• 제목/요약/키워드: Thermal Gravimetric Analysis

검색결과 154건 처리시간 0.02초

Morphological, Thermal and Dynamic Mechanical Properties of Polyurethane Product with Various Contents of Acrylic Polyol (Acrylic Polyol 함량을 달리한 폴리우레탄 제품의 형태학적 열적 및 동적·기계적 성질)

  • Kim, Tae Sung;Park, Chan Young
    • Elastomers and Composites
    • /
    • 제48권4호
    • /
    • pp.276-281
    • /
    • 2013
  • Polyester type polyurethane foam modified with acrylic polyol was prepared by quasi prepolymer method. Thermal and dynamic mechanical properties of polyurethane foam were analysed by thermal gravimetric analysis(TGA) and dynamic mechanical analysis(DMA). Also, glass transition temperature was measured by differential scanning calorimeter(DSC). As acrylic polyol contents were increased, thermal stability measured by TGA was slightly decreased. Storage modulus was increased and tan delta was decreased with increasing of acrylic polyol contents.

Removal of Heavy Metals(Pb, Cr) Using Waste Eggshell

  • Park, Heung-Jai;Bong, Sang-Hun;Jeong, Seong-Ug
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.386-393
    • /
    • 2005
  • The calcination characteristic of waste eggshell were examined by thermal gravimetric analysis (TGA), qualitative and quantitative analysis by X-ray fluorescence, and microstructural analysis by scanning electronic microscopy(SEM). The calcined sample was lager grain and pore size.

  • PDF

The Thermal Stability Analysis of Fumes and Mists During the Drying Process of a PCB (PCB 건조공정의 흄과 미스트에 대한 열안정성 분석)

  • Chu, Chang Yeop;Lee, Jung Suk;Baek, Jong Bae
    • Journal of the Korean Society of Safety
    • /
    • 제34권4호
    • /
    • pp.32-40
    • /
    • 2019
  • During the manufacturing process of a printed circuit board(PCB), fumes and mists are generated as the ink dries on the PCB surface. The generated fumes and mists are deposited in the dryer wall and the exhaust duct. Deposited fumes and mists may present a fire hazard if the dryer temperature control system fails. In this study, the thermal stability of the fumes and mists deposited in the dryer and ducts has been analyzed by experimental methods such as thermo gravimetric analysis (TGA), differential scanning calorimetry (DSC), auto ignition temperature (AIT), and multiple mode calorimetry(MMC). According to the experimental analyses, experimental samples are likely to generate gas at the temperature ($180{\sim}240^{\circ}C$) that deviates from the normal operating temperature ($150{\sim}156^{\circ}C$). It has been shown that the thermal stability is degraded when the temperature is deviated from the normal operating temperature. In the end, engineering and management safety measures of accidental prevention have been suggested.

An Experimental Study on Measurement of Chemical Kinetic Parameters of a Liquid Fuel with Various Components (혼합 액체 연료의 화학반응 인자 계측에 관한 실험적 연구)

  • Choi, Hyo-Hyun;Lim, Jun-Seok;Kim, Chul-Jin;Sohn, Chae-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • 제16권3호
    • /
    • pp.21-26
    • /
    • 2011
  • Thermal analyses are conducted to measure chemical kinetic parameters of an unknown liquid fuel with various components. Thermal Analyses are divided into two different methods such as TGA(Thermo-Gravimetric Analysis) and DSC(Differential Scanning Calorimety). Non-isothermal experimental results are analyzed by adopting TGA and they are filtered by Freeman-Carroll method. As a results of the analysis, chemical parameters of the activation temperature and the reaction order are measured to be 6128.2 K and 1.4, respectively. Furthermore, the chemical kinetic parameters are obtained by a variety of mathematical processing methods. It has been found that they show a little difference depending on the processing method.

Measurement of Carbonation Depth of Concrete in Old Buildings and Experimental Evaluation of Carbonation Degree and CO2 Absorption Using Differential Thermal Gravimetric Analysis, Part2 (노후 건축물의 콘크리트 탄산화 깊이 측정과 시차열 중량분석을 통한 탄산화도 및 CO2 흡수량 실험적 평가, Part2)

  • Lee, Sang-Hyun;Ki, Jun-Do;Cho, Hong-Bum;Park, Chang-Gun;Kim, Young-Sun;Moon, Hyung-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.317-318
    • /
    • 2023
  • This study is part of the carbonation degree DB accumulation through quantitative analysis of carbonation depth, Ca(OH)2 and CO2 according to the type of finish and years of use of old concrete structures in order to predict the amount of CO2 that can be absorbed through carbonation of concrete. To this end, the depth of carbonation of the concrete core specimen is measured using an indicator, and the dry amount of water combined with CO2 in the sample is measured using a differential thermal gravimetric analyzer for samples in the carbonation area and non-carbonated area classified by the indicator, and the absorption compared to the weight of the sample. The amount of absorbed CO2 was calculated. In addition, the degree of carbonation was calculated through quantitative comparison of Ca(OH)2 in the carbonation section and non-carbonation section. In the future, we will continue to add the survey and analysis data of dismantled structures and use them as basic data for estimating the amount of carbon dioxide that can be absorbed according to the exposure conditions and years of use by concrete mix.

