• Title/Summary/Keyword: Thermal deviation

Search Result 224, Processing Time 0.025 seconds

The Influence of Therapeutic Horseback Riding on Treatment of Low Back Pain (요통치료에서 승마요법의 영향)

  • Jang, Sang Chul;Lee, Ki Seung;Kim, In Chang;Kim, Jin Hee;Chong, Myong Soo
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2015
  • This study is aimed to verify what effects horseback riding has in treating hospitalized patients with low back pain in the Korean medicine hospital. The method of this study is choosing 31 people among hospitalized male and female patients whose chief complaints were low back pain in 2 Korean medicine hospital in Gyeonggi Province. 14 people who agreed to take horseback riding treatment were classified into experimental group and 17, the rest of the people, were classified into control group. Both experimental group and control group were treated with Korean medicine. In addition, only experimental group performed horseback riding program. Changes of temperature difference by digital infrared thermal imaging(DITI), sit and reach test and visual analogue scale(VAS) survey were used as measuring tools. IBM SPSS Statistics 21 was used in processing statistics. Mean ${\pm}$standard deviation was indicated down to two places of decimals and the level of significance was judged as p<0.05. The summary of this study's result is as in the following. First of all, the meaningful difference was shown in the experimental group but not in the control group in the difference of temperature between Yintang and Kwanwon(the difference between up and down). Secondly, there were significant difference in the experimental group which performed horseback riding treatments but not in the control group resulting from examining the change of temperature difference between left and right Yongchon. Thirdly, there were significant difference between experimental and control group in the change of sit and reach. Especially, the change was much more in experimental group. As known from the results above, patients who only were treated with Korean medicine relieved low back pain, reordered pelvis and improved the motor ability. However, the group which carried out horseback riding at the same time reordered pelvis and improved the motor ability more obviously.

  • PDF

Analytical and experimental study on the quality improvement of 2 cavity injection-molded LCD frame (2 캐비티 LCD 사출품의 품질향상에 관한 해석 및 실험적 연구)

  • Son, Jae-Hwan;Jang, Eun-Sil;Han, Chang-Woo;Son, Jae-Yong;Lee, Young-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3815-3821
    • /
    • 2012
  • The LCD frame is an important part which supports the BLU of medium/large sized TFT-LCD. To produce it efficiently, it is necessary to achieve the molding process improvement from 1 cavity to 2 cavity system. Because 2 cavity mold is compact and its hot-runner zone is broadened, it is difficult to control the temperature on the mold. In this study, injection molding analysis on the frame in 2 cavity process with FEA(Finite Element Analysis) software is carried out to estimate its quality. The calculated injection molding pressures and maximum deflection in 1 and 2 cavity processes are 41.13 MPa and 1.62 mm, 40.49 MPa and 1.66 mm respectively. The measured maximum flexure load and surface roughness of the left and right frame of 2 cavities are 209 N and 0.08 ${\mu}m$, 193 N and 0.10 ${\mu}m$ while those in 1 cavity are 140 N and 0.13 ${\mu}m$. Thermal image shows that the maximum standard deviation of the temperature on left and right side of 2 cavity mold is $1.23^{\circ}C$. The simulation and measurement results show that the quality of the frame in 2 cavity injection molding process as a whole is not worse than that of 1 cavity system. But maximum flexure loads of the frame in 2 cavity process are far greater than that in 1 cavity process.

Study in the Measurement of Boron Isotopes by Thermal Ionization Mass Spectrometer (열 이온화 질량분석기를 이용한 보론 동위원소 비 측정연구)

  • Jeon, Young Shin;Joe, Kih Soo;Han, Sun Ho;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • $Li_2B_4O_7$ and $Na_2B_4O_7$ were synthesized with boron isotopic standard material for the measurement of boron isotopes of positive ions (PTIMS) such as $Li_2BO_2{^+}$ (mass 56, 57) and $Na_2BO_2{^+}$ (mass 88, 89) instead of boron mass 10 and 11. The negative ions (NTIMS) such as $^{10}BO_2{^-}$ and $^{11}BO_2{^-}$(mass 42와 43) were also measured with the same boron isotopic standard material. The precision and accuracy were compared between each method, and prescan of isobaric effect was studied. Good result was obtained from NTIMS method which provided the stable and enough peak intensities with good precision and accuracy. The measurement of boron isotopes were performed in ground water sample with about 8 ng-B ($5{\mu}L$ sample solution) obtained from IAEA for international inter-comparison analysis. The standard deviation was found to be 0.03%. Boron content of this ground water was measured using the NTIMS-IDMS. The result was $1.65{\pm}0.003ug-B/mL$ which was better precision compared to the ICP-AES result.

