• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.031 seconds

Using and Evaluative Criteria for Purchasing of Sleepwear in Winter (겨울철 잠옷이용실태와 구매시 평가기준)

  • Kweon, Soo-Ae;Choi, Jong-Myoung;Kim, Eun-Young
    • Korean Journal of Human Ecology
    • /
    • v.10 no.1
    • /
    • pp.101-111
    • /
    • 2001
  • The purpose of this study was to investigate using and evaluative criteria for purchasing of sleepwear in winter. Subjects were 523 males and females aged from twenties to fifties, living in Chongju and Taejon. For data analysis, frequency, descriptive analysis, t-test, and F-test were used. The results are as follows. First, the ownership of sleepwear was sweat suits with zippered top, pajamas, T-shirts/pants, underwear, and nightgown in order. The mean of using sweat suits was used the highest, and subjects used more home wear than sleepwear in winter. Second, the using or sleepwear had a significant difference in cold-sensitiveness and body types. Cold-sensitive group used sweat suit and T-shirts/pants more than cold-insensitive group. Also, groups who are thin wore sweat suit the most while groups who are corpulent, used underwear the most when they slept. Third, subjects, who are married women and use bed, used nightgown, but pajamas were used by groups who are older, married, and professional. Sweat suits and T-shirts/pants were used the most by single aged twenties. Forth, consumers considered the wearing comfort when they purchased sleepwear for winter, and they evaluated washing/management, fabric, design/style, economic, service, brand, and others' response in order, for judging the quality of sleepwear. Also, the evaluative criteria had a significant difference in demographic variables such as sex, occupation, and marital state. These results implied that sleepwear would be needed for winter in terms of behavioral temperature regulation. Especially, cold-sensitive and thin group would wear knitted and two-piece sleepwear for thermal comfort when they sleep in winter. Also, Using and evaluative criteria of sleepwear would be different in demographic characteristics. For winter, sleepwear should be develop based on physiologic as well as demographic variables.

  • PDF

ANALYSIS OF TURBULENT BOUNDARY LAYER OF NATURAL CONVECTION CAUSED BY FIRE ALONG VERTICAL WALL (수직벽 화재 자연대류에 의한 난류 경계층 열유동 특성 해석)

  • Jang, Yong-Jun;Kim, Jin-Ho;Ryu, Ji-Min
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2016
  • The analysis of characteristics of turbulent flow and thermal boundary layer for natural convection caused by fire along vertical wall is performed. The 4m-high vertical copper plate is heated and kept at a uniform surface temperature of $60^{\circ}C$ and the surrounding fluid (air) is kept at $16.5^{\circ}C$. The flow and temperature is solved by large eddy simulation(LES) of FDS code(Ver.6), in which the viscous-sublayer flow is calculated by Werner-Wengle wall function. The whole analyzed domain is assumed as turbulent region to apply wall function even through the laminar flow is transient to the turbulent flow between $10^9$<$Gr_z$<$10^{10}$ in experiments. The various grids from $7{\times}7{\times}128$ to $18{\times}18{\times}128$ are applied to investigate the sensitivity of wall function to $x^+$ value in LES simulation. The mean velocity and temperature profiles in the turbulent boundary layer are compared with experimental data by Tsuji & Nagano and the results from other LES simulation in which the viscous-sublayer flow is directly solved with many grids. The relationship between heat transfer rate($Nu_z$) and $Gr_zPr$ is investigated and calculated heat transfer rates are compared with theoretical equation and experimental data.

Study on Improvement of Dimensional Accuracy of a Precision Plastic Screw Under Various Injection-Molding Conditions (사출성형 조건에 따른 정밀 플라스틱 나사의 형상정밀도 향상에 관한 연구)

  • Baek, Soon-Bo;Park, Keun;Youm, Chung-Ho;Ra, Seung-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1549-1554
    • /
    • 2010
  • Recently, plastic screws have replaced metal screws because of the former's light weight, thermal and electrical insulating properties, and anticorrosion characteristics. Plastic screws are usually produced by injection molding, which involves material shrinkage during the solidification of the polymer. This shrinkage results in the degeneration of the dimensional accuracy. In the present study, the effect of injection-molding conditions on the dimensional accuracy of plastic screws was investigated through a numerical simulation of injection molding; on the basis of this simulation, we could determine the mold-design parameters. The design of experiment was applied in accordance with the numerical analysis in order to optimize the injection-molding conditions with a view to improving the dimensional accuracy of the precision plastic screw.

