• 제목/요약/키워드: Thermal difference

검색결과 2,302건 처리시간 0.03초

커튼월 유리의 열파손에 관한 실험적 연구 (An Experimental Study on Thermal Breakage in Curtain Wall Glazing)

  • 이재현;남중우;방중석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.236-237
    • /
    • 2013
  • In recent years, the use of glass applied to curtain wall as a building facade material has increased in our nation. However, the non-tempered curved double glass is very easy to broke because it is difficult to guarantee the quality in process of making it into double glazing. So, it is more vulnerable to thermal breakage than tempered double glass. In this paper, surface temperature difference on curved double glazing was compared to that of heat strengthened glass and flat glass by conducting thermal breakage experiments. As a result, flat single glass was broken at temperature difference of 100~140 degrees but curved double glazing was broken at that of 40~60 degrees. Therefore, it was concluded that curved double glazing is more vulnerable than flat double glazing to thermal breakage, and it should be considered the possibility of thermal breakage when curtain wall glazing is applied as a building facade material.

  • PDF

저온 잠열 축열조내의 열유동 특성에 관한 연구 (A study on Characteristics of Heat Flow of Low Temperature Latent Thermal Storage System)

  • 이원섭;박정원
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.33-43
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual all-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. With the relation of the aspect ratio(H/D) in the storage tank, the stratification is formed better as inlet flow rate is smaller. If the inlet and the outlet port are settled at the upside and downside of the storage tank, higher storage rate could be obtainable. In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maitained thin and the degree of stratification increases respectively. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient in case of inlet temperature, the large temperature difference between inflowing water and storage water are influenced from the thermal conduction. The effect of the reference temperature difference is seen differently in comparison with the former study for chilled and hot water. In the discharging process, the thermal stratification is improved by the effect of the thermal stratification of the charging process.

  • PDF

구리와 은 박막의 열팽창계수에 미치는 결정립 크기와 박막 두께의 영향 (The Effect of Grain Size and Film Thickness on the Thermal Expansion Coefficient of Copper and Silver Thin Films)

  • 황슬기;김영만
    • 대한금속재료학회지
    • /
    • 제48권12호
    • /
    • pp.1064-1069
    • /
    • 2010
  • Thin films have been used in a large variety of technological applications such as solar cells, optical memories, photolithographic masks, protective coatings, and electronic contacts. If thin films experience frequent temperature changes, thermal stresses are generated due to the difference in the coefficient of thermal expansion between the film and substrate. Thermal stresses may lead to damage or deformation in thin film used in electronic devices and micro-machined structures. Thus, knowledge of the thermomechanical properties of thin films, such as the coefficient of thermal expansion, is an important issue in determining the stability and reliability of the thin film devices. In this study, thermal cycling of Cu and Ag thin films with various microstructures was employed to assess the coefficient of thermal expansion of the films. The result revealed that the coefficient of thermal expansion (CTE) of the Cu and Ag thin films increased with an increasing grain size. However, the effect of film thickness on the CTE did not show a remarkable difference.

기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가 (Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea)

  • 이승철
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

정현적인 온도 분포를 갖는 두 수평 평판 사이에서의 작은 Rayleigh 수 열 대류 (Low Rayleigh Number Thermal Convection Between Two Horizontal Plates with Sinusoidal Temperature Distributions)

  • 유주식;김용진
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.145-152
    • /
    • 2001
  • Low Rayleigh number thermal convection in a fluid layer confined between two-infinite horizontal walls kept at spatially sinusoidal temperature distributions, T_L=T_m+\Delta T\sin \kappax,\;T_U=T_m+\Delta T\sin(\kappax-\beta)$, is theoretically investigated by a regular perturbation expansion method. For small wave numbers, an upright cell is formed between the two walls at $\beta$=0. The cell is tilted, as the phase difference increases, and a flow with tow counter-rotating eddies occurs at $\beta=\pi$. when the wave number is large, isolated eddies are formed near the lower and upper walls, for all the phase differences. There exists a wave number at which maximum heat transfer rate at the walls occurs, at each of the phase differences. And the wave number increases with increase of the phase difference. for a fixed wave number, the heat transfer rate decrease with increase of the phase difference.

  • PDF

그라우트 재료별 열응답 특성 및 열교환기 운전온도 변화 (Thermal Response Property of Grout Materials from In-situ Test and Temperature Variation of Ground Heat Exchanger)

  • 김갑득;이성주;윤여상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.769-775
    • /
    • 2008
  • The objective of this report is to determine the difference of thermal response that grouted two different materials, and compare the simulation result of the length of total ground heat exchanger length that using the ground thermal conductivity. And also to know heat exchange variation of ground heat exchanger temperature that measured with various test depth. The result shows that the test hole grouted with water permeable material got better thermal response than grouted with water impermeable material. However, with consideration of ingnore for the initial 12 hour data, the test hole grouted with impermeable material has larger thermal conductivity than the other. By former thermal conductivity, simulated data by engineering program shows only 3.4% difference or less. This result shows that ground thermal conductivity is not the main variables for the design program of ground heat exchanger. At the cooling or heating mode, base on the depth of -150m, the ground heat exchanger has best temperature at $-90{\sim}-60m$ and than getting worse because of entering water heat exchanged with leaving water in the same hole.

