• Title/Summary/Keyword: Thermal aging

Search Result 622, Processing Time 0.027 seconds

Characteristics of Insulation Aging in High Voltage Cables (고압케이블의 절연열화 특성)

  • Kim, Kyeong-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.88-88
    • /
    • 2010
  • High Voltage cross-linked polyethylene (XLPE) cables are widely used in a thermal power plant. These cables had been in service for 26 years. The insulation condition of six 6 kV XLPE cables was estimated by insulation diagnostic analyzer (IDA) with voltage amplifier. IDA was measured dissipation factor and capacitance of the whole cable as a function of frequency and voltage. This system measures in the frequency range from 0.1 to 10 Hz at each voltage level. Six XLPE cables are judged good condition, but three cables are analyzed at an aged condition.

  • PDF

Partial Discharge Tests for Traction Motor Using 1000 pF Couplers (1000 pF 커플러를 이용한 견인전동기 부분방전특성)

  • Ko, Byeong-Hun;Park, Hyun-June;Kwon, Sam-Young;Na, Hae-Kyung;Lee, Hyung-Woo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.214-218
    • /
    • 2007
  • With the development of high speed railway, traction motors play a critical role in the operation of railway vehicle. This paper describes the use of 1000 pF coupler as a on-line partial discharge (PD) measurement for the assessment of railway traction motor. The PD tests are performed with developed PD analyzer and the 5 model coils such as thermal, electrical, mechanical and environmental aging respectively at various AC voltages. On-line PD tests using 1000 pF couplers show that PD patterns can be detected successfully at 2.3 kV.

  • PDF

A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock (철도차량 견인전동기의 가속열화수명평가 기술현황)

  • Wang, Jong-Bae;Kim, Ki-Jun;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

A Study on the Electrical and Mechanical Properties of a Epoxy Powder for Compact Bus Duct (콤팩트 부스덕트용 에폭시분체도료의 전기적.기계적 특성연구)

  • Kim, Sang-Hyun;Choi, Jin-Wook;Kim, Dong-Wook;Kim, Hyun-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.210-217
    • /
    • 2009
  • Insulated methods of compact bus duct has been applied a way of coating Epoxy powder. The problem which is caused by degradation during operation is very important in severe environment. Therefore, this study compared and verified many kind of properties ; electrical breakdown by thermal and water aging, v-t characteristic, arc discharge, mechanical properties, bending test and cross cut. Sample D was stable before the $T_g$ to be about $7{\sim}10 %$ decrease in the breakdown test according to temperature change. In case of V-t and arc discharge, it had been kept up suitable characteristic. Also, in case of electrical and mechanical characteristic, both sample D and A have excellent capacity.

A VLF Breakdown Strength Test of The XLPE Cable on Thermal Aging (열 열화에 따른 XLPE의 VLF 절연파괴 특성)

  • LEE, Seung-Won;KIM, Su-Hwan;KIM, Yong-Hyun;LIM, Jang-Seob;LEE, Kun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1215-1215
    • /
    • 2015
  • 본 연구에서는 상용 XLPE 절연체에 ES(한전)의 장기과통전 시험 기준을 참고하여, 가속 열 열화 하였고, 열화 전/후의 절연특성을 비교하기 위하여 VLF(0.1Hz) 내전압 파괴시험을 수행하였다. 또한, 그 결과를 Weibull plot하여 절연특성을 통계적으로 비교 및 분석하였다.

  • PDF

Equipment Qualification of a Safety-related Large Induction Motor for Nuclear Power Plants (원자력발전소 안전등급 대형유도전동기의 기기검증)

  • Ko, W.S.;Kim, J.;Hur, I.G.;Choi, B.W.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.498-503
    • /
    • 2000
  • A safety-related equipment for use in Nuclear Power Plant should be needed an Equipment Qualification. This paper presents the approach, methods, philosophies, and procedures for qualifying the large squirrel-cage induction electric pump motors for use in ULCHIN 5&6 Nuclear Power Plants. In this paper, the method of qualification is a combination of type test and analysis method, which is composed of Radiation exposure test, Seismic simulation test, Thermal aging analysis for non-metallic materials and Seismic analysis. It is found that the motor performs its safety function with no failure mechanism under postulated service conditions.

