• Title/Summary/Keyword: Thermal conditions

Search Result 4,621, Processing Time 0.032 seconds

A Seasonal Indoor Thermal Conditions of a Newly-launched Training Ship

  • Hwang, Kwang-Il;Shin, Dong-Keol;Lee, Jin-Uk;Lee, Sang-Il
    • Journal of Navigation and Port Research
    • /
    • v.33 no.4
    • /
    • pp.289-294
    • /
    • 2009
  • The living performances of crews and passengers in cabins have been less received attention, while Korea is a top leading country in ship building industry. To develop a high value added ships like 5-star cruisers, researches on the comfort and productivity in cabins should be carried out with urgent. The purpose of this study is to measure and analyze of the ship's indoor thermal conditions in spring, summer and winter, and also to compare the seasonal differences, of which conditions are supplied from and controlled by marine HVAC The temperature, humidity and air supply volume of 5 different needs of cabins on a training ship were measured through a year, which was launched at Dec. 2005 and totally 246 crews can go on board for education. The following results were obtained: (1)In the spring, the temperature in cabins was measured as $20{\sim}25^{\circ}C$ and humidity was below 30%. (2)In the summer, the temperatures was controlled at $21{\sim}27^{\circ}C$ in almost cabins and humidity was between $40{\sim}60%$ which is known as comfort conditions. (3)In the winter, temperature and humidity was maintained between $19{\sim}26^{\circ}C$, and humidity was between $10{\sim}50%$. (4)It is clear that the humidity conditions in cabins are not properly controlled at all through a year to satisfy the Comfort Standards provided by ASHRAE and/or ISO, In conclusion, humidification and dehumidification of cabins must be treated with importance for more comfort living and working environments for crews and passengers.

A Basic Study on the Analysis Method of Thermography (Thermography의 분석방법에 관한 기초연구)

  • Lee, Hyuk-Jae;Park, Young-Jae;Oh, Hwan-Sup;Lee, Sang-Chul;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.110-122
    • /
    • 2005
  • Background: The basic concept of thermographic interpretation is the thermologic equality of both side in normal person. But both sides diseases were limited diagnostic values by thermographic interpretation, and this interpretation does not apply to the case in thermal temperature of each part of body. Nevertheless, the measurement conditions are not standardized. So, for its clinical applications are extended, we think that the measurement conditions are considered the individual variations. Objectives: The purpose of this study is to examine the optimum conditions thermal temperature of the time period and region are not effected by internal and external variables. Methods: After the subjects took off their clothes, the filming were repeatedly five times made on duration of 5minutes during 20minutes. We selected nine regions around acupoints including Yin dang[印堂, HN1], Sugu[水溝, GV26], Ch’ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Ch’onch'u[天樞 S25], No-gung[勞宮, P8], and calculated based on the utility of R.O.I.(Region of Integer) in our system these points temperature. We measured the optimal time period and region that has little variation of thermal temperature. Results: The results shows that the optimal time period is 20minutes after undressed, and the optimal region is the region around acupoints including Sugu[水溝, GV26]. Conclusions: we obtained the measurement conditions were considered the individual variations. And also, this study offers basic sources for that the measurement conditions would be standardized. Furthermore, based on this results, we expect that clinical applications using thermography would be extended.

  • PDF

A Study on the Development of Cooling Simulation Program for Thermal Environmental Chamber (열환경챔버의 냉방 시뮬레이션 프로그램 개발에 관한 연구)

  • 이한홍
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.5
    • /
    • pp.108-114
    • /
    • 1999
  • The thermal environmental chamber has been using in maintaining weather condition keeping thermal capacity under heating and cooling load fluctuation and for the performance testing of cooling system or air-conditioner on artificial envi-ronment. In ordder to make the various environmental conditions in the thermal environmental chamber the proper cooling system is necessary to eliminate the heating load produced inside the chamber and to maintain the designed environmental condition. For this reason the optimal design of cooling system and the prediction of performance is also required. This paper describes the prediction of performance of cooling system in the thermal environmental chamber with the capacity of 37,000kcal/hr which is developed for the test of performance in heating mode of heat pump system, In the results this paper is trying to develop simulation program on the base of mathematical models and which can be applied effectively to the optimal design of cooling system and prediction of performance to the inside and outside change of envi-ronmetal load.

  • PDF

Application of Thermal Discharge Dispersion Model on Cheonsu Bay (천수만 해역에서 온배수 확산모델의 적용)

  • 박영기
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.169-180
    • /
    • 1995
  • This Daper presents effective simulation of the dispersion of thermal discharge which can be relesed at Boryong power plant. Applied numerical models are finite difference method for hydrodynamic analysis and Masch-model comprised of conditions for ambient current velocity. Application of these models is done in Cheonsu Bay Summing up the results of this study are as follows; 1. It is found that the result for measurements of temperature appears high at southwardly Songdo on flood. The reason is that tidal currents which flowed north direction were accompanied with southwardly dispersed thermal discharge. A minute Particle of thermal Plume has a tendency to dispels inward Deacheon Bay. 2. According to the results of numerical experiment, maximum distance for thermal discharge dispersion appeared 10.8 km at lower part and 8.6 km at upper part with power plant outlet as starting point. 3. Comparative the numerical simulation and Airbone Multispectral Scanner indicated that thermal discharge should be verified separative phenomena. The simulated results were compared with field data set showing good agreement. It is concluded that these model can be simulated well.

