• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.038 seconds

Improvement of Large Area Replicability Using DFSS in RTP System (DFSS 기법을 이용한 RTP 성형기의 대면적 전사성 향상)

  • Hong S.K.;Kim H.K.;Heo Y.M.;Kang J.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.571-572
    • /
    • 2006
  • RTP (rapid thermal pressing), one of micro-pattern replication techniques like hot embossing, is focused on achieving shorter cycle time. DFSS(Design for Six Sigma) has been applied in order to enhance the completeness of the development process for RTP system. According to DIDOV roadmap, we derived design concepts and subsequently decided the main performances, design factors, and components for RTP system. In the design process of RTP system using finite element analysis, it was realized that its structural characteristics affect large area replicability. Optimizing structural design factors, based on CAE, it was checked out that its large area replicability could be improved in a virtual test. Finally, we have a plan to validate the large area replicability of the developed RTP system, by performing micro-pattern replication tests with polymeric sheets.

  • PDF

Acoustic modeling of an air cleaner filter in the engine intake system (자동차 흡기계 공기 여과기 필터의 음향학적 모델)

  • Ih, Jeong-Guon;Kang, Jang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.114-117
    • /
    • 2006
  • The air filter in engine intake system has a function of filtrating the dirt in the scavenging air as well as attenuating the noise. The noise attenuation within the air cleaner filter, however, has been regarded as negligible by the field engineers. In this paper, for the analysis of the acoustical performance of air filter, an acoustical model was suggested and the characteristics of air filter system were investigated. Fibrous structure of the filter element was modeled as a micro-perforated panel using the flow resistivity and porosity. The pleated geometry of the filter element was modeled as two coupled ducts that have permeable walls, in which each duct area was assumed being constant. Using such simplified geometry, a mathematical model was developed for the sound propagation within a narrow duct system. Visco-thermal effect was considered in modeling the sound propagation through such tubes; the filter box was modeled as a rigid rectangular box. By combining two models, a four-pole transfer matrix was derived. For the validation purpose, transmission loss was measured for a plastic rectangular box containing an air filter. A noticeable effect of the air filter element was observed by including the filter into the box. Comparing the predicted and measured data, we found that the predicted TL agrees well with experimental results, in particular, in magnitude and frequency at TL troughs.

  • PDF

The Effect of Disaster Prevention of Industrial Field and Failure Detection of Very Small Components for IT (IT용 초소형부품의 불량검출과 산업현장의 재해방지 효과)

  • Park, Dea-Young;Jeong, Yang Guen;Choi, Sun Mi;Byun, Jea Young;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.1
    • /
    • pp.18-29
    • /
    • 2015
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The system was introduced into a real building and was examined by the field measurement. Judging from the measurements during three years(1999~2001), the state of the system operation was very stable through this period and it was clear that the system contributes to reduction of energy consumption for air-conditioning. Futhermore, a simulation model used the simple heat diffusion equation was developed to simulate its thermal characteristics and performances. The simulations resulted in air temperature in good agreement with the measurements. Also, from the result of numerical analysis, it is clear that the amount of heat supply by using this system is more than the amount of energy loss to the room above it. Therefore, it is concluded that this systems is very useful and the proposed numerical model can be used for the prediction of system thermal performance.

Performance Analysis of Kalina Cycle using Ammonia-Water Mixture as Working Fluid for Use of Low-Temperature Energy Source (저온 열원 활용을 위한 암모니아-물 혼합물을 작동유체로 하는 칼리나 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.1
    • /
    • pp.109-117
    • /
    • 2011
  • Since the thermal performance of cycles for use of low-temperature source is low if a pure working fluid is used, the cycles using ammonia-water binary mixture as a working fluid has attracted much attention over past two decades. Recently, several commercial power plants using Kalina cycles have been built and being operated successfully. In this work thermodynamic performance of Kalina cycles using ammonia-water mixture as a working fluid is investigated for the purpose of extracting maximum power from low-temperature energy source. Special attention is paid to the effect of system parameters such as concentration of ammonia and turbine inlet pressure on the characteristics of the system. Results show that the system performance is influenced sensitively by the ammonia concentration, and the role of the performance of heat exchangers is crucial.

Combustion Test of a Mach 5 Scramjet Engine Model (마하 5 스크램젯 엔진 모델의 연소 시험)

  • Yang, Inyoung;Lee, Yang-Ji;Kim, Young-Moon;Lee, Kyung-Jae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.3
    • /
    • pp.9-14
    • /
    • 2013
  • Combustion tests were conducted for a hydrogen-fueled Mach 5 scramjet engine model using a blow-down facility. No fuel and two fuel flow rate cases were tested for two different model configurations. Time history of the wall static pressures inside the model and their time-averaged spatial distribution were used for the analysis of the flow and combustion characteristics. For shorter model, supersonic combustion was occurred for both of the fuel flow rate cases. For longer model, supersonic combustion was occurred for less fuel case, whereas thermal choking and subsonic combustion were occurred for more fuel case. Intake started even for this subsonic combustion case.

