion elements, while the secondary system has a pump for circulating the secondary fluid, and an air conditioning heat exchanger. The manufacturer's data was used to determine the optimal points of operation of the system and consequently tests were done to evaluate the influence of variation of the compressor velocity and the opening of the expansion device on the performance of the refrigeration system. A fuzzy logic model was developed to control the rotational velocity of the compressor and the thermal load. Fuzzy control model was made in LabVIEW software with the objective of improving the system performance, stability and energy saving. The results showed that the use of fuzzy logic as a form of control strategy resulted in a better energy efficiency.

72.5 Ah NCM계 파우치형 리튬이온배터리의 표면온도 상승률이 열폭주 발생시간에 미치는 영향 분석 (Analysis of Effect of Surface Temperature Rise Rate of 72.5 Ah NCM Pouch-type Lithium-ion Battery on Thermal Runaway Trigger Time)

  • 이흥수;홍성호;이준혁;박문우
    • 한국안전학회지
    • /
    • 제36권5호
    • /
    • pp.1-9
    • /
    • 2021
  • With the convergence of the information and communication technologies, a new age of technological civilization has arrived. This is the age of intelligent revolution, known as the 4th industrial revolution. The 4th industrial revolution is based on technological innovations, such as robots, big data analysis, artificial intelligence, and unmanned transportation facilities. This revolution would interconnect all the people, things, and economy, and hence will lead to the expansion of the industry. A high-density, high-capacity energy technology is required to maintain this interconnection. As a next-generation energy source, lithium-ion batteries are in the spotlight today. However, lithium-ion batteries can cause thermal runaway and fire because of electrical, thermal, and mechanical abuse. In this study, thermal runaway was induced in 72.5 Ah NCM pouch-type lithium-ion batteries because of thermal abuse. The surface of the pouch-type lithium-ion batteries was heated by the hot plate heating method, and the effect of the rate of increase in the surface temperature on the thermal runaway trigger time was analyzed using Minitab 19, a statistical analysis program. The correlation analysis results confirmed that there existed a strong negative relationship between each variable, while the regression analysis demonstrated that the thermal runaway trigger time of lithium-ion batteries can be predicted from the rate of increase in their surface temperature.

가교량의 온도응력 평가 (Assessment of Thermal Stress in Temporary Bridge)

  • 박영훈;이승용;변윤주;장동일
    • 한국강구조학회 논문집
    • /
    • 제10권1호통권34호
    • /
    • pp.1-10
    • /
    • 1998
  • 교량의 신설 또는 보수를 위한 작업차량의 진출입로나 기존 통행차량의 우회를 목적으로 한시적으로 사용되는 가교량은 일반적으로 상부구조로 H-Beam, 하부구조로 H-Pile을 사용하여, 이들 각 부재를 고장력볼트로 연결한 강구조 형식을 채택하고 있다. 그러나 이러한 교량은 상부구조에 신축이음부를 두지 않고 있어 일일기온차에 의해 발생하는 온도응력이 전체 구조거동에 미치는 영향이 클 것으로 예상된다. 따라서, 본 연구에서는 상부구조인 H-Beam에 온도와 변형률의 상시계측을 위한 모니터링 시스템을 도입하여 측정된 온도 및 변형률 데이터로부터 발생온도와 온도응력의 관계를 조사하였으며, 구조해석을 통한 이론치와의 비교를 실시하여 각 부재에서 발생하는 온도응력이 전체 구조거동에 미치는 영향을 평가하였다. 그 결과, 본 구조물에서 발생하는 응력의 변화는 부재의 온도변화에 의한 온도응력이 주원인인 것으로 나타났으며, 하부구조인 H-Pile의 충분한 교축방향 변위로 인하여 상부구조인 H-Beam의 온도변형 구속은 이루어지지 않는 것으로 나타났다. 한편, 상부구조인 H-Beam간의 연결 강성이 충분하지 않아 전체 구조계보다는 부분 구조계에 대한 해석으로부터 얻어진 변형량이 측정 온도 및 응력으로부터 계산된 변형량과 잘 일치하는 것으로 나타났다.

  • PDF

고속철도 교량상 장대레일의 하절기 온도응력 계측 (Field Test to Investigate the Thermal Stress of Continuous Welded Rail on High Speed Railway Bridges in Summer Period)

  • 곽종원;최은석;진원종;이정우;김병석;강재윤
    • 한국철도학회논문집
    • /
    • 제9권2호
    • /
    • pp.131-136
    • /
    • 2006
  • Most modern railways, especially the high speed railway tracks, use continuous welded rail(CWR) for the less maintenance. For the CWR track has very few expansion joints, track buckling has always been an unpredictable event and it happens mainly by high compressive stress in rail in summer period. Therefore, it is important to understand the variation of rail stress induced by thermal loads which has direct influence on the rail buckling and stability of railway track. This paper describes the experimental investigation of the variation of rail temperature and stress in a high speed railway track on bridge structure. Field measurement was performed to examine the correlation between the rail temperature and rail stress on the Korean High Speed Railway line. Regression functions were derived from measured data to determine the rail stress f3r an arbitrary rail temperature varies from 20 to 50 degree Celsius.

고분자 전해질 연료전지 막의 변형 및 피로수명 (Study for the Deformation and Fatigue Life of a PEMFC)

  • 양정환;박정선
    • 한국항공우주학회지
    • /
    • 제39권5호
    • /
    • pp.400-407
    • /
    • 2011
  • 전해질 막의 응력 및 변화폭의 분포는 고분자 전해질 연료전지 (PEMFC, Polymer Electrolyte Membrane Fuel Cell)의 피로수명의 중요한 인자이다. 본 논문에서는 연료전지 운전조건의 hygro-thermal 조건에 의해 전해질 막에 발생하는 기계적 응력 해석을 모델링 하였다. 기체확산층과 전해질 막 사이의 접촉해석이 여러 가지 온도, 습도 조건에 대하여 수행되었다. 구조 모델은 온도와 상대습도에 의존하는 비선형 재료물성을 적용하였다. 몇 가지 기하학적 조건들이 모델에 적용되었다. 구조해석 결과는 전해질 막의 변형이 체결조건에 크게 의존함을 보여주었다. 실험 데이터와의 비교를 통해 운전 조건에 대하여 피로수명 예측이 수행되었다.

An Experimental Investigation of Direct Condensation of Steam Jet in Subcooled Water

  • Kim, Yeon-Sik;Chung, Moon-Ki;Park, Jee-Won;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.45-57
    • /
    • 1997
  • The direct contact condensation phenomenon, which occurs when steam is injected into the subcooled water, has been experimentally investigated. Two plume shapes in the stable condensation regime are found to be conical and ellipsoidal shapes depending on the steam mass flux and the liquid subcooling. Divergent plumes, however, are found when the subcooling is relatively small. The measured expansion ratio of the maximum plume diameter to the injector inner diameter ranges from 1.0 to 2.3. By means of fitting a large amount of measured data, an empirical correlation is obtained to predict the steam plume length as a function of a dimensionless steam mass flux and a driving potential for the condensation process. The average heat transfer coefficient of direct contact condensation has been found to be in the range 1.0~3.5 ㎿/$m^2$.$^{\circ}C$. Present results show that the magnitude of the average condensation heat transfer coefficient depends mainly on the steam mass fin By using dynamic pressure measurements and visual observations, six regimes of direct contact condensation have been identified on a condensation regime map, which are chugging, transition region from chugging to condensation oscillation, condensation oscillation, bubbling condensation oscillation, stable condensation, and interfacial oscillation condensation. The regime boundaries are quite clearly distinguishable except the boundaries of bubbling condensation oscillation and interfacial oscillation condensation.

  • PDF

Pilot LNG저장탱크 멤브레인 실 변형 거동 측정 (The Measurement of Real Deformation Behavior in Pilot LNG Storage Tank Membrane)

  • 김영균;윤인수;오병택;홍성호;양영명;김정규
    • 한국가스학회지
    • /
    • 제9권3호
    • /
    • pp.27-31
    • /
    • 2005
  • LNG 저장탱크 내부에 설치되는 멤브레인은 LNG 저장시 발생하는 온도와 압력의 하중변화에 따른 열수축과 팽창을 주름에서 흡수하도록 설계 되어있다 따라서 멤브레인 주름부의 변형률 측정을 통한 성능평가가 중요하며 이를 위해 유한요소해석 및 실험을 수행한다. 스트레인 게이지를 이용한 응력측정 시스템을 구축하여 운전 상태에서 멤브레인 주름 거동을 파악하기 위하여 변형률을 측정하였다. 일부 측정값을 유한요소해석에 의해 구한 결과와 비교하여 KOGAS 멤브레인의 특성을 검토하였다.

  • PDF