• 제목/요약/키워드: Thermal difference

검색결과 2,304건 처리시간 0.031초

도재소부전장금관용 Opaque 분말과 도재전장관용 core 분말의 물리화학적 성질 및 금속과의 결합력에 대한 비교연구 (A COMPARATIVE STUDY OF THE PHYSICOCHEMICAL PROPER TIES AND BOND STRENGTH TO METAL BETWEEN THE REGULAR OPAQUE POWDER AND CORE POWDER)

  • 임장섭;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.144-164
    • /
    • 1997
  • The purpose of this study were to investigate the chemical composition, mean particle size, linear thermal expansion coefficient and metal-bonding strength of the regular opaque powder and core powder. In this study, 4 types of ceramic powders, namely Duceram Jacket Opaque powder, Duceram Opaque powder, Vita Hi-Ceram powder, Vita VMK Paint On-88 powder were used. Chemical composition was evaluated by EDS(Energy Dispersive X-ray Spectrophotometer, Oxford QX-2000, England), particle size was measured by MALVERN Instruments(MALVERN Instruments SB. OC., U.S.A.. ad linear thermal expansion coefficient was measured by dilatometer(Motoyama, Japan). Bond strength was measured by the Universal tsting machine(Istron Co., Ltd., U.S.A.). The Results were as follows : 1. Through recognition of the relative difference in chemical composition between the core powder and the regular opaque powder, the difference in the proportion of $Al_2O_3$ in each type of material is demonstrated ; Duceram Jaket Opaque powder : 30.16%, Duceram Opaque powder : 16.60%, Vita Hi-Ceram : 63.64%, Vita VMK Paint-On 88 : 16.16%. 2. There was no significant difference in the proportion of metal-bonding materials between the core powder and the regular opaque powder. 3. In the regular opaque powder, alkaline materials were incoporated in order to increase the coefficient of thermal expansion. 4. In the particle size analysis, there was no significant difference in mean particle size or in the particle size distribution between the core powder and the regular opaque powder. 5. In the thermal expansion test for temperature range of $25-600^{\circ}C$, the regular opaque powder had higher coefficient of thermal expansion than that of core powder. 6. In the 4 point flexural bending test, there was no statistically significant difference in the mean bond strength between the core powder and the opaque powder among the Duceram products.

  • PDF

적외선열화상카메라의 응답 및 노이즈 특성 평가 (Responsivity and Noise Evaluation of Infrared Thermal Imaging Camera)

  • 김동익;김기석;김건희;장기수
    • 비파괴검사학회지
    • /
    • 제33권4호
    • /
    • pp.342-348
    • /
    • 2013
  • 본 논문에서는 비접촉 비파괴검사에 사용되는 적외선열화상카메라의 응답 및 노이즈 특성을 평가할 수 있는 방법을 제시하고 있으며 차동모드흑체의 적외선 표적과 그 주변의 온도차 ${\Delta}$T를 이용하여 상용 적외선열화상카메라의 신호전달함수 및 온도분해능을 구하고 그 결과를 카메라 사양과 비교함으로써 본 평가 방법의 적합성을 검증하였다. 또한 비균일성 보정의 적용 유무로부터 나타나는 온도분해능의 차이 0.01 K을 통하여 적외선열화상카메라의 성능평가에 있어서 비균일성 보정이 필수적인 과정임을 확인하였다.

Thermal field of large-diameter concrete filled steel tubular members under solar radiation

  • Yang, Daigeng;Chen, Guorong;Ding, Xiaofei;Xu, Juncai
    • Computers and Concrete
    • /
    • 제26권4호
    • /
    • pp.343-350
    • /
    • 2020
  • Concrete-filled steel tubular (CFST) members have been widely used in engineering, and their tube diameters have become larger and larger. But there is no research on the thermal field of large-diameter CFST structure. These studies focused on the thermal field of the large-diameter CFST structure under solar radiation. The environmental factors and the actual placement position were considered, and the finite element model (FEM) of the thermal field of CFST members under solar radiation (SR) was established. Then the FEM was verified by practical experiments. The most unfavorable temperature gradient model in the cross-section was proposed. The testing results showed that the temperature field of the large-diameter CFST member section was non-linearly distributed due to the influence of SR. The temperature field results of CFST members with different pipe diameters indicated that the larger the core concrete diameter was, the slower the central temperature changed, and there was a significant temperature difference between the center and the boundary. Based on the numerical model, the most unfavorable temperature gradient model in the section was proposed. The model showed that the temperature difference around the center of the circle is small, and the boundary temperature difference is significant. The maximum temperature difference is 15.22℃, which appeared in the southern boundary area of the specimen. Therefore, it is necessary to consider the influence of SR on the thermal field of the member for large-diameter CFST members in actual engineering, which causes a large temperature gradient in the member.

Low Thermal Expansion of $Al_2TiO_5$ Ceramics Prepared from Electrofused Powders

  • Kim, Ik-Jin;Kwak, Hyo-Sup
    • The Korean Journal of Ceramics
    • /
    • 제5권4호
    • /
    • pp.414-418
    • /
    • 1999
  • The synthesis of polycrystalline $Al_2TiO_5$ ceramics with low thermal expansion by fusion in an electric arc furnance was investigated. The thermal expansion curves of $Al_2TiO_5$ ceramics were lowered because of microcracks caused by the strong thermal expansion anisotropy of the crystal axes and were accompanied by hysteresis curves. These phenomena are explained by the opening and closing of microcracks. The difference in microcracking temperatures of dilatometric cooling curves in the range of 400~$620^{\circ}C$ is caused by the difference in sintering temperature, grain size and stabilization status.