A Survey of Direct Normal Insolation Resources in Korea (Focused on All days Analysis) (국내 법선면 직달일사량 자원조사 (전일 분석을 중심으로))

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.51-56
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67\;kWh/m^2/day$ of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91\;kWh/m^2/day$ and $2.23\;kWHm^2/day$, and for fall and winter their values were $2.78\;kWh/m^2/day$ and $2.77\;kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

Numerical Simulation for Urban Climate Assessment and Hazard (도시기후 평가와 방재를 위한 도시기상 수치모의)

  • O, Seong-Nam
    • Magazine of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.40-47
    • /
    • 2002
  • Since it is important to understand the bio-climatic change in Seoul for ecological city planning in the future, this paper gives an overview on bio-climate analysis of urban environments at Seoul. We analyzed its characteristics in recent years using the observations of 24 of Automatic Weather Station (AWS) by Korea Meteorological Administration (KMA). In urbanization, Seoul metropolitan area is densely populated and is concentrated with high buildings. This urban activity changes land covering, which modifies the local circulation of radiation, heat and moisture, precipitation and creating a specific climate. Urban climate is evidently manifested in the phenomena of the increase of the air temperature, called urban heat Island and in addition urban sqall line of heavy rain. Since a city has its different land cover and street structure, these form their own climate character such as climate comfort zone. The thermal fold in urban area such as the heat island is produced by the change of land use and the air pollution that provide the bio-climate change of urban eco-system. The urban wind flow is the most important climate element on dispersion of air pollution, thermal effects and heavy shower. Numerical modeling indicates that the bio-climatic transition of wind wake in urban area and the dispersion of the air pollution by the simulations of the wind variation depend on the urban land cover change. The winds are separately simulated on small and micro-scale at Seoul with two kinds of kinetic model, Witrak and MUKLIMO.

  • PDF

A Study on Air Flow Analysis for the Internal Space of the Dehumidifying Air-Conditioning System with A Membrane (분리막 제습공조시스템의 내부 유동 해석에 관한 연구)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.620-625
    • /
    • 2015
  • The summer climate is very hot and humid in Korea. Humidity is an important factor in determining thermal comfort. Recently, research on dehumidification device development has been attempted to save the energy required for operating the dehumidifier. Existing dehumidification systems have disadvantages such as wasting energy to drive the compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature. Therefore. they don't have to consume cooling energy. In this paper, the installation conditions for a membrane system were analyzed to improve the shape and optimum performance of the system. The results showed that the distance between elements was the critical system design factor, and that a distance of 20 mm was the optimal condition for the pressure drop and flow characteristics of the internal air flow.

ASSESSMENT of CORE BYPASS FLOW IN A PRISMATIC VERY HIGH TEMPERATURE REACTOR BY USING MULTI-BLOCK EXPERIMENT and CFD ANALYSIS (다중블록실험과 전산유체해석을 통한 블록형 초고온가스로의 노심우회유량 평가)

  • Yoon, S.J.;Lee, J.H.;Kim, M.H.;Park, G.C.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.95-103
    • /
    • 2011
  • In the block type VHTR core, there are inevitable gaps among core blocks for the installation and refueling of the fuel blocks. These gaps are called bypass gap and the bypass flow is defined as a coolant flows through the bypass gap. Distribution of core bypass flow varies according to the reactor operation since the graphite core blocks are deformed by the fast neutron irradiation and thermal expansion. Furthermore, the cross-flow through an interfacial gap between the stacked blocks causes flow mixing between the coolant holes and bypass gap, so that complicated flow distribution occurs in the core. Since the bypass flow affects core thermal margin and reactor efficiency, accurate prediction and evaluation of the core bypass flow are very important. In this regard, experimental and computational studies were carried out to evaluate the core bypass flow distribution. A multi-block experimental apparatus was constructed to measure flow and pressure distribution. Multi-block effect such as cross flow phenomenon was investigated in the experiment. The experimental data were used to validate a CFD model foranalysis of bypass flow characteristics in detail.

Numerical Analysis of Thermal and Flow Characteristics for an Optimum Design of Automotive Catalytic Converter (자동차용 촉매변환기의 최적설계를 위한 열 및 유동특성에 대한 수치적 연구)

  • Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.841-855
    • /
    • 1999
  • In the present work, the effect of a flow maldistribution on the thermal and conversion response of 8 monolith catalytic converter is Investigated. To achieve this goal, a combined chemical reaction and multi-dimensional fluid dynamic mathematical model has been developed. The present results show that flow uniformity within the monolith brick has 8 great impact on light-off performance of the catalytic converter. In the case of lower flow uniformity, large portions of the monolith remain cold due to locally concentrated high velocities and CO, HC are unconverted during warm-up period, which loads to retardation of light-off. It has been also found that the heat-up pattern of the monolith ill similar to the flow distribution profile, In the early stage of the reaction. It may be concluded that flow maldistribution can cause a significant retardation of the light-off and hence can eventually worsen tho conversion efficiency of automotive catalytic converter.