• 제목/요약/키워드: Thermal Protection Material

검색결과 121건 처리시간 0.024초

초다공성 에어로젤 함유 섬유상 복합체를 이용한 신발 안창소재에 관한 연구 (Study on Ultra Porous Aerogel/fiber Composite for Shoe Insole)

  • 오경화;박순자
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.701-710
    • /
    • 2009
  • This study was conducted to develop excellent insole with good thermal insulation using new materials. We investigated that aerogel/fiber composite can be used as padding materials of shoes by comparing surface shape, moisture regain, water vapor permeability, thermal insulation and compression rate of insole materials tried with nonwoven fabric padding materials and insole sold in market. The results are as follows. Surface shapes were shown that the most appropriate material for sealing aerogel/fiber composite was high density fabric as per size of particle of aerogel. Moisture regain of aerogel/fabric composite was better than nonwoven fabric padding samples. However, when compared to insole sold in market, its moisture regain was worse than those of insole merchandises. Water vapor permeability was higher in material padded with nonwoven fabric than materials padded with aerogel/fiber composite in all three kinds of sealing fabrics. Thermal conductivity of aerogel/fabric composite was lower than nonwoven fabric material regardless of sealing fabrics. Thermal insulation of aerogel/fiber composite was higher than padding material of nonwoven fabric regardless of sealing fabrics. Compression rate of nonwoven (SP1) was higher than that of aerogel/fiber composite (SP2). Compressive elastic recovery rate of SP1 was also higher than that of SP2, which its compression rate and compressive elastic recovery rate were both poor. As the above result, ultra porous aerogel/fiber composite were proved to be material of good thermal insulation with lower thermal conductivity and also compression rate was proved to be low. Therefore, we can say that aerogel/fiber composite have high possibility to be used as insole materials for cold winter shoes requiring good thermal insulation protection.

경년열화에 의한 소형 환풍기의 전기화재에 관한 연구 (A Study on Electrical Fire of Small Ventilators due to Aged Degradation)

  • 임종룡;이성일
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.22-26
    • /
    • 2016
  • "Always-on" small ventilators are likely to experience thermal decomposition of insulating material due to thermal, electrical, mechanical and environmental influences, and lose insulating properties by the process of oxidation and physiochemical reaction. This increases the risk of electrical fire because of layer short, short circuit, overload and Plastics are usually used to make ventilator and ventilator enclosures since they make less noise and are cheaper. Although more preferred than iron, plastic, a combustible material, has a higher risk of fire. In this study, several experiments were carried out to find out how RCD(Residual Current Protective Device) and Thermal fuses, which are electric motor protection devices, work and what needs to be done to reduce the risk of fire.

CHARACTERISTICS OF FIRE PROTECTIVE COATING THE TERNARY SOLUBLE SILICATE

  • Lee, Nae-Woo;Choi, Jae-Wook;Kim, Jeong-Hun
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.120-129
    • /
    • 1997
  • The fire protective coating can reduce certain damages in case of fire, also conserve energy by thermal insulation and prevent corrosion and errosion in normal daily life by means of blocking thermal transfer, that were generally made of organic, inorganic and metallic materials as adiabatic coating. In case of inorganic material such as soluble silicate, it produces less toxic substances which are exposed to Ore, and have a plenty of raw material. Also inorganic thermal insulator is good in heat resistance. To develope such a excellent inorganic thermal insulator, the study of fire protective coating using the alkali silicate is necessary The principle of intumescence for alkali silicate is from rapid evolution of water in the coating material, the quantity of water in it is of course influenced on the degree of intumescence. The phenomenon of intumescence in ternary silicate is increased as the radius of ion is bigger, and this is caused by evolution of so many kinds of water. The individual degree of intumescence is ordered like this ; $K^+$ > $Na^+$ > $Li^+$ . The best protection effect is similarity found to intumescence of ternary silicate. The result of X-ray diffraction analysis indicates that $KHSi_2O_5$ is an important ingredient in K-silicate.

