• Title/Summary/Keyword: Thermal Control

Search Result 3,093, Processing Time 0.033 seconds

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

Thermal Analysis of TRIO-CINEMA Mission

  • Yoo, Jae-Gun;Jin, Ho;Seon, Jong-Ho;Jeong, Yun-Hwang;Glaser, David;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • Thermal analysis and control design are prerequisite essential to design the satellite. In the space environment, it makes satellite survive from extreme hot and cold conditions. In recent years CubeSat mission is developed for many kinds of purpose. Triplet Ionospheric Observatory (TRIO)-CubeSat for Ion, Neutral, Electron, MAgnetic fields (CINEMA) is required to weigh less than 3 kg and operate on minimal 3 W power. In this paper we describe the thermal analysis and control design for TRIO-CINEMA mission. For this thermal analysis, we made a thermal model of the CubeSat with finite element method and NX6.0 TMG software is used to simulate this analysis model. Based on this result, passive thermal control method has been applied to thermal design of CINEMA. In order to get the better conduction between solar panel and chassis, we choose aluminum 6061-T6 for the material property of standoff. We can increase the average temperature of top and bottom solar panels from $-70^{\circ}C$ to $-40^{\circ}C $ and decrease the average temperature of the magnetometer from $+93^{\circ}C$ to $-4^{\circ}C$ using black paint on the surface of the chassis, inside of top & bottom solar panels, and magnetometer.

THERMAL BALANCE MODELLING AND PREDICTION FOR A GEOSTATIONARY SATELLITE (정지궤도 위성의 열평형 시험 모델링 및 예비 예측)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.142-147
    • /
    • 2009
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean and meteorological observations. It will be tested under vacuum condition and very low temperature in order to verify thermal design of COMS. The test will be performed by using KARI large thermal vacuum chamber, which was developed by KARI, and the COMS will be the first flight satellite tested in this chamber. The purposes of thermal balance test are to correlate analytical model used for design evaluation and predicting temperatures, and to verify and adjust thermal control concept. KARI has plan to use heating plates to simulate space hot condition especially for radiator panels such as north and south panels. They will be controlled from 90K to 273K by circulating GN2 and LN2 alternatively according to the test phases, while the shroud of the vacuum chamber will be under constant temperature, 90K, during all thermal balance test. This paper presents thermal modelling including test chamber, heating plates and the satellite without solar array wing and Ka-band reflectors and discusses temperature prediction during thermal balance test.

  • PDF

Development of High Efficiency Solar Power Generation with Two-axis Tracking Control (양축 추적제어에 의한 고효율 태양열 발전시스템의 개발)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1721-1726
    • /
    • 2011
  • Recently, interest in renewable energy is increased due to exhaustion of fossil fuel and environmental pollution all over the world, therefore the solar power generation using solar energy is many researched. The solar power generation is required solar tracking control and high concentration solar thermal collector because generation performance is depended on concentrator efficiency. This paper proposes high efficiency solar power generation with two-axis tracking control using dish-type solar thermal collector that has excellent thermal collector performance and tracking algorithm that can be accurately tracked solar position. This paper proves validity through analysis with accuracy of tracking algorithm and generating efficiency.

Thermal Crack Control Using Optimized Steps of Concrete Placement in Massive Concrete Foundation (대형 기초 콘크리트의 분할타설 방법을 고려한 수화열에 의한 온도균열 제어 대책)

  • 김동규;조선규;김은겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1169-1174
    • /
    • 2000
  • Since the cement-water reaction in exothermic by nature, the temperature rise within a large concrete mass. Significant tensile stresses may develop from the volume change associated with the increase and decrease of the temperature with the mass concrete. There thermal stresses will cause temperature-related cracking in mass concrete structure. These typical type of mass concrete include mat foundation, bridge piers, thick wall, box type walls, tunnel linings, etc. Crack control methods can be considered at such stages as designing, selecting the materials, and detailing the construction method. Temperature and analysis was performed by taking into consideration of the cement type and content, boundary and environment conditions including the variations of atmospheric temperature and wind velocity. This is paper, the effect of separate placement of thermal crack control footing was analysed by a three dimensional finite element method. As a result, using this method, thermal crack control can be easily performed for structures such as mat structures.

  • PDF

Construction Techniques for Crack Control of Underground Box Structures (지하철 박스 구조물의 수화열 해석 및 온도균열 제어 방안)

  • 차수원
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.153-159
    • /
    • 2001
  • Recently, the underground reinforced concrete(RC) box structures have been increasingly built in Korea. In such structures, the heat of hydration may cause serious cracking problems. The RC box structures are classified in this category that needs much attention to control the hydration heat during construction, which causes the restraining effects on the boundaries. The purpose of the present study is to develop the rational construction method to control the thermal cracking problem of the box structures. In this study, the causes and mechanism of thermal cracking according to construction stages in the RC box structures are thoroughly analyzed. The major influencing variables are studied through the finite element analysis which affect the thermal cracking of RC box structures. The research results of the present study can be efficiently used for the control of cracking of box structures during construction stages.

  • PDF

Temperature Control of Superheater Steam in Thermal Power Plant (화력발전소의 과열기증기의 온도제어)

  • Shin, Hwi-Beom;Lee, Soon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2006-2011
    • /
    • 2010
  • The superheater in the thermal power plant makes the wet steam into the dry steam with high temperature and high pressure by using the boiler heat. The dry steam pressure rotates the turbine-generator system. The efficiency and life time of the boiler heavily depends on the steam temperature regulation. The steam temperature can be deviated from the reference by the MW demand of the power plant. It is therefore required that the PI(proportional-integral) controller should be robust against the disturbance such as the MW demand. In this paper, the PI controller with the integral state predictor is proposed and applied to regulate the steam temperature of the superheater, and it is compared with the conventional PI controller operated in the thermal power plant in view of control performance.

Effect of the Thermal Changes of Five-shu-points(五輸穴) of the Lung Meridian with Acupuncture Stimulation on Taeyon(L9, 太淵) (태연(太淵)(L9)자침(刺鍼)이 수태음폐경(手太陰肺經)의 오수혈(五輸穴) 영역(領域) 온도변화(溫度變化)에 미치는 영향(影響))

  • Song, Beom-Yong;Yook, Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.17 no.3
    • /
    • pp.219-232
    • /
    • 2000
  • Objective : The meridian and the acupuncture point of oriental medicine are very important in the department of acupuncture and moxibustion. