• 제목/요약/키워드: Thermal boundary layer

검색결과 256건 처리시간 0.024초

Entropy Generation Minimization in MHD Boundary Layer Flow over a Slendering Stretching Sheet in the Presence of Frictional and Joule Heating

  • Afridi, Muhammad Idrees;Qasim, Muhammad;Khan, Ilyas
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1303-1309
    • /
    • 2018
  • In the present paper, we study the entropy analysis of boundary layer flow over a slender stretching sheet under the action of a non uniform magnetic field that is acting perpendicular to the flow direction. The effects of viscous dissipation and Joule heating are included in the energy equation. Using similarity transformation technique the momentum and thermal boundary layer equations to a system of nonlinear differential equations. Numerical solutions are obtained using the shooting and fourth-order Runge-Kutta method. The expressions for the entropy generation number and Bejan number are also obtained using a suggested similarity transformation. The main objective of this article is to investigate the effects of different governing parameters such as the magnetic parameter ($M^2$), Prandtl number (Pr), Eckert number (Ec), velocity index parameter (m), wall thickness parameter (${\alpha}$), temperature difference parameter (${\Omega}$), entropy generation number (Ns) and Bejan number (Be). All these effects are portrayed graphically and discussed in detail. The analysis reveals that entropy generation reduces with decreasing wall thickness parameter and increasing temperature difference between the stretching sheet and the fluid outside the boundary layer. The viscous and magnetic irreversibilities are dominant in the vicinity of the stretching surface.

Tropical Night (Nocturnal Thermal High) in the Mountainous Coastal City

  • Choi, Hyo
    • 한국환경과학회지
    • /
    • 제13권11호
    • /
    • pp.965-985
    • /
    • 2004
  • The investigation of driving mechanism for the formation of tropical night in the coastal region, defined as persistent high air temperature over than 25$^{\circ}C$ at night was carried out from August 14 through 15, 1995. Convective boundary layer (CBL) of a 1 km depth with big turbulent vertical diffusion coefficients is developed over the ground surface of the inland basin in the west of the mountain and near the top of the mountain, while a depth of thermal internal boundary layer (TIBL) like CBL shrunken by relatively cool sea breeze starting at 100 km off the eastern sea is less than 150 m from the coast along the eastern slope of the mountain. The TIBL extends up to the height of 1500 m parallel to upslope wind combined with valley wind and easterly sea breeze from the sea. As sensible heat flux convergences between the surface and lower atmosphere both at the top of mountain and the inland coast are much greater than on the coastal sea, sensible heat flux should be accumulated inside both the TIBL and the CBL near the mountain top and then, accumulated sensible heat flux under the influence of sea breeze circulation combined with easterly sea breeze from sea to inland and uplifted valley wind from inland to the mountain top returning down toward the eastern coastal sea surface should be transported into the coast, resulting in high air temperatures near the coastal inland. Under nighttime cooling of ground surface after sunset, mountain wind causes the daytime existed westerly wind to be an intensified westerly downslope wind and land breeze further induces it to be strong offshore wind. No sensible heat flux divergence or very small flux divergence occurs in the coast, but the flux divergences are much greater on the top of the mountain and along its eastern slope than on the coastal inland and sea surfaces. Thus, less cooling down of the coastal surface than the mountain surface and sensible heat transfer from warm pool over the coast into the coastal surface produce nocturnal high air temperature on the coastal inland surfaces, which is not much changed from daytime ones, resulting in the persistence of tropical night (nocturnal thermal high) until the early in the morning.

부산지역 빌딩 분포 상세화에 따른 중규모 순환 특성 (Characteristics of Mesoscale Circulation with the Detailed Building Distribution in Busan Metropolitan Area)

  • 손정옥;이화운;이순환
    • 한국환경과학회지
    • /
    • 제21권2호
    • /
    • pp.203-215
    • /
    • 2012
  • In order to clarify the impacts of thermal difference in atmospheric boundary layer due to the different sophistication of building information in Busan metropolitan areas, several numerical simulations were carried out. ACM (Albedo Calculation Model) and WRF (Weather Research and Forecasting) was applied for estimating albedo and meteorological elements in urban area, respectively. In comparison with coarse aggregated and small buildings, diurnal variation of albedo is highly frequent and its total value tend to be smaller in densely aggregated and tall buildings. Estimated TKE and sensible heat flux with sophisticatedly urban building parameterization is more resonable and valid values are mainly induced by urban building sophistication. The simulation results suggest that decreased albedo and increased roughness due to skyscraper plays an important role in the result of thermal change in atmospheric boundary layer.

Stress Analysis in Polymeric Coating Layer Deposited on Rigid Substrate

  • Lee, Sang Soon
    • Corrosion Science and Technology
    • /
    • 제14권4호
    • /
    • pp.161-165
    • /
    • 2015
  • This paper presents an analysis of thermal stress induced along the interface between a polymeric coating layer and a steel substrate as a result of uniform temperature change. The epoxy layer is assumed to be a linear viscoelastic material and to be theromorheologically simple. The viscoelastic boundary element method is employed to investigate the behavior of interface stresses. The numerical results exhibit relaxation of interface stresses and large stress gradients, which are observed in the vicinity of the free surface. Since the exceedingly large stresses cannot be borne by the polymeric coating layer, local cracking or delamination can occur at the interface corner.