  • PDF

시스템 LED 조명의 전기적·열적 안전성 확보 방안에 대한 연구 (A Study on the Electrical and Thermal Safety of System LED Lighting)

  • 김영우;김충혁;최운식
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.418-426
    • /
    • 2020
  • This study tested the electrical, structural, and thermal safety of LED lighting products, available on the market. Five recessed LED systems, 20 W each, and five fixed LED systems, 25 W each, were selected. Dielectric strength tests, live part electric shock protection tests, and thermal tests were conducted on the LEDs. These were key tests for user safety, according to the specification of the safety criteria for electric products, KC 60598-1, South Korea. In addition, the wiring temperature of UL1007, 60227 IEC 08, and UTP cables, was measured. The results of the study gave an in-depth examination of the safety of LED lighting systems for users.

한국 소방대원 방수피복의 소재특성에 관한 비교 연구 (A Study on the Textile for Protective Clothing of Fire Fighters)

  • 정정숙;이연순
    • 대한가정학회지
    • /
    • 제40권5호
    • /
    • pp.15-24
    • /
    • 2002
  • The following research conclusions were made, relative to the experiments of the textiles of fire fighters Protective Clothing. 1. When the body protection efficiency such as the thickness, the strength and heat resistance are considered, Nomex(N) is tuned out the best outer shelf, Gore-tex(KG) the best moisture barrier, and Wool-felt(WC) the best thermal barrier. 2. In the hygienic and sanitary efficiency also, N is turned out the best outer shelf, KG the best moisture barrier, and WC the best thermal barrier in its degree of water resistance, water vapour permeability, and air permeability. 3. In the washing and maintenance efficiency, too. N is turned out the best outer shell, KG the best moisture barrier, and WC the best thermal barrier, being considered the material's rate of contraction, the changing rate of frame resistance, water resistance, and water vapour permeability. 4. When considered the frame resistance against the reflection tape and reflection efficiency, O is the best material for it marks the highest score in the frame resistance and reflective effect.

상변화물질을 이용한 열방어체계의 수치해석 연구 (A numerical analysis of the PCM applied Thermal Protection System)

  • 오창묵;유영준;이형주;민성기
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.622-627
    • /
    • 2010
  • 본 논문은 내외부에 열원이 있는 시스템에 상변화물질(PCM, Phase Change Material)을 적용한 경우를 수치해석으로 분석한 것으로 컨넥터가 없는 경우와 있는 경우에 대하여 분석한 것이다. 각각의 경우에 $T_{max}$ 열원만 있을 경우와 $T_{max}$$710W/m^2$ 열원이 동시에 있을 경우가 고려되었다. 연구 결과 벽면에서의 열전달, 시간에 따른 PCM 온도변화 그리고 내부온도의 변화를 정리하였으며 그 결과 시스템의 구성품과 열전달 방향 및 열원의 종류에 따라 PCM의 잠열 시간이 달라진다는 점을 알 수 있었다.

  • PDF

Al-Zn-Zr 열용사 코팅의 캐비테이션 거동에 대한 실링의 효과 (Effects of sealing on cavitation behavior of Al-Zn-Zr thermal spray coating and sealing)

  • 김성종;한민수;이승준
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 추계학술대회 초록집
    • /
    • pp.245-246
    • /
    • 2009
  • The large and high-speed vessels have been greatly advanced, but ship materials have been caused the problem such as corrosion, cavitation and erosion. Cavitation can produce material damage such as pumps, turbines, valves and ship propellers etc. To solve these problems, the cavitation and electrochemical characteristics for thermal spray coating and the sealing are executed to obtain the excellent corrosion protection characteristics in sea water environment.

