• Title/Summary/Keyword: Thermal connection

Search Result 186, Processing Time 0.034 seconds

The Fabrication Processes for the Planarization of Sacrificial Layers over Hollow Structures (Hollow Structure에서의 희생층 평탄화 제작 공정)

  • Yoon Yong-Seop;Bae Ki-Deok;Choi Hyung;Jun Chan-Bong;Ro Kwang-Choon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.546-550
    • /
    • 2004
  • Two fabrication approaches are proposed to planarize the sacrificial layer over hollow structures. One is the photoresist filling method that makes use of photolithography, thermal curing and plasma ashing. The other is the lamination method that is applying pressure and temperature to the organic film over the hollow structures. The fabrication results are compared with those of CMP process. Trenches and cavities with various dimensions have been made for the porposed process. Upon measuring the planarization levels, they are dependent on planarization methods and the geometrical size of hollow structures. The photoresist filling method is so strongly dependent on the width and depth of trenches that we have problems to use it for large dimensional trenches. To the contrary, the flatness of sacrificial layer over the trenches was found to be almost independent of trench dimensions for the lamination method. A CMP process shows the most excellent results, but the fabrication is complicated and the access to it is not so easy. It is important to choose the proper planarization method by considering the required flatness levels, materials to be planarized, and connection between the planarization step and the previous or the following process of it.

A study on thermal and mechanical properties according to the structures of conductor sleeve and the method of connection for EHV Cables (전력 케이블용 접속 슬리브의 구조 및 접속 방법에 따른 특성 연구)

  • Kim, Young-Bum;Han, Bong-Soo;Ryu, Jeong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1493_1494
    • /
    • 2009
  • 초고압 전력 케이블용 도체 접속을 위한 접속방법으로 압축형(compressing type), 용접형(welding type), 압축-용접형(CW type; compressing-welding type)의 슬리브는 물론 동과 알루미늄의 이종(nonidentical materials) 접속을 위한 슬리브를 개발 하였으며, 전기적, 기계적으로 검증된 제품 개발을 위하여, 슬리브의 구조 변경과 접속 방법의 차이뿐 아니라 접속 전후의 응력 평가를 위해 슬리브 시편의 인장시험(tensile strength) 결과에 따른 슬리브 제작 및 시험을 진행하였다. 신뢰성 있는 제품 개발과 데이터를 얻기 위하여 초고압용 지중 고압 케이블을 시험 시료로 적용하여 시험 선로(test loop)를 구성하였으며, 이를 통하여 구조와 재질에 따른 접속 방법, 이상 온도 상승 또는 국부적인 고온 부위 발생 여부 등의 전기 시험 및 열싸이클 전압 시험(heating cycle voltage test) 조건을 설정하여 시험 전후의 열신축 등 전기적, 기계적 특성을 평가하였다. 접속 슬리브의 구조 및 재질에 따른 위치별 발열 양상을 체크하였으며, X-ray 장비를 이용하여 슬리브 내부의 압축 및 충진 정도를 점검함으로써 기존 접속 슬리브 보완은 물론 개발된 접속 슬리브의 설계 기준 및 안전율을 설정 할 수 있었다.

  • PDF

Analysis of Thermal Characteristics by Poor Contacts at the Connection Parts of DC Power Appliances (DC 전원설비 접속부에서의 접촉불량에 의한 발열특성 분석)

  • Kim, Hyang-Kon;Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2158_2159
    • /
    • 2009
  • 본 논문에서는 DC전원설비 접속부에서의 접촉불량에 의한 발열 특성에 대하여 실험, 분석하였으며 사용된 DC 전원설비는 상용 교류전원을 직류전원으로 변환하는 AC/DC 컨버터의 출력전원을 이용하는 LED 가로등 조명설비의 전원 접속부을 대상으로 하였다. 외부의 기계적 진동에 의해 동전선 접속부에 아크와 열이 발생하며 이때 발생한 발열 온도와 열 분포를 측정하였으며 적열부가 형성된 후 25분이 경과하였을 때 최고 $842.68^{\circ}C$까지 온도가 상승하였으며 접속부의 접촉전압은 1.5~1.6V, 통전전류는 6.6~6.9A로 약간의 변화만 나타남을 볼 수 있었다. 또한 DC전원에서 동전선 접속부에서의 산화물 생성과 증식 거동에 대하여 분석하였으며 AC전원에서와 유사하게 산화물이 형성되어 성장함을 볼 수 있었다. 이러한 실험과 분석 결과는 향후, DC 전원설비에서의 전기화재 예방을 위한 자료로 활용 가능할 것으로 기대된다.

