Browse > Article

A Survey of Direct Normal Insolation Resources in Korea (Focused on All days Analysis)  

Jo, Dok-Ki (Korea Institite of Energy Research)
Kang, Young-Heack (Korea Institite of Energy Research)
Publication Information
Journal of the Korean Solar Energy Society / v.28, no.1, 2008 , pp. 51-56 More about this Journal
Abstract
Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67\;kWh/m^2/day$ of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91\;kWh/m^2/day$ and $2.23\;kWHm^2/day$, and for fall and winter their values were $2.78\;kWh/m^2/day$ and $2.77\;kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.
Keywords
Direct Normal Insolation; Measurement Network;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Duffie John A. and Beckman William A., Solar Engineering of Thermal Process, John Wiley & Sons, Inc., 1991, pp. 3-145
2 Lunde P.J., Solar Thermal Engineering, John iley & Sons New York, 1980