  • PDF

Nano-CMOS에서 NiSi의 Dopant 의존성 및 열 안정성 개선 (Analysis of Dopant Dependency and Improvement of Thermal stability for Nano CMOS Technology)

  • 배미숙;오순영;지희환;윤장근;황빈봉;박영호;박성형;이희덕
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.667-670
    • /
    • 2003
  • Ni-silicide has low thermal stabiliy. This point is obstacle to apply NiSi to devices. So In this paper, we have studied for obtain thermal stability and analysis of dopant dependency of NiSi. And then we applied Ni-silicide to devices. To improvement of thermal stability, we deposit Ni70/Co10/Ni30/TiN100 to sample. Co midlayer is enhanced thermal stability of NiSi. Co/Ni/TiN, this structure show very difference between n-poly and p-poly in sheet resistance. But Ni/Co/Ni/TiN, structure show less difference. Also junction leakage is good.

  • PDF

$80Al_2O_3-20Al$ 복합재료의 내열충격성: 실험과 유한요소 해석 (Thermal Shock Resistance of $80Al_2O_3-20Al$ Composites: Experiments and Finite Element Analysis)

  • 김일수;신병철
    • 한국세라믹학회지
    • /
    • 제37권3호
    • /
    • pp.201-204
    • /
    • 2000
  • Thermal shock resistance of 80Al2O3-20Al composite and monolithic alumina ceramics was compared. Fracture strength was measured by using a 4-pont bending test after quenching. Thermal stresses of the ceramics and ceramic-metal composites were calculated using a finite element analysis. The bending strength of the Al2O3 ceramics decreased catastropically after quenching from 20$0^{\circ}C$ to $0^{\circ}C$. The bending strength of the composite also decreased after quenching from 200~2$25^{\circ}C$, but the strength reduction was much smaller than for Al2O3. The maximum thermal stress occured in the monolithic alumina ceramics when exposed to a temperature difference of 20$0^{\circ}C$ was 0.758 GPa. The same amount of stress occured in the Al2O3-Al composite when the temperature difference of 205$^{\circ}C$ used.

  • PDF

Thermal buckling resistance of simply supported FGM plates with parabolic-concave thickness variation

  • Benlahcen, Fouad;Belakhdar, Khalil;Sellami, Mohammed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.591-602
    • /
    • 2018
  • This research presents an investigation on the thermal buckling resistance of FGM plates having parabolic-concave thickness variation exposed to uniform and gradient temperature change. An analytical formulation is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. A specific function of thickness variation is introduced where it controls the parabolic variation intensity of the thickness without changing the original material volume. The results indicated that the loss ratio in buckling resistance is the same for any gradient temperature profile. Influencing geometrical and material parameters on the loss ratio in the thermal resistance buckling are investigated which may help in design guidelines of such complex structures.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Code development on steady-state thermal-hydraulic for small modular natural circulation lead-based fast reactor

  • Zhao, Pengcheng;Liu, Zijing;Yu, Tao;Xie, Jinsen;Chen, Zhenping;Shen, Chong
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2789-2802
    • /
    • 2020
  • Small Modular Reactors (SMRs) are attracting wide attention due to their outstanding performance, extensive studies have been carried out for lead-based fast reactors (LFRs) that cooled with Lead or Lead-bismuth (LBE), and small modular natural circulation LFR is one of the promising candidates for SMRs and LFRs development. One of the challenges for the design small modular natural circulation LFR is to master the natural circulation thermal-hydraulic performance in the reactor primary circuit, while the natural circulation characteristics is a coupled thermal-hydraulic problem of the core thermal power, the primary loop layout and the operating state of secondary cooling system etc. Thus, accurate predicting the natural circulation LFRs thermal-hydraulic features are highly required for conducting reactor operating condition evaluate and Thermal hydraulic design optimization. In this study, a thermal-hydraulic analysis code is developed for small modular natural circulation LFRs, which is based on several mathematical models for natural circulation originally. A small modular natural circulation LBE cooled fast reactor named URANUS developed by Korea is chosen to assess the code's capability. Comparisons are performed to demonstrate the accuracy of the code by the calculation results of MARS, and the key thermal-hydraulic parameters agree fairly well with the MARS ones. As a typical application case, steady-state analyses were conducted to have an assessment of thermal-hydraulic behavior under nominal condition, and several parameters affecting natural circulation were evaluated. What's more, two characteristics parameters that used to analyze natural circulation LFRs natural circulation capacity were established. The analyses show that the core thermal power, thermal center difference and flow resistance is the main factors affecting the reactor natural circulation. Improving the core thermal power, increasing the thermal center difference and decreasing the flow resistance can significantly increase the reactor mass flow rate. Characteristics parameters can be used to quickly evaluate the natural circulation capacity of natural circulation LFR under normal operating conditions.