The Experimental Study of Various Salts on the Characteristics of Heat Transfer in Indirect Moxibustion with Salt (염(鹽)의 종류(種類)에 따른 격염구(隔鹽灸)의 열전달(熱傳達) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Gun-hyee;Seo, Eun-mi
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.119-135
    • /
    • 2004
  • Objective: The purpose of this study is to investigate the mechanism and effect of moxibustion with salt objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with salt. Methods: We have selected of the moxibustion with salt of indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with salt as a kind of the 4 salt. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results: 1. We make out that it is not significantly change the time of thermal conduction of moxibustion with salt as a kind of 4 salt. 2. The heating period of Refined Salt was long and that of Sun-dried Salt was a short time respectively. The heating period of maximum tamperature is high Sun-dried Salt, Mechanical Salt and Refined Salt orderly. Maximun heating speed in the heating period was $0.151{\sim}0.184^{\circ}C/sec$ and at the same tendency of the maximum temperature in the heating period. 3. The retaining period was shorter than the heating period respectively, that is 15~24% of the combustion time of in the heating period. We make out that it is not significantly different the time of the retaining period as a kind of 4 salt. The mean temperature of retaining period was $43.2{\sim}48.1^{\circ}C$, that was extraordinarily high temperature. 4. We make out that it is not significantly different the time of the cooling period as a kind of 4 salt. The cooling period was measured 223~233sec. Beacuse the same density and size of moxa combustion was made an experiment. 5. The effective combustion time of Refined Salt is longer(259sec) than that of Sun-dried Salt(173sec). It is significantly different the time of the combustion time as a kind of 4 salt. 6. It is significantly different the Sample deviation of the combustion time as a kind of 4 salt because of the water content of the 4 salt individually. Conclusions: As the base on this study, we obtained the conclusion as the follows. The salt of moxibustion with salt was fitted for Sun-dried Salt due to making to Mechanical Salt recently. The Refined Salt is composition rate to another and small size comparatively. So It was fitted for the salt of moxibustion with salt. It is necessary to study continuously about the more suitable moxibustion with salt and quantitative analysis about the moxibustion with salt.

  • PDF

Seasonal variation in growth of Berkshire pigs in alternative production systems

  • Park, Hyeon-Suk;Oh, Sang-Hyon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.5
    • /
    • pp.749-754
    • /
    • 2017
  • Objective: The objective of the present study was to investigate the effects of farrowing month (FM), parity and sex on the growth performance of Berkshire swine raised in alternative production systems. Methods: A total of 40 farrowing records from 27 sows and 1,258 body weight (BW) records from 274 piglets collected over a two-year period were used for the analysis. The BWs were recorded at birth, weaning (28 d), 56, 84, 112, and 140 days. Any BW not recorded on schedule was recalculated to conform the days of age among corresponding BW records, using growth curves drawn with polynomial functions whose power was determined by the number of existing observations for each individual. Results: The mean parity (${\pm}$standard deviation) of the sows was $3.42{\pm}2.14$. The sows that farrowed in June had the lowest number of total born with an average of $6.25{\pm}2.22$ piglets per sow. However, the lowest average number of piglets weaned at day 28 was found in sows that farrowed in May, as well as the highest number recorded for the stillborn piglets with an average of 2.67 piglets per sow. Moreover, the smallest increase in weight from birth to weaning occurred in piglets that were farrowed in May, which also corresponds with the average daily gain (ADG) of 0.29 kg and the last recorded weight measurement on day 140 of $41.69{\pm}1.45kg$. Contrastingly, the highest growth rate was found among pigs farrowed in June, with the largest increase in weight of 7.55 kg from birth to weaning, the highest ADG of 0.51 kg from birth to 140 day of age and the highest BW of $74.70{\pm}1.86kg$ recorded on day 140. Conclusion: Pigs farrowed in June also had the least number of piglets that died between birth and weaning. The zone of thermal comfort found in sows reared in indoor confinement systems did not improve the reproductive performance of the sows reared in an outdoor, alternative production system, while the growth performance of the piglets was improved when the ambient temperature was consistently hot or consistently cold.