  • PDF

삭마 및 열분해 반응을 고려한 고체 추진기관의 열해석 (Thermal decomposition and ablation analysis of solid rocket propulsion)

  • 김연철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.113-122
    • /
    • 2010
  • 고체추진기관의 연소 환경에서 복잡한 형상을 갖는 내열 복합재료의 온도, 밀도분포 및 삭마두께를 예측할 수 있는 방법을 개발하였다. 복합재료의 내부 열반응은 Arrhenius 모델을 이용하였으며, 표면 삭마반응은 Zvyagin 이론을 사용하였다. 표면 삭마에 의한 경계조건 및 격자 이동은 상용해석 코드에서 활용되는 Rezoning-remeshing 기법을 사용하였다. 형상이 복잡한 부품으로 이루어진 2차원 축대칭 노즐 조립체에 적용된 방법은 향후 3차원 FEM 열구조 해석에 활용을 목표로 발전될 것이다.

  • PDF

Phase Change Material (PCM) 소재 적용 소방보호복의 화상발생 억제효과에 관한 연구 (Inhibitory Effect of adding Phase Change Material (PCM) to Fire Fighter Protective Clothing on Burn Injuries)

  • 이준경
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.16-22
    • /
    • 2016
  • 소방공무원의 화상방지를 위해 소방보호복의 개발이 이루어지고 있으나, 보호 성능을 높이기 위해서 소재의 두께가 증가하고, 그럼으로 경량화 달성이 어려워지는 단점이 존재한다. 이를 극복하기 위한 여러 가지 방법 중 Phase Change Material(PCM, 상변화 물질)을 적용한 섬유를 소방보호복 안감에 적용하는 연구가 진행되고 있다. 기존 연구의 경우, 고온노출시 PCM 적용 섬유의 온도 특성에 대한 연구가 일부 있었으나, 화상 발생과의 직접적인 연관성을 살펴볼 수가 없다는 큰 단점이 존재한다. 본 연구에서는 짧은 시간 고열유속 상태의 돌발화염조건에 대해 현재 사용되고 있는 소방보호복 안감에 대한 PCM 적용 여부에 따라 2도 화상 발생 억제 효과를 수치계산을 통해 살펴보았다. 피부의 화상 해석을 위해 생체 열전달 방정식(Bio-heat transfer)을 이용하여 지배방정식을 유도하였으며, 유한차분법(Finite Difference Method)을 활용하여 화상에 대한 예측을 수행하는 수치해석 접근법을 사용하였다. 시간에 따른 온도 및 손상함수 결과 분석을 통해 PCM 소재의 열흡수가 열전달을 지연시키는 효과가 큼을 확인할 수 있었고, 그에 의해 화상발생을 방지하는 매우 유효한 방법임을 확인할 수 있었다.

공력가열 시험설비 설계

  • 옥호남;김인선;라승호;김성룡;조광래
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.155-169
    • /
    • 2004
  • 발사체나 재돌입 비행체는 대기 중을 높은 Mach 수로 비행함으로써 그 표면이 공력가열 현상에 의한 초고온 환경에 노출되게 된다. 이러한 공력가열로부터 발사체 자체나 탑재체를 보호하기 위해서는 물체 표면에 가해지는 열적 부하(Thermal Load)를 정확히 예측하고 필요한 곳에는 적절한 단열 처리를 해 주어야만 한다. 그러나 탑재체의 중량을 최대한 늘리기 위해서는 지나친 단열재의 추가를 막을 수 있도록 엄밀한 열 해석 및 시험이 수행 되어야 할 것이며, 최종적으로 공력가열 시험에 의해서 필요한 단열재의 양이 결정된다. 본 연구에서는 KSR(Korea Sounding Rocket) 시리즈의 개발을 위해 사용되어 왔던 공력가열 시험설비(ATSF, Aerodynamic Thermal Simulation Facility)를 KSLV 시리즈의 개발에 적합하도록 사양 향상(Upgrade) 시키기 위한 설계를 위해 고려해야할 사항이 무엇인지 살펴보았다. 먼저 설비의 필요성 및 그 한계에 대하여 고찰하였으며, KSLV 개발을 위해서는 어떤 기능을 갖추어야 할지를 고려하였다. 마지막으로 필요한 장비의 사양을 대략적으로 제안하였으며, 이는 앞으로 수행될 상세 설계 및 제작/설치의 밑바탕이 될 것이다.

  • PDF