종횡비 가 낮은 직각밀폐용기내 의 Prandtl 수 가 큰 유체 의 자연대류 에 관한 실험적 연구 (High prandtl number natural convection in a low-aspect ratio rectangular enclosure)

  • 이진호;황규석;현명택
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.750-756
    • /
    • 1985
  • 본 연구에서는 종횡비 0.1이고 상.하 수평경계면이 단열된 직각밀폐용기내에 서 Pr수가 1보다 큰 물(Pr=6.97, 20.deg. C) 및 실리콘 오일(Pr=1086.42, 20.deg. C)의 양단의 온도차에 의한 자연대류에서 아직 충분히 연구되지 않은 코어형상에 주안점을 두고 실 험적으로 관찰, 조사하였으며 그 결과를 Lee의 이론적인 예측과도 비교, 검토해 보았 다.

항공우주용 리오셀계 탄소/페놀릭 복합재료의 내열 성능 평가 (Evaluation of Heat Resistance of Lyocell-based Carbon/Phenolic for Aerospace)

  • 서상규;김연철;배지열;함희철;황태경
    • 한국항공우주학회지
    • /
    • 제49권5호
    • /
    • pp.355-363
    • /
    • 2021
  • 리오셀계 탄소/페놀릭 복합재료의 항공우주용 내열 부품 적용 가능성을 확인하기 위하여 내열성능 평가 및 열 해석을 수행하였다. 탄소/페놀릭의 열반응 평가는 내열성능평가모터(Thermal Protection Evaluation Motor, TPEM)로 수행되었다. 본 논문에서는 열 해석을 위해 유체의 경계층 해석을 고려한 경계층 적분 코드와 삭마 및 열분해를 고려한 MSC-Marc 2018 코드를 사용하였다. 추진기관의 압력 곡선, 연소 시험 후 절개된 목삽입재 시편을 통하여 삭마 및 단열성능을 분석하였고, 리오셀계 탄소/페놀릭 복합재료의 열반응은 레이온계 탄소/페놀릭 재료와 유사하였다. 연소시험을 통한 결과를 바탕으로 국산 리오셀계 탄소/페놀릭의 항공우주용 내열 부품으로의 적용 가능성을 확인하였다.

Assessment of negative Poisson's ratio effect on thermal post-buckling of FG-GRMMC laminated cylindrical panels

  • Shen, Hui-Shen;Xiang, Y.
    • Advances in nano research
    • /
    • 제10권5호
    • /
    • pp.423-435
    • /
    • 2021
  • This paper examines the thermal post-buckling behaviors of graphene-reinforced metal matrix composite (GRMMC) laminated cylindrical panels which possess in-plane negative Poisson's ratio (NPR) and rest on an elastic foundation. A panel consists of GRMMC layers of piece-wise varying graphene volume fractions to obtain functionally graded (FG) patterns. Based on the MD simulation results, the GRMMCs exhibit in-plane NPR as well as temperature-dependent material properties. The governing equations for the thermal post-buckling of panels are based on the Reddy's third order shear deformation shell theory. The von Karman nonlinear strain-displacement relationship and the elastic foundation are also included. The nonlinear partial differential equations for GRMMC laminated cylindrical panels are solved by means of a singular perturbation technique in associate with a two-step perturbation approach and in the solution process the boundary layer effect is considered. The results of numerical investigations reveal that the thermal post-buckling strength for (0/90)5T GRMMC laminated cylindrical panels can be enhanced with an FG-X pattern. The thermal post-buckling load-deflection curve of 6-layer (0/90/0)S and (0/90)3T panels of FG-X pattern are higher than those of 10-layer (0/90/0/90/0)S and (0/90)5T panels of FG-X pattern.

로켓노즐에 장착된 제트베인 표면의 열전달 특성 (Heat Transfer on a Jet Vane Surface Installed in a Rocket Nozzle)

  • 유만선;조형희;황기영;배주찬
    • 한국추진공학회지
    • /
    • 제9권1호
    • /
    • pp.9-16
    • /
    • 2005
  • 제트베인은 로켓추진기관의 발사초기 자세제어와 조정 안정성의 확보를 위해 로켓노즐 출구부에 장착되어지며, 발사 수초 후까지 연소가스와의 접촉으로 인해 구동부를 가열시키고, 그 자체도 화학적 혹은 기계적으로 삭마된다. 본 연구는 제트베인의 열해석을 위한 기초연구로서 균일 초음속 유동장내에 위치한 단일 제트베인으로의 열전달 특성 해석을 수행하여 보았다. 경계층 적분법과 유한차분법의 연립해석이 이루어 졌으며, 벽근방에서 도출된 경계조건을 바탕으로 베인 내부의 비정상 열전도 해석도 수행되었다.