  • PDF

A Study on the Thermal Behavior of Bearing Surroundings using State-Space in Machine Tool Spindle System (공작기계 스핀들시스템에서 상태공간을 이용한 베어링 주변의 열거동에 대한 연구)

  • 신동수;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1045-1049
    • /
    • 1995
  • This paper proposes the state-space model of the thermal behavior of the spindle system to establish dynamic mathematical model of thermal characteristics in machine tool spindle system. the model is derived form physical law of heat transfer and thermoelasticity and represents the thermal behavior induced by uneven thermal expansions whitin a bearing. The model, which is sucessfully validated for two typical configurations of high speed spindle assembles, provides a tool for understanding the basis mechanics of induced thermal expansion as a function of initial preload, spindle speed and housing cooling conditions.

  • PDF

Mathematical Simulation on Thermal Performance of Packed Bed Solar Energy Storage System (Packed Bed 태양에너지 저장시스템의 열성능에 관한 수학적 시뮬레이션)

  • KUMAR, ANIL;KIM, MAN-HOE
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.4
    • /
    • pp.331-338
    • /
    • 2015
  • Solar air heaters (SAHs) are simple in design and widely used for solar energy collection devices, and a packed bed is one of typical solar energy storage systems of thermal energy captured by SAHs. This paper presents mathematical modeling and simulation on the thermal performance of various packed bed energy storage systems. A MATLAB program is used to estimate the thermal efficiency of packed bed SAH. Among the various packed bed energy storage systems considered, the wire mesh screen packed bed SAH shows the best thermal efficiency over the entire range of design conditions. The maximum of thermal efficiency of packed bed SAH with wire mesh screen matrices has been found to be 0.794 for Re=2000 - 20000 and ${\Delta}T/I=0.002-0.02$.

Review : Thermal contact problems at cryogenic temperature

  • Jeong, Sangkwon;Park, Changgi
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • This paper addresses technical problems of thermal contact conductance or resistance which inevitably occurs in most cryogenic engineering systems. The main focus of this paper is to examine what kind of physical factors primarily influences the thermal contact resistance and to suggest how it can be minimized. It is a good practical rule that the contact surface must have sub-micron roughness level with no oxide layer and be thinly covered by indium, gold, or Apiezon-N grease for securing sufficient direct contact area. The higher contact pressure, the lower the thermal contact resistance. The general description of this technique has been widely perceived and reasonable engineering results have been achieved in most applications. However, the detailed view of employing these techniques and their relative efficacies to reduce thermal contact resistances need to be thoroughly reviewed. We should consider specific thermal contact conditions, examine the engineering requirements, and execute each method with precautions to fulfil their maximum potentials.

A Study on the Effect of the Thickness of Bond Coating on the Thermal Stresses of a Sprayed Thermal Barrier Coating (접착층의 두께가 용사 열차폐 코팅의 열응력에 미치는 영향에 관한 연구)

  • 김형남
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.221-227
    • /
    • 2001
  • Based on the principle of complementary energy, an analytical method is developed which focuses on the end effects for determining thermal stress distributions in a three-layered beam. This method gives the stress distributions which completely satisfy the stress-free boundary conditions. A numerical example is given in order to verify this method. The results show that the present analytical solutions have the values of stress in excellent agreement with the solutions derived by other investigators. Using this method, the effects of the thickness of bond coat on the thermal stresses of a typical sprayed thermal barrier coating, which consists of IN738LC substrate, MCrAIY bond coat and ZrO$_2$-8wt%Y$_2$O$_3$top coat, were investigated.

  • PDF

Algorithm of Thermal Error Compensation for the Line Center - System Interface - (CNC공작기계의 열변형 오차보정 (II) - 알고리즘 및 시스템 인터폐이스 중심 -)

  • 이재종;최대봉;박현구;류길상
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.417-422
    • /
    • 2002
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. In this study, the compensation device and temperature-based algorithm have been implemented on the machining center in order to compensate thermal error of machine tools under the real-time. The thermal errors are predicted using the neural network and multi-regression modeling methods. In order to compensate thermal characteristics under several operating conditions, experiments performed with five gap sensors and manufactured compensation device on the horizontal machining center.

  • PDF

Thermal effect on axisymmetric bending of functionally graded circular and annular plates using DQM

  • Hamzehkolaei, N. Safaeian;Malekzadeh, P.;Vaseghi, J.
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.341-358
    • /
    • 2011
  • This paper presents the effects of thermal environment and temperature-dependence of the material properties on axisymmetric bending of functionally graded (FG) circular and annular plates. The material properties are assumed to be temperature-dependent and graded in the thickness direction. In order to accurately evaluate the effect of thermal environment, the initial thermal stresses are obtained by solving the thermoelastic equilibrium equations. Governing equations and the related boundary conditions, which include the effects of initial thermal stresses, are derived using the virtual work principle based on the elasticity theory. The differential quadrature method (DQM) as an efficient and robust numerical tool is used to obtain the initial thermal stresses and response of the plate. Comparison studies with some available results for FG plates are performed. The influences of temperature rise, temperature-dependence of material properties, material graded index and different geometrical parameters are carried out.