• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.031 seconds

Development of a computer code for thermal-hydraulic design and analysis of helically coiled tube once-through steam generator

  • Zhang, Yaoli;Wang, Duo;Lin, Jianshu;Hao, Junwei
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1388-1395
    • /
    • 2017
  • The Helically coiled tube Once-Through Steam Generator (H-OTSG) is a key piece of equipment for compact small reactors. The present study developed and verified a thermal-hydraulic design and performance analysis computer code for a countercurrent H-OTSG installed in a small pressurized water reactor. The H-OTSG is represented by one characteristic tube in the model. The secondary side of the H-OTSG is divided into single-phase liquid region, nucleate boiling region, postdryout region, and single-phase vapor region. Different heat transfer correlations and pressure drop correlations are reviewed and applied. To benchmark the developed physical models and the computer code, H-OTSGs developed in Marine Reactor X and System-integrated Modular Advanced ReacTor are simulated by the code, and the results are compared with the design data. The overall characteristics of heat transfer area, temperature distributions, and pressure drops calculated by the code showed general agreement with the published data. The thermal-hydraulic characteristics of a typical countercurrent H-OTSG are analyzed. It is demonstrated that the code can be utilized for design and performance analysis of an H-OTSG.

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea ( I ) - Evaluation of Sampling and Analytical Methodology (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(I) - 측정 방법론 평가 -)

  • 백성옥;김미현;김수현;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.95-107
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the first part of the study, the performance of sampling and analytical methods was evaluated for the measurement of selected VOCs and carbonyl compounds in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis, while carbonyls by the DNPH-silica cartridge sampling with HPLC analysis. The methodology was investigated with a wide range of performance criteria such as repeatability, linearity. lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal standards. In addition, the sampling and analytical methods established in this study were applied to real field samples duplicately collected in various ambient environments. Precisions for the duplicate samples appeared to be comparable with the performance criteria recommended by USEPA TO-17. The overall precision of the sampling and analytical methods was estimated to be within 20 ∼ 30% for major aromatic VOCs such as BTEX, whereas the precision for major carbonyl compounds such as formaldehyde and acetaldehyde was within 10 ∼ 20% for field samples. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

Radical Addition Reaction of Phosphorous based Flame Retardant with End Groups of PET (2) - Reaction of Resorcinol bis(diphenyl phosphate) - (PET 말단에 대한 인계난연제의 라디칼계 부가반응 (2) - 리소시놀비스다이페닐포스페이트의 반응 -)

  • Kim, Min-Kwan;Sohn, Kwang-Ho;Ghim, Han-Do
    • Textile Coloration and Finishing
    • /
    • v.24 no.1
    • /
    • pp.39-44
    • /
    • 2012
  • To improve flame retardation of poly(ethylene terephthalate) (PET) against burning, resorcinol bis(diphenyl phosphate) (RDP), phosphorous containing flame retardant, was incorporated into PET backbone by radical reaction pathway. Radical endcapping of PET with RDP was confirmed by spectroscopic and thermal analysis. From 400 MHz $^{31}P$ solid state FT-NMR spectrum of PET with RDP (PET-RDP), phosphorus spectra peak in RDP was found at ca. -10 ppm. Furthermore, P-C bond stretching vibration peaks were found ca. $530cm^{-1}$ in FT-IR spectrums of PET-RDP. These results indicated that RDP can be chemically bound at the ends of PET by radical addition method. Thermal characteristics of pure PET (pPET) and PET-RDP were measured and evaluated by TGA thermal analysis. There was not significant changes in thermal characteristics of PET-RDP compared to that of pPET.

Numerical Study about Influence Variables of Permafrost Pipeline by using Thermal Flow Analysis (극한지 온도조건에 파이프라인 내부 열유동 영향변수 평가)

  • Jo, Chul H.;Hwang, Su-Jin;Jang, Choon-Man;Lee, Jun-Ho
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.4
    • /
    • pp.443-448
    • /
    • 2014
  • This paper describes thermal flow characteristics in various pipelines: straight pipeline and curved pipeline. In the permafrost area, pipelines are exposed to an extremely low temperature ($-40^{\circ}C$). In this situation, three-dimensional flow analysis should be analyzed to investigate thermal effects such as pressure drop, temperature change, velocity deficit and distribution change of liquid droplet of internal fluid. In this paper, multi-phase and multi-species analysis was introduced to analyze the flow characteristics of permafrost pipelines on the vertical support members above ground.

Numerical Investigation of On-orbit Thermal Characteristics for Cube Satellite with Passive Attitude Stabilization Method (수동형 자세제어 안정화 방식을 적용한 큐브위성의 열적 특성분석)

  • Oh, Hyun-Ung;Park, Tae-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.5
    • /
    • pp.423-429
    • /
    • 2014
  • Passive attitude stabilization methods using the permanent magnet combined with hysteresis damper and the gravity gradient boom have been widely used for the attitude determination and control of cube satellite, due to its advantage of system simplicity. In this paper, on-orbit thermal characteristics of the cube satellite considering the attitude profiles obtained from the above passive attitude stabilization methods have been investigated through on-orbit thermal analysis. In addition, the effectiveness of the various thermal coatings on the panel for the communication antenna installation has been verified.