Development a Two Step Heater Using Induction Heating Based on o High Frequency Resonant Inverter (고주파 공진형 인버터를 이용한 유도가열형 2단 히터)

  • Shin, Dae-Cheul;Kwon, Hyuk-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.81-86
    • /
    • 2005
  • Proposed induction-heated system is innovative system which applied special high-frequency power circuit technique for thermal converse technique and IH(Induction-Heating) magnetic induction heating generated from induction-heated metallic package that is for distillation unit. In this occurs not burning, so that the working environment can be improved. This electromagnetic induction heating technique is used high frequency inverter. By using high frequency inverter high frequency alternative current (HFAC) in the range of [kHz] can be made with conventional alternative current In this contribution IGBT module is used for high frequency inverter. In this paper are discussed action analysis and characteristics analysis of 1.5[kW]-Class half-bridge resonant inverter system and resonant metallic packaged. In addition, by using this system,t how two step heating superheated steam generator is developed and application of system are also discussed.

Numerical Analysis for Improving of SOx Removal Efficiency in the DSI(Dry Sorbent Injection Technique) of FGD System(I) (배연탈황 공정 중 DSI 공법의 탈황효율 향상을 위한 전산 유체 역학적 연구(I))

  • Chung, Jin-Do;Kim, Jang-Woo;Kim, Byung-Hwan;Park, Young-Moon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.47-53
    • /
    • 2007
  • The aim of this study is to research applicable possibility or Dry Sorbent Injection Technique(DSI) in sox removal process using Computational Fluid Dynamics(CFD) software package. It will be applied for 500MW in capacity coal-fired thermal power plant operated by South Korea N. Power Co., Ltd. The DSI process is adapted between a preheater and an EP process in the technological assembly. The numerical analysis performs in predicting and optimizing of DSI process's characteristics, which consists of structure of duct, position of injection nozzles, injection speed, and dispersion of sorbent. Computing results are shown that degree of sorbent dispersion depends on structure of duct and position of injection nozzles strongly. The highest dispersion efficiency was obtained when we set a Lobed-plate inside the duct and 6 injection nozzles on the duct(4 injection nozzles at the corners and 2 injection nozzles on upper and under walls as a rectangle duct shape). We also know that change of injection speed of sorbent doesn't have an large effect on the sorbent dispersion but it can effect to drop pressure.

Development a High-Efficiency Induction Heating Heater using a 5[kW] Class Full-Bridge High Frequency Resonant Inverter (5[kW]급 풀-브릿지 고주파 공진형 인버터를 이용한 고효율 유도가열 히터 개발)

  • Kwon Hyuk-Min;Shin Dae-Cheul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.481-487
    • /
    • 2005
  • Proposed induction-heated system is innovative system which applied special high-frequency power circuit technique for thermal converse technique and IH(Induction-Heating) magnetic induction heating generated from induction-heated metallic package that is for distillation unit. In this occurs not burning, so that the working environment can be improved. This electromagnetic induction heating technique is used high frequency inverter, By using high frequency inverter high frequency alternative current in the range of [kHz] can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. This paper proposes new fluid heating method. Which is operated as follows. Working coil, which is wrapped outside of pipeline, makes the eddy current. Inside of heating vessel in isolated pipeline the specially designed stainless metallic package is inserted, which can be heated by eddy current losses. And then In this paper are discussed action analysis and characteristics analysis of 5[kW] class full-bridge resonant inverter system and resonant metallic package. In addition, by using this system, how high-efficiency heater is developed and application of system are also discussed.

Characteristics of Kenaf Fibers Treated by Alkali (알칼리 처리에 따른 케나프 섬유의 특성 변화 연구)