  • PDF

Microstructure Analysis of Large Turbine Generator Stator Insulations (대형 터빈발전기 고정자 권선의 미세구조 분석)

  • Kim, Hee-Dong;Ju, Young-Ho;Song, Seong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1452-1454
    • /
    • 2002
  • Large turbine generator(rated 22kV) has failed in the stator winding area during normal operation. The capacitance and tan${\delta}$ were measured by Schering bridge in the zone 1, 2 and zone 3-6 stator windings. The capacitance and tan${\delta}$ in the zone 1, 2 of stator winding were higher than those of zone 3-6 in the stator winding. Experiments on microstructure property were conducted in the zone 1, 2 and zone 3-6 insulations, which were drawn out from stator windings of the large turbine generator. Microstructure analysis was characterized using scanning electron microscope(SEM). SEM results indicated that several isolated delaminations occurred at the interface of mica/epoxy insulations. Both thermal and mechanical aging cause the delamination.

  • PDF

A study on the On-Line Diagnostic Technique of High Voltage Induction Motor by partial discharge Pattern Analysis (부분방전 패턴분석에 의한 고압유도전동기 무정전 진단기법 연구)

  • Jung, Young-Ill;Lee, Eun-Suk;Kim, Duck-Keun;Lim, Yung-Bae;Kim, Jong-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1685-1687
    • /
    • 2002
  • High voltage(H.V.) induction motors have been applied to various industrial applications. But aging and failure of induction motors are initiated by electrical, mechanical, thermal and chemical processes during manufacturing or in-service. These detects reduce locally the dielectric strength of the insulation. At such defects partial discharges can occur, which cause further degradation of the insulation and reduce the life time of the H.V induction motors. Consequently in this paper, we studied the partial discharge pattern analysis of H.V. induction motor for on-site applications.

  • PDF

Inverstigation of Thermal Aging Effect of Battery for Stand-Alone Type Wind Power Generation system (독립형 풍력발전 시스템용 축전지 운전 특성 및 노화평가 시험)

  • Kim, Hi-Jung;Ju, Chan-Hong;Lee, Jun-Hyun;Song, Seung-Ho;Shinn, Chan;Kim, Dong-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.129-132
    • /
    • 2002
  • 대체 에너지(태양광, 풍력등)의 전력저장 시스템으로 널리 사용되는 겔형(Gel Type) 밀폐형 연(鉛)축전지의 노화 특성 평가 및 충전회로에 관하여 연구하였다. 납 합금을 이용한 기판 주조 기술과 전해액(Gel) 배합기술이 축전기 성능과 수명을 좌우하며 또한 배터리 충전 시스템에 따른 온도 상승이 치명적인 영향을 미치게 된다. 따라서 본 연구에서는 적외선 열화상 장치를 이용한 내부 열원 추적에 의해 노화정도를 측정하며 축전지 수명시험을 통해 입수한 데이터와 비교 평가하고자 한다. 현재 실험실 충방전 수명시험을 마치고 (주)코윈텍이 부안 해창 공원에 설치한 30kW급 풍력발전 시스템에 적용하여 Field Test를 시험중이다.

  • PDF

Effect of Moisture Absorption on Dielectric Breakdown Phenomena of DGEBA/MDA/SN/Natural Zeolite System (DGEBA/MDA/SN/천연 제올라이트계의 절연파괴현상에 미쳐는 흡습의 영향)

  • Kim, You-Jeong;Lee, Hong-Ki;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.994-996
    • /
    • 1999
  • Hygrothermal aging at the elevated temperature induces the long-term degradation of the epoxy resin. We investigated the effects of hydrothermal stress on the dielectric breakdown phenomena of epoxy composite filled with natural zeolite. The cured specimens absorbed the moisture in the autoclave at $120^{\circ}C$. $T_g$ of the deteriorated composite by moisture absorption decreased. The dielectric breakdown strength decreased with the moisture absorption cycle. It was concluded that the thermal stress and the high water-vapour-pressure deteriorated the natural zeolite filled epoxy resin system, consequently and the tree growth rate increased.

  • PDF