  • PDF

A Study on the Characteristics of Ecological Design in Modern Architecture space (근대건축공간의 생태적 디자인 특성에 관한 연구)

  • Rhee Youn-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.52-61
    • /
    • 2005
  • Ecological traces appearing in contemporary architecture are based on modern architecture and most aspects on the contemporary architecture are related with the successive trend or break of the modern architecture. The concept of environment in the modern age has established clear destination, as it has been considered as nature. The architecture under a mechanical world view in the modem age has sustained the opposing connection with nature as environment. However, there have been architects maintaining the sympathy with nature in that vortex. This trend has been regarded as same context as ecological architecture and estimated to the outpost of ecological characteristics appearing in the contemporary architecture. This study is to make it clear that the ecological manifestation in the contemporary architecture is based on the ecology in the modem architecture through considering ecological ideals of architects in the modern architecture and considering space composition and structural properties in the modern architecture of ecological paradigm. The scope of this study contains spacial analysis, design strategy, and design types of organic architecture in nature, which has appeared from the modern age. First, the division into period is carried out according to the organic tendency of non-mainstream in the modern architecture: Arts and Crafts Movement, Art Nouveau, Sezession, Expressionism, Organic Architecture, Regionalism, Internationalism. Therefore, this study is significant to be on the search for a start to suggest ecological point of view to architectural space in modern architecture and is search organic characteristics for ecological characteristics in modern architecture; organic relation, thermal buffer space, regionalism, multi-layer, energy efficiency.

Compatibility of Continuous Rabi Oscillation and Discontinuous Quantum Jumps (연속적 라비 진동과 불연속적 양자도약의 양립성)

  • Chough, Young-Tak;Kim, Kisik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.2
    • /
    • pp.77-86
    • /
    • 2012
  • The connection between the continuousness of Rabi oscillation and the discontinuity of quantum jumps has long remained one of the conceptual difficulties since the discovery of the quantum physical paradigm. In this study, however, we demonstrate that the behavior of the atom-field composite system gradually changes from the continuous Rabi interaction to the discontinuous quantum jumps as the atom-field coupling strength is reduced. The reduction occurs through enlarging the quantization volume of the mode so that the mode approaches one of the infinitely many modes of the thermal background.

Performance Experiment of H-120 Class Fire Damper for Offshore (해양플랜트용 H-120 Class 파이어 댐퍼의 성능 실험)

  • Jang, Sung Cheol;Hur, Nam-Soo;Kim, In-Whan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.131-136
    • /
    • 2014
  • In this paper, a fire resistance test was carried out in accordance with the change of the insulation conditions on the exposed side and unexposed side of a coaming to obtain the optimal insulation conditions for class H-120 insulation in connection with specimen1 of the preceding paper for an evaluation of the fireproof performance of fire dampers according to hydrocarbon fire conditions. In the test results, specimen2(88 mm, $171^{\circ}C$) met the class H-120 insulation conditions, but specimen3(76mm, $181^{\circ}C$) exceeded the thermal insulation acceptance criteria at 110 minutes. Therefore, specimen2(88 mm) represents the optimal insulation conditions as a possible lightweight materialas compared to specimen1. From a comparison of the test results, we concluded that the temperature increase of the coaming insulation surface was influenced by conductive heat from the bulkhead and that the coaming surface was influenced by radiant heat from the blade and coaming.