  • Yoo, Hye-Ja;Lee, Hye-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.8
    • /
    • pp.982-990
    • /
    • 2011
  • Kenaf fiber can be obtained by decortications of the kenaf plant stem. The properties of the kenaf fiber treated by alkali (NaOH) were investigated by spectrocolorimeter, SEM, X-ray diffractometer, FT-IR and TGA. The kenaf fibers treated by alkali became darker and their Munsell color values changed from Y (yellow) to YR (yellowred) according to an increased NaOH concentration. SEM observation of the kenaf fibers showed that their crimps were developed and their surfaces were cleaned by the removal of protruding ends and impurities after alkali treatments. In the x-ray diffraction analysis, the structures of the fibers were found in the form of cellulose I when treated with a 0-16% alkali concentration and cellulose II when treated with over 20%. It was also confirmed that the crystallinity was lowered according to an increased NaOH concentration. The change of fiber compositions was investigated in FT-IR analysis. Strong band of $1,738cm^{-1}$ and asymmetrical stretching strong bands of $1,630-1,600cm^{-1}$ in spectrum (which represent pectin) were not found in the samples because the pectin was removed by the alkali treatment. Weak bands of $1,728-1,730cm^{-1}$ and peaks of $1,245-1,259cm^{-1}$ (which represent hemicellulose) and peaks of $1,592cm^{-1}$, $1,504cm^{-1}$, $1,462cm^{-1}$ and $1,429cm^{-1}$ (which are related to lignin) were not found or reduced in the samples treated with a concentration over 20%. TGA indicated that the kenaf fiber had the better hydrophilic properties by alkali treatment. The higher Tmax in TGA and the higher thermal stability when treated by alkali with the higher concentration. The fibers treated with an alkali concentration over 30% did not show any changes in Tmax.

Oxidation Characteristics of Methanol on Pt/C and Pt-Ru/C Catalyst for the Anode of Direct Methanol Fuel Cell (Pt/C 및 Pt-Ru/C 촉매를 사용한 직접 메탄올 연료전지 연료극의 메탄올 산화 반응 특성)

  • 정두환;이창형;신동열
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.35-43
    • /
    • 1998
  • Electrodes using for the anode electrode of direct methanol fuel cell with Pt/C and Pt/Ru/C catalyst were prepared and characterized by SEM, TEM, thermal analysis and electrochemical analysis. The half cell tests were carried out with 1 M $H_2SO_4$ electrolyte and 1 M $CH_3OH$ in order to evaluate the electrode performance. The employed electrochemical methods were cyclic vol-tammetry and potentiodynamic polarization experiments. It was found that 20 w% polytetrafluoroethylene (PTFE) content in catalyst showed the best performance due to the best platinum utilization on PTFE-containing catalyst layer. It was found that Pt/Ru/C binary catalyst inhibited the poisoning of anode electrode showing improved performance compared to the Pt/C catalyst by the adsorption of oxygen containing species on the electrode surface at same time. The apparent activation energy for methanol oxidation on the Pt/Ru/C and Pt/C catalyst layer was 11.60 kJ/mol and 26.85 kJ/mol, respectively.

  • PDF

Different Types of Active Region EUV Bright Points by Hinode/EIS

  • Lee, Kyoung-Sun;Moon, Yong-Jae;Kim, Su-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.28.2-28.2
    • /
    • 2010
  • We have investigated seven Extreme-Ultraviolet (EUV) bright points in the active region (AR 10926) on 2006 December 2 by the EUV imaging spectrometer (EIS) onboard Hinode spacecraft. We determined their Doppler velocities and non-thermal velocities from 15 EUV spectral lines (log T=4.7-7.2) by fitting each line profile to a Gaussian function. We present the Doppler velocity map as a function of temperature which corresponds to a different height. As a result, these active region bright points show two different types of characteristics. Type 1 bright point shows a systematic increase of Doppler velocity from -68 km/s (blue shift) at log T=4.7 to 27 km/s (red shift) at log T=6.7, while type 2 bright points have Doppler velocities in the range of -20 km/s and 20 km/s. Using MDI magnetograms, we found that only type 1 bright point was associated with the canceling magnetic feature at the rate of $2.4{\times}10^{18}$ Mx/hour. When assuming that these bright points are caused by magnetic reconnection and the Doppler shift indicates reconnection out flow, the pattern of the Doppler shift implies that type 1 bright point should be related to low atmosphere magnetic reconnection. We also determined electron densities from line ratio as well as temperatures from emission measure loci using CHIANTI atomic database. The electron densities of all bright points are comparable to typical values of active regions (log Ne=9.9-10.4). For the temperature analysis, the emission loci plots indicate that these bright points should not be isothermal though background is isothermal. The DEM analysis also show that while the background has a single peak distribution (isothermal), the EUV bright points, double peak distributions.

  • PDF

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.