  • PDF

Orofacial Thermal Quantitative Sensory Testing (QST): A Study of Healthy Korean Women and Sex Difference

  • Ahn, Sung-Woo;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • 제40권3호
    • /
    • pp.96-101
    • /
    • 2015
  • Purpose: Thermal sensory test as an essential part of quantitative sensory testing (QST) has been recognized as a useful tool in the evaluation of the trigeminal nerve function. Normative data in the orofacial region have been reported but the data on differences in the test site, sex and ethnicity are still insufficient. Thus, this study aimed to investigate the normal range of orofacial thermal QST data in the healthy Korean women, and assess sex difference of thermal perception in the orofacial regions. Methods: Thermal QST was conducted on 20 healthy women participants (mean age, 26.4 years; range, 21 to 34 years). The thermal thresholds (cold detection threshold, CDT; warm detection threshold, WDT; cold pain threshold, CPT; and heat pain threshold, HPT) were measured bilaterally at the 5 trigeminal sites (the forehead, cheek, mentum, lower lip and tongue tip). The normative thermal thresholds of women in the orofacial region were evaluated using one-way ANOVA and compared with the previously reported data from age- and site-matched 30 healthy men (mean age, 26.1 years; range, 23 to 32 years) using two-way ANOVA. One experienced operator performed the tests of both sexes and all tests were done in the same condition except the time variability. Results: Women showed significant site differences for the CDT (p<0.001), WDT (p<0.001), and HPT (p=0.047) in the orofacial region. The CDT (p<0.001) and the CPT (p=0.007) presented significant sex difference unlike the WDT and the HPT. Conclusions: The thermal sensory evaluation in the orofacial region should be considered in the context of site and sex and the normative data in this study could be useful for assessment of the sensory abnormalities in the clinical setting.

적외선 체열진단을 이용한 구안와사 환자(Bell's palsy)의 호전기간에 대한 임상연구 (Clinical study on the improving period of the bell's palsy patients with D.I.T,I)

  • 박용호;유미경;박윤희;박수연;최정화;김종한;김대수
    • 한방안이비인후피부과학회지
    • /
    • 제19권2호
    • /
    • pp.202-211
    • /
    • 2006
  • Objectives : This study is designed to evaluate correlation between the data of D.I.T,I examination in Bell's palsy and the improving period. Methods : This study researched into the clinical statistics for 50 patients who are in Bell's palsy and they are treated with oriental medical care of Dongshin university during 18months from January 1, 2005 to June 1, 2006. The data which examinated by D.I.T.I, are the thermal difference of normal and abnormal site of acupuncture int Gl4 BL2 GB3 S3 S4 S6 TE17 in Bell's palsy. Result : There was statistic significance between thermal difference of normal, abnormal site and the improving period. The period was shorter in normal thermal pattern than hypothermal pattern, hyperthermal pattern. Conclusion : According to the result, there was a statistic significance that more thermal difference and more difficult to recover in Bell's palsy.

  • PDF

원전 안전주입 배관에서의 In-Leakage 에 의한 열성층 현상에 관한 연구 (A Study on Thermal Stratification Phenomenon due to In-Leakage in the Safety Injection Piping of Nuclear Power Plant)

  • 김광추;박만홍;염학기;김태룡;이선기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1633-1638
    • /
    • 2003
  • In case that in-leakage through the valve disk occurs, a numerical study is performed to estimate on thermal stratification phenomenon in the Safety Injection piping connected with the Reactor Coolant System piping of Nuclear Power Plant. As the leakage flow rate increases, the temperature difference between top and bottom of horizontal piping has the inflection point. In the connection point of valve and piping, the maximum temperature difference between top and bottom was 185K and occurred in the condition of 10 times of standard leakage flow rate. In the connection point of elbow and horizontal piping, the maximum temperature difference was 145K and occurred in the condition of 15 times of standard leakage flow rate. In the vertical piping of Safety Injection piping, the near of connection point between elbow and vertical piping showed the outstanding thermal stratification phenomenon in comparison with another region because of turbulent penetration from Reactor Coolant System piping. In order to prevent damage of piping due to the thermal stratification when in-leakage through the valve disk occurs, the connection points between valve and piping, and the connection points between elbow and piping need to be inspected continually.

  • PDF

충남지역 농촌 주거용 건물의 열쾌적성능에 관한 연구 (The Study on the Thermal Comfort of Rural Housing in Chung-nam area)

  • 박재상;윤종호;박재완;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.202-207
    • /
    • 2011
  • This study has measured indoor temperature and relative humidity and evaluated it for one year by selecting Chungnam's rural areas for improving indoor environment of rural housing in the circumstance that the environment of housing is poor due to deterioration of rural housing. As a result of its evaluation, the indoor temperature difference by household appeared to be more than $13^{\circ}C$, and it was measured that the indoor temperature was mostly low. A difference of more than 40% in case of relative humidity occurred, so the difference of the indoor environment by household was clear. In case of the thermal comfort zone, the number of households that are distributed to more than 50% of a thermal comfort criterion in the winter was only 3 households, rather than the summer.

  • PDF