A Current State of Multihousing Evaluation Based on the Construction Criteria and Performance Codes of Green Homes (친환경주택의 건설기준 및 성능규정에 의한 공동주택 평가현황에 관한 연구)

  • Lee, Seul-Bi;Yu, Ki-Hyung;Yoon, Seong-Hoon
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.113-118
    • /
    • 2015
  • Purpose: In Korea, buildings make up 20.5% (2012) of the gross national energy consumption, so they are a major target for greenhouse gas reduction. In particular, energy consumption in multihousing represents approximately 32.6% of the entire building sector. With improving energy performance being the focus, efforts are continuously being made to reinforce standards and systems in greenhouse gas reduction. This study investigated the current status of multihousing in Korea in terms of energy performance as described in the performance evaluation reports submitted (to an institution that specializes in reviewing the performance evaluation of green homes) based on the construction criteria and performance codes for green homes and examined if the evaluation criteria using related methodologies were appropriate. The results will provide helpful information for reviewing the future directions of operations and amendments to the systems. Method: The overall characteristics of the system were examined using the evaluation methodologies (and current state of revisions) of the performance codes for green homes and comparing them with similar systems. Also, the current state of application and energy performance (conducted according to the evaluation methodologies) were compared by the evaluation institution for multihousing neighborhoods that were assessed for five years from 2010 to 2014. Result: It has been confirmed that the performance codes for green homes are different from other similar systems in evaluating performances of multihousing in that they allow both quantitative and qualitative methods of evaluation, and they consider both energy and sustainability simultaneously in the evaluation. Furthermore, regarding the adoption rate of the forms for the two evaluation methods (Form 1 - quantitative and Form 2 - qualitative), the rate preferring Form 2 increased gradually in time to reach 55.3% in 2014. In analyzing the rate of overall energy reduction (submitted in Form 1) and the coefficient of thermal transmission for each part (submitted in Form 2), it was observed that the deviation between the performance submitted and the criteria decreased in line with the level of reinforcement.

A Numerical Modeling of the Temperature Dependence on Electrochemical Properties for Solid Oxide Electrolysis Cell(SOEC) (고체 산화물 수전해 시스템(SOEC)에서 전기화학적 특성의 온도 의존성에 대한 수치 모델링)

  • Han, Kyoung Ho;Jung, Jung Yul;Yoon, Do Young
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.1-9
    • /
    • 2020
  • In recent days, fuel cell has received attention from the world as an alternative power source to hydrocarbon used in automobile engines. With the industrial advances of fuel cell, There have been a lot of researches actively conducted to find a way of generating hydrogen. Among many hydrogen production methods, Solid Oxide Electrolysis Cell(SOEC) is not only a basic way but also environment-friendly method to produce hydrogen gas. Solid Oxide Electrolysis Cell has lower electrical energy demands and high thermal efficiency since it is possible to operate under high temperature and high pressure conditions. For these reasons, experimental researches as well as studies on numerical modeling for Solid Oxide Electrolysis Cell have been under way. However, studies on numerical modeling are relatively less enough than experimental accomplishments and have limited performance prediction, which mostly is considered as a result from inadequate effects of electrochemical properties by temperature and pressure. In this study, various experimental studies of commercial Membrane Electrode Assembly (MEA) composed of Ni-YSZ (40wt%, Ni-60 wt% YSZ)/8-YSZ (TOSOH, TZ8Y)/LSM (La0.9Sr0.1MnO3) was utilized for improving effectiveness of SOEC model. After numerically analyzing effects of electrochemical properties according to operating temperature, causing the largest deviation between experiments and simulation are that Charge Transfer Coefficient (CTC), exchange current density, diffusion coefficient, electrical conductivity in SOEC. Analyzing temperature effect on parameter used in overpotential model is conducted for modeling of SOEC. cross-validation method is adopted for application of various MEA and evaluating feasibility of model. As a result, the study confirm that the numerical model of SOEC based on structured process of effectiveness evaluation makes performance prediction better.

