• Title/Summary/Keyword: Thermal Fatigue

Search Result 572, Processing Time 0.025 seconds

A Study on Wear Sensations of Tecel Fabrics in Hot Environments (서열환경 하에서의 텐셀소재 의복의 착용감 연구)

  • 권오경;송민규;이창미
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.3
    • /
    • pp.149-161
    • /
    • 2000
  • The purpose of the study was to examine the effect of Tencel fabrics on physiological reactions of a human body and thermal comfort under the hot environment. The 3 females subjects in their twenties were selected and a wear sensation test of the subjects was performed with four experimental ensembles made of cotton and Tencel fabrics for the study in the hot environment(3$0^{\circ}C$, 70%RH). The resets of the test were summarized as follows: For the mean skin temperature, Tencel garments showed about 0.2$^{\circ}C$-0.4$^{\circ}C$ lower than that of the cotton garment. The temperature of the rectal was 0.2$^{\circ}C$-0.4$^{\circ}C$ lower for Tencel garments than that for the colon garment. In the form of ensembles, the order of rectal temperature of the subjects for both Tencel and cotton ensembles was 1>IV>III>II. In the body weight loss according to garment materials, Tencel had a lower and more uniform than the cotton Thus, it could concluded that if the perspiration took into account, garments made of Tencel can be more ideal than that of the cotton. The heart rate and oxygen consumption appeared to be proportional to each other. For the heart rate, ensemble TI and TII of Tencel were much lower than ensemble CI and CII. For whole enembles except for TIV, Tencel ensembles showed relatively better thermal sensation and comfort sensation than the cotton ensembles. In the fatigue sensation, the reactions of the subjects were “slightly fatigue” and “fatigue” for the cotton, but “neutral” and “slightly fatigue” for Tencel.

  • PDF

A Study on the Effects of PMV Thermal Environment and Illumination on Visual Performance (PMV 온열 환경과 조도가 시작업 성능에 미치는 영향에 대한 연구)

  • Kim, Hyung-Sun;Kim, Hyoung-Tae;Kim, Hyoung-Sik;Kuwak, Won-Tack;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.55-62
    • /
    • 2014
  • In this study, a questionnaire was developed to assess error search and correction tasks, and an analysis was performed on the accuracy of the tasks and the time required for their completion in order to identify the effects of LED light source illumination on visual performance according to changes in a predicted mean vote(PMV) thermal environment. In addition, a subjective evaluation was performed by conducting a survey on the level of visual fatigue experienced during the tasks. In the experiment, four types of PMV thermal environments were established according to PMV values in the temperature range of $(17{\pm}1-29{\pm}1)^{\circ}C$ and the humidity range of $(50{\pm}5-60{\pm}5)%$, and the LED light source illumination was divided into three types: 400lx, 700lx, and 1000lx. The experimental results confirmed that the accuracy of the error search(LED p value=0.058, PMV*LED p value=0.083) and correction tasks and the time required(LED p value=0.004, PMV p value=0.000) for their completion were affected by changes in both the PMV thermal environment and the LED light source illumination, whereas a significant difference in visual fatigue was observed only in the PMV thermal environment(p value=0.003).

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.

Fatigue Crack Growth Behavior of a Magnesium-Based Composite (마그네슘 금속복합재의 피로균열거동해석)

  • Kim, Doo Hwan;Park, Yong Gul;Kim, Sung Hoon;Han, Suk Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.515-521
    • /
    • 1997
  • The effects of heat treatment and fiber orientation on tensile strength and fatigue behavior were studied in a continuously reinforced. magnesium-based composite Following an earlier TEM investigation, specimens were thermally aged to modified the interfacial zone between the alumina fibers and the magnesium alloy matrix. From the tensile experimental results, the ultimate tensile strength of the aged specimens were lower than that of the as-fabricated due to weak fiber-matrix interfacial strength with chemical reaction during the thermal processing. The fatigue crack growth experiments were conducted with specimens having the fiber orientation normal to the crack growth direction (longitudinal) and also specimens with the fibers oriented parallel to the crack growth direction(transverse). A comparison of the fatigue crack growth behavior indicates that aged longitudinal specimens are more resistant to fatigue crack growth the as-fabricated longitudinal specimens. Conversely, as-fabricated transverse specimens are more resistant to fatigue crack growth than aged transverse specimens.

