Structural and Dielectric Properties of (Sr.Ca)$TiO_3$-based Ceramics with the Substitution of Ca (Ca 치환에 따른 (Sr.Ca)$TiO_3$계 세라믹스의 구조적 및 유전 특성)

  • 최운식;강재훈;서용진;김창일;김충혁;박용필
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.879-884
    • /
    • 2001
  • In this paper, the structural and dielectric properties of (Sr$_{l-x}$Ca$_{x}$)TiO$_3$ (0$\leq$x$\leq$0.2) -based grain boundary layer ceramics were investigated by XRD, SEM and HP4194A. The ceramics were fabricated by the conventional mixed oxide method. The sintering temperature and time were 1420~152$0^{\circ}C$ and 4 hours, respectively. The average grain size and the lattice constant were decreased with increasing content of Ca. The average grain size was increased with increase of sintering temperature. The relative density of all specimens was 96~98%. The 2nd Phase formed by the thermal diffusion of CuO from the surface leads to very excellent dielectric properties, that is, $\varepsilon$$_{r}$>50000, tan $\delta$<0.05, $\Delta$C<$\pm$10%. The appropriate Ca content was under 15 ㏖%.s under 15 ㏖%.%.

  • PDF

Numerical Modeling of Heat Transfer Due to Particle Impact on a Wall (벽면에서의 입자 고찰에 의한 열전달 수치 모델)

  • 권오붕
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.3
    • /
    • pp.296-305
    • /
    • 1995
  • A numerical study was undertaken to clarify the mechanisms of heat transfer in fluid-particle suspension flows. Such flows, including fluidization, are of considerable industrial importance. The present study uses 2-D numerical computations of collisions of normal incidence between a particle and a wall. By comparing the results using (a) adiabatic boundary conditions on the particle and (b) uniform, elevated temperature conditions on the particle, the contributions of fluid-mediated conduction and particle induced convection were successfully separated. Computational expedience led to the use of a transient conduction thermal layer as the background thermal field for the analysis. The results shows that the effect of particle movement is very small until the particle reaches a distance of one to one half diameter away from the wall. The gas-mediated conduction effect is dominant over the induced gas convection effect when Pe is small and the induced gas convection effect becomes significant as Pe increases.

  • PDF

Analysis of the Influence of Urban Land Cover Changes on the Thermal Environment of the Atmospheric Boundary Layer Using Computational Fluid Dynamics Model (전산유체역학 모델을 이용한 도시 지표 피복 변화가 대기 경계층 열적 환경에 미치는 영향 분석)

  • Kim, Ji-Seon;Yoo, Jung-Woo;Na, Mun-Soo;Kim, Yong-Gil;Lee, Soon-Hwan
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1153-1170
    • /
    • 2020
  • With global warming and the rapid increase in urbanization accompanied by a concentration of population, the urban heat island effects (UHI) have become an important environmental issue. In this study, rooftop greening and permeable asphalt pavement were selected as measures to reduce urban heat island and applied to a simple virtual urban environment to simulate temperature change using ENVI-met. A total of five measures were tested by dividing the partial and whole area application of each measure. The results showed that the temperature range of the base experiment is 33.11-37.11 ℃, with the UTCI comfort level described as strong heat and very strong heat stress. A case applied permeable asphalt has a greater temperature difference than a rooftop greening case, the larger the area where each condition was applied, the greater the temperature change was.

Design of sinusoidal shape channel PCHEs for supercritical LNG based on CFD simulation (CFD 시뮬레이션 기반 초임계 LNG용 사인함수 PCHE 설계)

  • Fan, Jinxing;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.69-76
    • /
    • 2021
  • Printed circuit heat exchanger (PCHE) is a compact heat exchanger with good heat transfer performance, high structure integrity, and reliability over a wide range of temperatures and pressures. Instead of the traditional zigzag and straight shape channel, the sinusoidal shape channel was adopted in this study to investigate the relation of thermal-hydraulic performance and waviness factors (period and amplitude). The local flow characteristics and the heat flux distribution were compared to verify the effects of period and amplitude on heat transfer performance. As the period of channel becomes shorter, the rapid change of the flow direction can produce high flow separation around the corner leading to the disturbance of the boundary layer opposite wall. The nonuniform distribution of flow velocity appeared around the corner positions can promote fluid mixing and lead to higher thermal performance. An evaluation index was used to compare the comprehensive performance of PCHE considering the Nusselt number and Fanning factor. Based on the simulation results, the optimal design parameters of PCHE channel shape were found that the channel with an equivalent bending angle of 15° offers the highest heat flux capacity.

Large eddy simulation of turbulent flow using the parallel computational fluid dynamics code GASFLOW-MPI

  • Zhang, Han;Li, Yabing;Xiao, Jianjun;Jordan, Thomas
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1310-1317
    • /
    • 2017
  • GASFLOW-MPI is a widely used scalable computational fluid dynamics numerical tool to simulate the fluid turbulence behavior, combustion dynamics, and other related thermal-hydraulic phenomena in nuclear power plant containment. An efficient scalable linear solver for the large-scale pressure equation is one of the key issues to ensure the computational efficiency of GASFLOW-MPI. Several advanced Krylov subspace methods and scalable preconditioning methods are compared and analyzed to improve the computational performance. With the help of the powerful computational capability, the large eddy simulation turbulent model is used to resolve more detailed turbulent behaviors. A backward-facing step flow is performed to study the free shear layer, the recirculation region, and the boundary layer, which is widespread in many scientific and engineering applications. Numerical results are compared with the experimental data in the literature and the direct numerical simulation results by GASFLOW-MPI. Both time-averaged velocity profile and turbulent intensity are well consistent with the experimental data and direct numerical simulation result. Furthermore, the frequency spectrum is presented and a -5/3 energy decay is observed for a wide range of frequencies, satisfying the turbulent energy spectrum theory. Parallel scaling tests are also implemented on the KIT/IKET cluster and a linear scaling is realized for GASFLOW-MPI.