Improvement of Air Temperature Analysis by Precise Spatial Data on a Local-scale - A Case Study of Eunpyeong New Town in Seoul - (상세 공간정보를 활용한 국지기온 분석 개선 - 서울 은평구 뉴타운을 사례로 -)

  • Yi, Chae-Yeon;An, Seung-Man;Kim, Kyu-Rang;Choi, Young-Jean;Scherer, Dieter
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.1
    • /
    • pp.144-158
    • /
    • 2012
  • A higher spatial resolution is preferable to support the accuracy of detailed climate analysis in urban areas. Airborne LiDAR (Light Detection And Ranging) and satellite (KOMPSAT-2, Korea Multi-Purpose Satellite-2) images at 1 to 4 m resolution were utilized to produce digital elevation and building surface models as well as land cover maps at very high(5m) resolution. The Climate Analysis Seoul(CAS) was used to calculate the fractional coverage of land cover classes in built-up areas and thermal capacity of the buildings from their areal volumes. It then produced analyzed maps of local-scale temperature based on the old and new input data. For the verification of the accuracy improvement by the precise input data, the analyzed maps were compared to the surface temperature derived from the ASTER satellite image and to the ground observation at our detailed study region. After the enhancement, the ASTER temperature was highly correlated with the analyzed temperature at building (BS) areas (R=0.76) whereas there observed no correlation with the old input data. The difference of the air temperature deviation was reduced from 1.27 to 0.70K by the enhancement. The enhanced precision of the input data yielded reasonable and more accurate local-scale temperature analysis based on realistic surface models in built-up areas. The improved analysis tools can help urban planners evaluating their design scenarios to be prepared for the urban climate.

Manufacturing and Structural Analysis of Thick Composite Spar Using AFP Machine (AFP로 제작된 두꺼운 복합재료 스파의 제작 및 구조 해석)

  • Kim, Ji-Hyeon;Han, Jun-Su;Bae, Byung-Hwan;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.212-218
    • /
    • 2015
  • A large composite spar was manufactured using an automatic fiber placement (AFP) machine. To verify its structural performance, the weakest part of the structure, which is called 'corner radius', was tested under bending and examined by finite element analysis. Since the application of AFP machine to composite structure fabrication is still in early stage in Korea, this paper presents the summary of whole process for manufacturing composite spar using AFP machine from mandrel design and analysis to verification test. The deflection and stress by mandrel weight and AFP machine force, thermal deformation and natural frequency were all examined for mandrel design. The target structure was composite C-spar and cured in an autoclave. Test results were compared with nonlinear finite element analysis results to show that the structure has the strength close to the theoretical value. It was confirmed that the corner radius of the spar manufactured by AFP process showed deviation less than 20% compared with first ply failure strength. The results indicate that the AFP technology could be used for large scale composite structure production in the near future.

Burning Characteristics of Nitramine Propellant Embedded with Metal Wires (금속선을 삽입한 니트라민계 추진제의 연소특성)

  • 유지창
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.50-58
    • /
    • 2000
  • Burning rate of the matrix propellant($r_{sb}$) and burning rate along the metal wire($r_w$) were measured and analyzed for the HTPB/AP/Al propellant embedded with Ag wire($\phi$0.15mm) according to weight % of RDX(0~20%). Variation of burning rate increment ratio($r_w$/$r_{sb}$) and pressure exponent(n) was studied for the nitramine propellant having 10% RDX embedded with three kinds of metal(Ag, Cu, and Ni-Cr) of which diameter range is between 0.1~0.6mm. Maximum burning rate increment ratio of the nitramine propellant embedded with Ag wire($\phi$0.1mm) was 5.94 at $20^{\cire}C$, 1000 psia, 16.4% faster than that of HTPB/AP propellant, it is because that autoignition temperature of the nitramine propellant was higher than that of HTPB/AP propellant. Standard deviation of absolute ($r_{wc}$/$r_{we}$)/$r_{we}$ calculated by using new empiracal equation composed of four dimensionless groups, is 6.11% less than that calculated by using original empirical equation composed of three dimensionless group. The new empiracal equation is derived from Buckingham pi theorem using the parameters such as thermal diffusivity, melting temperature. wire diameter, propellant sample diameter, frame temperature, autoignition temperature and matrix burning rate which influence on $r_w$.

  • PDF