Thermogravimetric and Fourier Transform Infrared Analysis of Switchgrass Pyrolysis (스위치그라스 열분해에 대한 TGA-FTIR 분석)

  • Lee, Seong-Beom;Fasina, Oladiran O.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • This study was conducted to investigate the pyrolysis characteristics of switchgrass using TGA-FTIR instrument. Switchgrass is a high yielding perennial grass that has been designated as a potential energy crop, because of its high energy value. Ground switchgrass were pyrolysed at different heating rates of 10, 20, 30, and $40^{\circ}C/min$ in a TGA-FTIR instrument. The thermal decomposition characteristics of switchgrass were analyzed, and the gases volatilized during the experiment were identified. The thermal decomposition of switchgrass started at approximately $220^{\circ}C$, followed by a major loss of weight, where the main volatilization occurred, and the thermal decomposition was essentially completed by $430^{\circ}C$. The pyrolysis process was found to compose of four stages; moisture evaporation, hemicellulose decomposition, cellulose decomposition, and lignin degradation. The peak temperatures for hemicellulose decomposition ($306^{\circ}C$ to $327^{\circ}C$) and cellulose decomposition ($351^{\circ}C$ to $369^{\circ}C$) were increased with greater heating rates. FTIR analysis showed that the following gases were released during the pyrolysis of switchgrass; $CO_2$, CO, $CH_4$, $NH_3$, COS, $C_{2}H_{4}$, and some acetic acid. The most gas species were released at low temperature from 310 to $380^{\circ}C$, which was corresponding well with the observation of thermal decomposition.

Heat Transfer Analysis of High Temperature Dish-type Solar Receiver with the Variation of Porous Material (다공성 매질의 형상 변화에 따른 접시형 고온 태양열 흡수기의 열성능 평가)

  • Lee, Ju-han;Seo, Joo-Hyun;Oh, Sang-June;Lee, Jin-Gyu;Cho, Hyun-Seok;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.238-244
    • /
    • 2008
  • A numerical and experimental studies are carried out to investigate the heat transfer characteristics of 5kWth dish-type solar air receiver. Measured solar radiation and temperatures at several different locations are used as boundary conditions for numerical simulation. Many parameters' effects (reflectivity of the reflector, the thermal conductivity of the receiver body, transmissivity of the quartz window, etc.) on the thermal performance are investigated. Discrete Transfer Method is used to calculate the radiation heat exchange in the receiver. A heat transfer model is developed and the rate of radiation, convection and conduction heat transfer are calculated. Using the numerical model, the heat transfer characteristics of volumetric air receiver for dish-type solar thermal systems are known and the thermal performance of the receiver can be estimated.

  • PDF

Computational Heat Transfer Analysis of Dish Type Solar Receiver Using the Transient model (CFD를 이용한 접시형 태양열 집열기의 과도 열전달 모델 해석)

  • Oh, Sang-June;Lee, Ju-Han;Seo, Joo-Hyun;Lee, Jin-Gyu;Cho, Hyun-Seok;Seo, Tae-Beom
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.72-79
    • /
    • 2008
  • A numerical and experimental studies are carried out to investigate the transient heat transfer characteristics of 5kWth dish type solar air receiver. Measured solar radiation and temperatures at several different locations are used as boundary conditions for numerical a. Many parameters' effects (reflectivity of the reflector, the thermal conductivity of the receiver body, transmissivity of the quartz window, etc.) on the thermal performance are investigated. Discrete Transfer Method is used to calculate the radiation heat exchange in the receiver. A transient heat transfer model is developed and the rate of radiation, convection and conduction heat transfer are calculated. Comparing of the experimental and the numerical results, results of both are in good agreement. Using the numerical model, the transient heat transfer characteristics of volumetric air receiver for dish type solar thermal systems are known and the transient thermal performance of the receiver can be estimated.

  • PDF

Flammability Characteristics of Unsaturated Polyesters for FRP (FRP용 불포화폴리에스터 수지들의 연소 특성 연구)

  • 최원종
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.51-57
    • /
    • 1998
  • The thermal behavior and the flammability characteristics of four different unsaturated polyester resins were studied by performing a series of thermal analysis experiments and laboratory scale fire tests. The results of TGA and DSC reveals that the vinylester type resins have superior thermal performances when compared to the isophthalic type resins. The vinylester type resins formed a network shaped char surface after the thermal decomposition up to 55$0^{\circ}C$. Consequently, the vinylester type resings have shown lower value of burning rate than that of iso type resins. Due to the high level of flammability and toxic smoke emission, the appropriate flame retardant system should be applied to the unsaturated polyester resings.

  • PDF

Analysis of Thermal Characteristics of the Electrical Socket-Outlets by Overcurrent (과전류에 의한 전기콘센트의 열적특성 분석)

  • Kim, Doo Hyun;Kim, Sung Chul;Kim, Kyung Chun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.8-14
    • /
    • 2019
  • Many electrical socket-outlet fire accidents take place not only in homes but in the offices each year. The causes are mostly faulty constructions, managerial problems and carelessness. Construction and managerial flaws can be resolved by regular or special inspections, but carelessness is not solvable through inspections. Such carelessness can be related to the consumption capacity of electrical socket-outlets presently, the rated current of electrical socket-outlets is based on 16A. However, even at 16A, the heat generated in the insulator of an electrical socket-outlet varies due to such factors as part damage and environmental conditions of use. To explore this situation, the study conducted an experiment to analyze thermal relationship by applying 10A, 20A, and 30A currents. To secure reliability, the study employed thermal analysis simulation and compared the thermal relationship in the same current value. The experimental and simulation values were found to be similar and therefore, diverse current values were replaced with the simulation. At 30A, the temperature was found to rise to at least $169.9^{\circ}C$ which had worked as a sufficient amount of energy to bring the insulation aging of insulator.