• 제목/요약/키워드: Thermal boundary layer

검색결과 256건 처리시간 0.026초

통상 및 미소 중력의 초임계 압력하에서 일차원 액적 배열의 화염 퍼짐 거동의 비교 연구 (Comparative Study of Flame Spread Behaviors in One Dimensional Droplet Array Under Supercritical Pressures of Normal Gravity and Microgravity)

  • 박정;신현동;코바야시 히데아키;니오카 다카시
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.140-148
    • /
    • 1999
  • Experiments on flame spread in an one-dimensional droplet array up to supercritical pressures of fuel droplet have been conducted In normal gravity and microgravity. Evaporating process around unburnt droplet is observed through high-speed Schlieren and direct visualizations in detail, and flame spread rate is measured using high speed chemiluminescence images of OH radical. Flame spread behaviors are categorized into three: flame spread is continuous at low pressures and is regularly intermittent up to the critical pressure of fuel. flame spread is irregularly intermittent and zig-zag at supercritical pressures of fuel. At atmospheric pressure, the limit droplet spacing and the droplet spacing of maximum flame spread rate in microgravity are larger than those in normal gravity. In microgravity, the flame spread rate with the increase of ambient pressure decreases initially, takes a minimum, and then decreases after taking maximum. This is so because the flame spread time is determined by competing effects between the increased transfer time of thermal boundary layer due to reduced flame diameter and the reduced ignition delay time in terms of the increase of ambient pressure. Consequently, it is found that flame spread behaviors in microgravity are considerably different from those in normal gravity due to the absence of natural convection.

A summertime near-ground velocity profile of the Bora wind

  • Lepri, Petra;Kozmar, Hrvoje;Vecenaj, Zeljko;Grisogono, Branko
    • Wind and Structures
    • /
    • 제19권5호
    • /
    • pp.505-522
    • /
    • 2014
  • While effects of the atmospheric boundary layer flow on engineering infrastructure are more or less known, some local transient winds create difficulties for structures, traffic and human activities. Hence, further research is required to fully elucidate flow characteristics of some of those very unique local winds. In this study, important characteristics of observed vertical velocity profiles along the main wind direction for the gusty Bora wind blowing along the eastern Adriatic coast are presented. Commonly used empirical power-law and the logarithmic-law profiles are compared against unique 3-level high-frequency Bora measurements. The experimental data agree well with the power-law and logarithmic-law approximations. An interesting feature observed is a decrease in the power-law exponent and aerodynamic surface roughness length, and an increase in friction velocity with increasing Bora wind velocity. This indicates an urban-like velocity profile for smaller wind velocities and rural-like velocity profile for larger wind velocities, which is due to a stronger increase in absolute velocity at each of the heights observed as compared to the respective velocity gradient (difference in average velocity among two different heights). The trends observed are similar during both the day and night. The thermal stratification is near neutral due to a strong mechanical mixing. The differences in aerodynamic surface roughness length are negligible for different time averaging periods when using the median. For the friction velocity, the arithmetic mean proved to be independent of the time record length, while for the power-law exponent both the arithmetic mean and the median are not influenced by the time averaging period. Another issue is a large difference in aerodynamic surface roughness length when calculating using the arithmetic mean and the median. This indicates that the more robust median is a more suitable parameter to determine the aerodynamic surface roughness length than the arithmetic mean value. Variations in velocity profiles at the same site during different wind periods are interesting because, in the engineering community, it has been commonly accepted that the aerodynamic characteristics at a particular site remain the same during various wind regimes.

Effect of Plasma Pretreatment on Superconformal Cu Alloy Gap-Filling of Nano-scale Trenches