  • PDF

Effects of Temperature and Stress Ratio on Low-Cycle Fatigue Crack Growth of G91 Steel (G91강 저주파 피로균열 성장에 미치는 온도와 응력비의 영향)

  • Kim, Jong Bum;Hwang, Soo-Kyung;Kim, Bum Joon;Lee, Jong Hoon;Park, Chang Gyu;Lee, Hyeong Yeon;Kim, Moon Ki;Lim, Byeong Soo
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.4
    • /
    • pp.271-279
    • /
    • 2012
  • 9-12% Cr steels have been used in thermal power plants which repeat start and stop operations. Major factors of fatigue life are temperature, frequency, stress ratio, holding time, microstructure, and environment. Normally, fatigue life decreases at high temperature, low frequency, high stress ratio, and long holding time conditions. A Mod.9Cr-1Mo steel, called G91, was developed at ORNL (Oak Ridge National Laboratory, USA) and was adopted as a high-temperature structural material in the ASME Code in 2004. However, its low-cycle fatigue and fatigue crack growth characteristics have been rarely studied. In this work, we have investigated the low-cycle fatigue crack growth behaviors of G91 steel under various test conditions in terms of temperature and stress ratio. As temperature and stress ratio increase, the crack growth rate becomes faster and striation distance also increases. On the other hand, the number of branch cracks decreases.

Thermal Stress Analysis for a Ventilated Disk Brake of Railway Vehicles (철도 차량용 제동디스크의 열응력 해석)

  • Lee Y.M.;Park J.S.;Seok C.S.;Lee C.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1617-1621
    • /
    • 2005
  • In this study, as a basic research to improve braking efficiency of a ventilated disk brake, we carried out a thermal stress analysis. From analysis result, we knew that a maximum mechanical stress by braking pressure and friction force is applicable to 5 percent of yield strength and has no effect on a fatigue life's decrease for brake disk material. While, a maximum thermal stress by frictonal heat is applicable to 43 percent of yield strength and locates on a friction surface. So, we have found that a thermal stress is the primary factor of crack initiation on a friction surface of disk brake

  • PDF

Numerical Analysis of Thermal Stratification due to Turbulence Penetration into Leaking Flow in a T Branch (사각 T분기관내 누설유동의 난류침투에 의한 열성층 발생에 관한 수시해석적 연구)

  • Hong, Seok-Woo;Choi, Young-Don;Park, Min-Su;Seo, Jung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.729-734
    • /
    • 2001
  • Thermal stratification due to turbulence penetration and in-leakage of valve cause the large thermal stress, which lead to fatigue crack of the piping system of nuclear power plant. So it is needed that numerical and experimental study for the phenomenon is conducted because there have not yet been sufficient study for the relationship between turbulence penetration and thermal stratification. Therefore numerical analysis is done here and respected to give a fundamental method of the approach to the phenomenon.

  • PDF

3-Dimensional Numerical Analysis for Thermal Stratification in Surgeline in Nuclear Power Plant (원전 밀림관 열성층의 3 차원 수치해석)

  • Kim, Young-Jong;Kim, Maan-Won;Ko, Eun-Mi
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.729-734
    • /
    • 2008
  • A thermal stratification may occur in the horizontal parts of the surge line during operating transients of the pressurizer, which produces relatively high fatigue usage factor. Heat-up transient is the most severe case among the transient conditions. In this study, to study the relationship between the magnitude of thermal stratification and the length of vertical part of the surge line, some parametric fluid-structure interaction (FSI) analyses with different length variables of the vertical part of the surge line were performed for plant heat-up transient condition by using 3-dimensional numerical analysis. The conservativeness of the traditional finite element model for thermal stratification analysis based on the conservative assumption in the surge line was also discussed by comparison of the results of 3-dimensional transient FSI analysis of this study. Stresses calculated with 3-dimensional transient model were considerably reduced comparing with the traditional analysis.

  • PDF

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Coolant Leaking in a T-Branch of Square Cross-Section

  • Choi, Young-Don;Hong, Seok-Woo;Park, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. Standard k-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Leaking Flow in a T-Branch of Square Cross-Section (난류침투가 사각단면 T분기관 내 누설유동에 의해 발생한 열성층 현상에 미치는 영향)

  • 홍석우;최영돈;박민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. $textsc{k}$-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of the main flow in the duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from the main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.