Investigation of I-V characteristics and heat generation of multiply connected HTS conductors in parallel

  • Park, H.C.;Kim, S.;Cho, J.;Sohn, M.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.2
    • /
    • pp.20-23
    • /
    • 2012
  • With continuous development of the 2nd generation HTS conductor, the critical current of the conductor is also increasing. However, many applications require more than 2 conductors in parallel to transport large current. Applications such as HTS power cables and some HTS current leads usually need much larger transport current than that provided by a single conductor and they require more than several tens of HTS conductors. In the case of parallel connection of multiple HTS conductors, the current distribution depends on the contact resistance of each conductor at the terminals for DC operation. The non-uniform distribution of the terminal resistances results in a non-uniform distribution of the current. The resultant current non-uniformity affects on the measurement of the I-V curve and the thermal performance of the multiple conductors. This paper describes the I-V curves obtained from multiply connected HTS conductors with different terminal contact resistances to investigate the relationship between the distorted I-V curve and heat generation.

Behavior of UHPC-RW-RC wall panel under various temperature and humidity conditions

  • Wu, Xiangguo;Yu, Shiyuan;Tao, Xiaokun;Chen, Baochun;Liu, Hui;Yang, Ming;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • v.9 no.5
    • /
    • pp.459-467
    • /
    • 2020
  • Mechanical and thermal properties of composite sandwich wall panels are affected by changes in their external environment. Humidity and temperature changes induce stress on wall panels and their core connectors. Under the action of ambient temperature, temperature on the outer layer of the wall panel changes greatly, while that on the inner layer only changes slightly. As a result, stress concentration exists at the intersection of the connector and the wall blade. In this paper, temperature field and stress field distribution of UHPC-RW-RC (Ultra-High Performance Concrete - Rock Wool - Reinforced Concrete) wall panel under high temperature-sprinkling and heating-freezing conditions were investigated by using the general finite element software ABAQUS. Additionally, design of the connection between the wall panel and the main structure is proposed. Findings may serve as a scientific reference for design of high performance composite sandwich wall panels.

Study on Assembly of TF Coil Structure in KSTAR Tokamak (KSTAR 토카막 장치에서 TF 자석 구조물의 조립에 관한 검토)

  • Kim, K.M.;Choi, C.H.;Hong, K.H.;Yang, H.L.;Yu, I.K.;Her, N.I.;Sa, J.W.;Kim, H.K.;Kim, G.H.;Kim, S.T.;Kim, H.T.;Yang, J.S.;Bak, J.S.;Kim, C.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1262-1267
    • /
    • 2003
  • TF magnet structures are the main structural components in the KSTAR magnet systems to protect the superconducting coils from mechanical, electrical, and thermal loads. TF coil structure supports CS and PF coil system. The inter-coil structure contains adjustable shear keys and conical bolts to provide pre-loading in toroidal direction and to resist against in-plane and out-of-plane forces that are the most critical loads on the TF magnet system. The conical bolts and shear keys are specially designed to assemble easily and to provide a convenient accommodation for a good alignment. The connection plate that is one of the prototype fabrications had been manufactured to study adjustability of conical bolts and shear keys for assembly of TF coil structure. We could measure the misalignments at the keyways and conical holes with the misalignment measuring instrument.

  • PDF

Superconducting Transitions of $(Pb,V)Sr_2(Ca,Er)Cu_2O_z$ Quenched from High Temperatures

  • Lee, Ho-Keun
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.9-13
    • /
    • 1999
  • The influence of quenching temperature and annealing time on superconducting characteristics has been investigated for a $(Pb_{0.6}V_{0.4})Sr_2(Ca_{0.65}Er_{0.35})Cu_2O_z$ compound. From the resistivity measurements for samples annealed at $400^{\circ}C$ to $860^{\circ}C$ in oxygen and subsequently quenched, it is observed that $T_c$(zero) of the sample decreases with the increase of annealing temperature up to $600^{\circ}C$ and increases again beyond $700^{\circ}C$. Annealings of the sample at $860^{\circ}C$ show that $T_c$(zero) goes through a maximum of 62K with the increase of the annealing time. It is also found that $T_c$(zero) of the sample quenched from high temperature decreases when the sample is subjected to low temperature annealing below. $600^{\circ}C$ in oxygen. The experimental results indicate that the as-prepared samples contain excessive oxygen and removal of this excessive oxygen in as-prepared samples is a key factor in controlling the superconducting properties of the samples and are discussed in connection with thermal gravimetric measurements.

  • PDF