  • 문학기;이정훈;이수진;윤재홍;김형준;이내응
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.53-53
    • /
    • 2011
  • As the dimension of Cu interconnects has continued to reduce, its resistivity is expected to increase at the nanoscale due to increased surface and grain boundary scattering of electrons. To suppress increase of the resistivity in nanoscale interconnects, alloying Cu with other metal elements such as Al, Mn, and Ag is being considered to increase the mean free path of the drifting electrons. The formation of Al alloy with a slight amount of Cu broadly studied in the past. The study of Cu alloy including a very small Al fraction, by contrast, recently began. The formation of Cu-Al alloy is limited in wet chemical bath and was mainly conducted for fundamental studies by sputtering or evaporation system. However, these deposition methods have a limitation in production environment due to poor step coverage in nanoscale Cu metallization. In this work, gap-filling of Cu-Al alloy was conducted by cyclic MOCVD (metal organic chemical vapor deposition), followed by thermal annealing for alloying, which prevented an unwanted chemical reaction between Cu and Al precursors. To achieve filling the Cu-Al alloy into sub-100nm trench without overhang and void formation, furthermore, hydrogen plasma pretreatment of the trench pattern with Ru barrier layer was conducted in order to suppress of Cu nucleation and growth near the entrance area of the nano-scale trench by minimizing adsorption of metal precursors. As a result, superconformal gap-fill of Cu-Al alloy could be achieved successfully in the high aspect ration nanoscale trenches. Examined morphology, microstructure, chemical composition, and electrical properties of superfilled Cu-Al alloy will be discussed in detail.

  • PDF

기주의 열음향진동에 관한 연구 (A Study on the Thermoacoustic Oscillation of an Air Column)

  • 권영필;이병호
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.253-261
    • /
    • 1987
  • 본 논문에서는 이러한 점들을 보완하여 Fig.1에 도시한 Rijke 관에서 나선형 가열기에 의한 음향력의 발생량을 계산하고 기주진동을 일으키는데 필요한 가열량을 계산하고 기주진동을 일으키는데 필요한 가열량을 구하였다. 이론을 뒷받침하기 위 하여 실험을 하고 결과를 비교 검토하였다.

The effects of activated cooler power on the transient pressure decay and helium mixing in the PANDA facility

  • Kapulla, R.;Paranjape, S.;Fehlmann, M.;Suter, S.;Doll, U.;Paladino, D.
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2311-2320
    • /
    • 2022
  • The main outcomes of the experiments H2P6 performed in the thermal-hydraulics large-scale PANDA facility at PSI in the frame of the OECD/NEA HYMERES-2 project are presented in this article. The experiments of the H2P6 series consists of two PANDA tests characterized by the activation of three (H2P6_1) or one (H2P6_2) cooler(s) in an initially stratified and pressurized containment atmosphere. The initial stratification is defined by a helium-rich region located in the upper part of the vessel and a steam/air atmosphere in the lower part. The activation of the cooler(s) results i) in the condensation of the steam in the vicinity of the cooler(s), ii) the corresponding activation of large scale natural circulation currents in the vessel atmosphere, with the result of iii) the re-distribution and mixing of the Helium stratification initially located in the upper half of the vessel and iv) the continuous pressure decay. The initial helium layer represents hydrogen generated in a postulated severe accident. The main question to be answered by the experiments is whether or not the interaction of the different, localized cooler units would be important for the application of numerical methods. The paper describes the initial and boundary conditions and the experimental results of the H2P6 series with the suggestion of simple scaling laws for both experiments in terms of i) the temperature difference(s) across the cooler(s), ii) the transient steam and helium content and iii) the pressure decay in the vessel. The outcomes of this scaling indicate that the interaction between separate, closely localized units does not play a prominent role for the present experiments. It is therefore reasonable to model several units as one large component with equivalent heat transfer area and total water flow rate.

박막 두께 및 열처리가 수직자기이방성을 갖는 CoSiB/Pd 다층박막의 자기적 특성에 미치는 영향 (Influence of Layer-thickness and Annealing on Magnetic Properties of CoSiB/Pd Multilayer with Perpendicular Magnetic Anisotropy)

  • 정솔;임혜인
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.76-80
    • /
    • 2016
  • CoSiB은 비정질 구조를 갖는 강자성체 물질이며, CoSiB과 Pd을 포함한 다층박막은 수직자기이방성을 갖는다. 수직자기이방성은 수평자기이방성에 비해 STT-MRAM에 적용되기에 좋은 이점이 있으며, 특히 비정질 강자성체를 포함한 다층박막은 결정질강자성체를 포함한 다층박막과 비교하여 몇 가지 이점을 지니는데, 첫째는 grain boundary가 없다는 것이며 둘째는 결정질 재료에 비교하여 열적안정성이 보다 좋다는 것이다. 이러한 이유에 따라 우리는 비정질 강자성체 $Co_{75}Si_{15}B_{10}$을 포함하는 다층박막을 제작하여 그 자기적 특성을 연구하였다. 본 연구는 [CoSiB(3, 4, 5, 6) ${\AA}$/Pd(11, 13, 15, 17, 19, 24${\AA})]_5$ 다층박막을 제작하여 VSM 측정을 통해 두께에 따른 그 자기적 특성의 변화를 살펴보았으며, 이후 일부 다층박막의 열처리를 통해 온도에 따른 자기적 특성의 변화추이를 조사하였다. 포화자화값과 보자력은 CoSiB과 Pd 각 층의 두께 변화에 따라 증가와 감소를 반복하였으며, 열처리 온도의 범위는 상온에서 $500^{\circ}C$까지로 특정 온도에서 보자력의 증대를 보였다.