A Numerical Study on the Toxic Gaseous and Solid Pollutant Dispersion in an Open Atmosphere (고-기상 유해물질 대기확산에 관한 수치해석)

  • 이선경;송은영;장동순
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.146-154
    • /
    • 1994
  • A series of numerical calculations are performed in order to investigate the dispersion mechanism of toxic gaseous and solid pollutants in extremely short-term and short range. The calculations are carried out in an open space characterized by turbulent boundary layer. The simulation is made by the use of numerical model, in which a control-volume based finite difference method is used together with the SIMPLEC algorithm for the resolution of the pressure-velocity coupling problem. The Reynolds stresses are solved by two-equation, k-$\varepsilon$ model modified for buoyancy. The major parameters consider-ed in this study are temperature, velocity and Injection height of toxic gases, environmental conditions such as temperature and velocity of free stream air, and topographic factor. The results are presented and discussed in detail. The flow field is commonly characterized by the formation of a strong recirculation zone due to the upward motion of the hot toxic gas and ground shear stress. The driving force of the upward motion is explained by the effect of thermal buoyancy of hot gas and the difference of inlet velocity between toxic gas and free stream.

  • PDF

Direct Numerical Simulation of Turbulent Scalar Transport in a Channel with Wall Injection

  • Na, Yang
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.597-605
    • /
    • 2004
  • Turbulent temperature field in a channel subject to strong wall injection has been investigated via direct numerical simulation technique. These flows are pertinent to internal flows inside hybrid rocket motors. A simplified model problem where a regression process at the propellant surface is idealized by wall injection has been investigated to understand how the temperature field is modified. The effect of strong wall injection displaces thermal boundary layer away from the wall and this causes a sharp drop of friction temperature. Turbulent diffusivity and dissipation time scale for temperature field are found to show large variations in the streamwise direction under application of wall blowing. It is, thus, expected that more sophisticated turbulence models would be required to predict the disturbed temperature field accurately.

Numerical Study of Three-Dimensional Compressible Flow Structure Within an S-Duct for Aircraft Engine Inlet

  • Cho, Soo-Yong;Park, Byung-Kyu
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.1
    • /
    • pp.36-47
    • /
    • 2000
  • Three-dimensional compressible turbulent flow fields within the passage of a diffusing S-duct have been simulated by solving the Navier-Stokes equations with SIMPLE scheme. The average inlet Mach number is 0.6 and the Reynolds number based on the inlet diameter is $1.76{\times}10^6$ The extended $k-{\varepsilon}$ turbulence model is applied to modeling the Reynolds stresses. Computed results of the flow in a circular diffusing S-duct provide an understanding of the flow structure within a typical engine inlet system. These are compared with experimental wall static-pressure, total-pressure fields, and secondary velocity profiles. Additionally, boundary layer thickness, skin friction values, and streamlines in the symmetric plane are presented. The computed results depict the interaction between the low energy flow by the flow separation and the high energy flow by the reversed duct curvature. The computed results obtained using the extended $k-{\varepsilon}$ turbulence model.

  • PDF

Catalytically Stabilized Combustion Characteristics of Methane on Platinum Catalyst (백금 촉매에 의해 안정화된 메탄의 연소 특성)

  • Hwang, C.H.;Jeong, Y.S.;Lee, C.E.
    • 한국연소학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.152-161
    • /
    • 2000
  • The catalytically stabilized combustion of $CH_4$-air mixture on platinum catalyst was investigated numerically using a 2-D boundary layer model with detailed heterogeneous and homogeneous chemistries. The actual surface site density of monolith coated with platinum was decided by the comparison with experimental data. The comparisons were made between results for cases where only heterogeneous chemistry was allowed and both heterogeneous and homogeneous chemistries were allowed. It was found that the homogeneous reaction in the monolith had little effect on the change of temperature profile, methane conversion rate and light off location. The contributions of each reactions related with CO formation were discussed on the surface. The effects of operation conditions such as equivalence ratio, temperature, velocity and pressure at the entrance were studied. In thermal combustor, CO and NOx was produced less than 1 ppm at the exit and the production of $N_{2}O$ was more dominant than that of NO.

  • PDF

AN ANALYSIS OF THE CHIMNEY WALL

  • Yang, Young-Kyun
    • Korean Journal of Mathematics
    • /
    • v.7 no.1
    • /
    • pp.27-35
    • /
    • 1999
  • As seen from the ammonium chloride experiment (Chen & Chen [1], Roberts & Loper [11], the interface near chimneys has an up-rising shape and we observe thickening of mush next to chimney. We analyze the thermal boundary layer around chimney that forms as the mush is cooled locally by the fluid rising through the chimney. We obtain solutions of the temperature, the solid fraction, and the pressure in the chimney wall. Also, our expression of the pressure shows that the fluid flow can require a huge pressure in order to pass through the chimney wall if its permeability is very small. We present a simple analytic description of the up-rising shape near the exit of the chimney, due to the fact that the comparatively solute (i.e. $NH_4Cl$ in the case of the ammonium chloride experiment)-rich fluid near the chimney tends to crystallize as it is chilled by the rising jet of cold fluid in the chimney.