  • PDF

Synthesis and Characterization of Non-halogen Type Phosphorus-Based Flame Retardants (비할로겐형 phosphate계 난연제의 합성 및 특성결정)

  • Han, Young Gyun;Min, Seong Kee;Park, Chan Young
    • Elastomers and Composites
    • /
    • 제49권4호
    • /
    • pp.313-322
    • /
    • 2014
  • Among many types of flame retardants, the most available halogen-containing flame retardants were put under environmental restrictions in their use, so non-halogen type phosphorus-based flame retardants have come into the spotlight. When added to resins, flame retardants commonly bring about thermal degradation and decrease in mechanical properties of resins. Studies of new flame retardants were carried out in an attempt to minimize degradation of physical properties and require enough flame retardancy. In this study, three types of non-halogen phosphorus-based flame retardants were synthesized with diaryl alkyl phosphate esters, aromatic phosphate esters and phosphonium nitron flame retardants, which were then identified for the synthesis and thermal properties by gas chromatography (GC), IR and thermal gravimetric analysis (TGA).

Effects of GN Contents on Thermal Decomposition of Epoxy Resin System (GN 함량에 따른 에폭시 수지계의 열분해 특성)

  • 안현수;심미자;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.389-392
    • /
    • 1997
  • Glutaronitrile(GN) was introduced to diglycidyl ether of bisphenol A(DGEBA)/ 4,4'-methylene dianiline(MDA) system to improve toughness. Effects of GN contents on thermal decomposition of epoxy resin system were investigated. To study the characteristics of thermal decomposition, thermo-gravimetric analysis(TGA) and Kissinger equation were used. Thermal degradation temperatures were about 365$^{\circ}C$ regardless of GN contents. Activation energies of thermal decomposition in epoxy resin system were almost constant below 10 phr and decreased above 15 phr.

  • PDF

An Experimental Study on Measurement of the Reaction Order of a Liquid Fuel with Various Components (혼합 액체연료의 화학반응차수 계측에 관한 실험적 연구)

  • Choi, Hyo-Hyun;Lim, Jun-Seok;Kim, Chul-Jin;Sohn, Chae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.421-424
    • /
    • 2011
  • Thermal Analyses are conducted to measure various factors of a liquid fuel required for numerical analysis. Thermal Analyses are divided into two different methods of TGA (Thermo Gravimetric Analysis) and DSC (Differential Scanning Calorimetry). Non-isothermal experimental results are analyzed using by TGA. The results are filtered by a Freeman Carroll method. At the same time, chemical parameters of unknown liquid fuel, activation temperature and reaction order are measured to 6128.2 K and 1.4, respectively. Furthermore, the parameters can be obtained by various mathematical methods. It is found that tha parameters depend on the processing method.

  • PDF

Measurement of carbonation depth of concrete in old buildings and experimental evaluation of carbonation degree and CO2 absorption using differential thermal gravimetric analysis (노후 건축물의 콘크리트 탄산화 깊이 측정과 시차열 중량분석을 통한 탄산화도 및 CO2 흡수량 실험적 평가)

  • Lee, Sang-Hyun;Ki, Jun-Do;Cho, Hong-Bum;Park, Chang-Gun;Kim, Young-Sun;Moon, Hyung-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2022
  • Based on the carbonation depth measurement by the indicator for concrete collected from old structures and the quantitative analysis of Ca(OH)2 and CO2 in the carbonation section before and after the carbonation depth and in the non-carbonation section, the absorbable CO2 amount and carbonation degree measurement result is as follows 1) The carbonation depth of the 40-year-old reinforced concrete structure was measured to be about 22 mm. (basement interior wall, marble finish, strength 30MPa) 2) The amount of CO2 absorbed by the concrete was about 4.3% of the sample weight, and the carbonation degree was estimated to be about 53%.

  • PDF

Conversion Characteristics of MSW at Various Pyrolytic and Oxidative Conditions (열분해 및 산화조건에서 MSW의 물질전환특성 연구)

  • Byen, Kyong-Hee;Lee, Yong-Jin;Yoon, Kyoon-Duk;Dong, Jong-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제22권11호
    • /
    • pp.1955-1968
    • /
    • 2000
  • Thermal gravimetric change characteristics and gas phase product - CO, NO, $NO_2$, VOCs - generated in the process of pyrolysis and oxidation. were investigated with variation of process parameters including furnace reactor temperature both in pyrolytic and oxidative conditions. For the thermal gravimetric change characteristics. paper and wood were mainly decomposed at lower temperatures and they had similar thermal gravimetric change trend due to their similar compositions; plastics were mainly decomposed at higher temperatures; in the case of textile. natural compounds were decomposed at lower temperatures and synthetic compounds at relatively higher temperatures; food was decomposed in the wide range of temperatures possibly due to their different kinds of components. For the analysis results of gas phase product. the concentrations of NO, $NO_2$ were detected at higher level at the oxidative conditions than at the pyrolytic conditions except that of CO, which is due to complete combustion with sufficient oxygen at the oxidative condition; food gave off CO, NO, $NO_2$ more than the other wastes. VOCs were emitted more at the pyrolytic conditions than at the oxidative conditions.