다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석 (Numerical analysis for heat transfer and pressure drop characteristics of )

  • 후영영;박형선;윤준규;임종한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.367-375
    • /
    • 2014
  • 셀-튜브 열교환기는 산업분야에서 가장 널리 사용되는 열교환기이다. 열교환기의 열적 성능을 개선하기 위하여 셀-튜브 열교환기에 대해 배플의 배치, 배플의 방향, 배플의 표면의 돌기형상 등의 인자를 변경하였으며, 유동의 박리 및 경계층해석에 적절히 이용되는 SST 난류모델을 적용하여 열전달특성을 고찰하였다. CFD해석시 경계조건는 셀측의 입구온도를 344K로 일정하게 하고, 물의 유량을 6, 12, 18, 24 l/min로 변화시켰다. 그 결과로는 지그재그형 배치가 열전달률 및 압력강하가 향상되는 것으로 나타났으며, 배플의 방향은 기존형보다 수직형 및 각도 $45^{\circ}$형이 열전달이 향상되는 것으로 나타났고, 압력강하는 거의 차이가 없었다. 또한 배플의 돌기형상은 열전달면적을 증가시킴으로써 열전달률 및 압력강하가 향상됨을 알 수 있었다. 해석결과를 통하여 열전달 증가가 유동의 박리, 유체의 체류시간, 튜브와의 접촉면적, 유량, 와류 등에 따라 크게 영향을 받는다는 것을 알 수 있었다.

순산소 분위기에서 촤 연소 및 질소산화물 배기특성 비교 (Comparative Study of Char Burn-Out and NOx Emissions in O2/N2 and O2/CO2 environments)

  • 이천성;김성곤;이병화;장영준;전충환;송주헌
    • 에너지공학
    • /
    • 제20권3호
    • /
    • pp.191-199
    • /
    • 2011
  • 본 연구에서는 Drop Tube Furnace(DTF)를 이용한 $O_2/N_2$, $O_2/CO_2$ 조건에서 산소 농도(12, 21, 31%)에 따른 아역청탄 입자의 연소특성 및 질소산화물 배출특성에 관한 실험과 수치해석을 수행하였다. $O_2/N_2$, $O_2/CO_2$ 조건에서 산소 농도가 증가함에 따라 촤 연소율이 증가하였고 $O_2/CO_2$ 조건하에서 이산화탄소 경계층에서 석탄입자 표면으로의 산소 확산계수가 낮아지기 때문에 촤 연소율이 감소하였다. 산소 농도가 증가함에 따라 배출되는 NO의 농도는 증가하지만 완전 연소 조건인 31%의 산소 농도에서는 오히려 NO의 농도가 감소하였다. 반면, NO 배출 지수는 산소가 증가함에 따라 점차 감소하였다. $O_2/CO_2$ 조건에서 NO의 농도는 Thermal NO의 결여로 인해 $O_2/N_2$ 조건보다 작게 나타났다.

대향류 확산화염에서 맥동 불안정성의 비선형 거동에 대한 수치해석 (Numerical Simulations of Nonlinear Behaviors of Pulsating Instabilities in Counterflow Diffusion Flames)

  • 이수룡
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.859-866
    • /
    • 2010
  • 대향류 확산화염에서 확산-전도 불안정성에 의한 맥동불안정성의 비선형 거동을 수치 해석적으로 연구하였다. Lewis 수를 1보다 충분히 크게 두고 일차원 준정상상태의 화염의 해로부터 Damkohler 수를 섭동시켜 시간에 따른 화염의 전개를 계산하였다. 맥동 불안정성에 의한 비선형 화염전개는 세 가지 다른 형태, 즉 교란이 점점 감소되는 경우, 교란이 증폭되어 안정된 주기적 진동이 일어나는 경우, 그리고 교란이 계속 증폭되어 화염이 소염되는 경우 등으로 나타났다. 스트레치를 받지 않는 화염의 결과와 달리 대향류 유동장의 화염에서는 안정된 한계순환 맥동 불안정이 존재하였다. 세 가지 다른 형태의 화염 전개를 보이는 임계 Damkohler 수를 계산하여 동적 소염이 일어나는 영역을 표시하였고, 이는 층류소화염의 국소소염 계산에 이용될 수 있다. 불안정성이 나타나는 갈래질의 구조는 초임계 및 임계이하 Hopf 갈래질로 나타났다. 특정한 Damkohler 수의 영역에서 안정된 한계 순환 갈래질이 나타났으며, 화염온도가 증가함에 따라 영역이 축소되어 안정된 한계순환이 일어나는 영역은 사라지고 불안정한 한계순환 갈래질이 나타났다. 안정된 한계순환 영역이 확장되는 영역이 존재하며, 이는 단순한 한계순환 불안정성이 주기배증에 의한 Rossler 갈래질이 나타나면서 한계 영역이 확장되었다.

서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구 (Analysis of thermal changes in bone by various insertion torques with different implant designs)

  • 김민호;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.168-176
    • /
    • 2011
  • 연구 목적: 임플란트 식립시에 발생할 수 있는 열변화는 임플란트의 실패를 초래할 수 있다. 식립토크에 따른 열변화 양상을 파악함으로 임플란트의 형태에 따른 차이점과 적절한 식립토크가 어떤 것인지 파악하고자 한다. 연구 재료 및 방법: 실험재료로는 두께 15 - 20 mm의 소 견갑골을 가로 35 mm, 세로 40 - 50 mm 크기가 되도록 골편으로 자르고 이중에 피질골의 두께가 2 - 3 mm 되는 표본을 선정한 후 표본의 반을 $36.5^{\circ}C$ 수조에 실온 $25^{\circ}C$에 노출 시켜 내부 온도는 평균 $36.5^{\circ}C$, 표면온도 $28^{\circ}C$가 되도록 설계하였다. $4.5{\times}10\;mm$의 외부육각을 가지는 Br${\aa}$nemark 형태의 임플란트와 $4.8{\times}10\;mm$의 Microthread 형태를 지니는 내부연결 형태의 임플란트를 과도한 식립토크로 식립하고 온도 측정은 계측점에서 0.2 mm 이내에 열전대를 위치시켜 기록하였다. 삼차원유한요소 분석은 골의 형태를 가로 4 cm, 세로 4 cm, 높이 2 cm의 직육면체로 가정하고, 직육면체 윗면에서 2 mm까지를 피질골, 그 아랫부분을 해면골이라고 가정하였다. 마찰열은 매식이 종료된 상황에서 골에 남는 cavity 모양을 기초로 경계조건을 부여하였다. CAD 프로그램인 SolidWorks 소프트웨어를 이용하였고, 이를 유한요소 구조해석용 프로그램인 Abaqus 6.9-1로 불러들여 해석하였다. 결과 및 결론: In vitro실험에서 Microthread type의 임플란트가 상대적으로 더 높은 최고점 온도를 보여주고 있으며 이는 임플란트의 형태에 따른 마찰열 발생이 주요 원인으로 보인다. 유한요소분석을 통해 살펴본 결과 Br${\aa}$nemark 형태의 임플란트의 경우 50 Ncm이상에서 Microthread를 가지는 형태의 경우에는 35 Ncm이상에서 Eriksson 등이 보고한 역치를 초과하는 온도가 발생하였다. 이를 통해 볼 때 Microthread type 이 식립토크에 따른 온도 증가가 더 민감함을 알 수 있다. 실험결과를 통해서 서로 다른 형태의 임플란트 식립시에 임플란트의 형태에 따라 적절한 삽입토크를 부여하는 것이 성공적인 임플란트 시술에 중요한 요소 중에 하나임을 알 수 있었다. 특히 Microthread를 갖는 임플란트 형태는 높은 초기고정성을 얻을 수 있다는 장점이 있는 반면 과도한 식립 토크로 인한 열 손상 가능성을 가질 수 있으므로 골량과 골질의 신중한 평가와 적절한 수술기법이 필요할 것으로 생각된다.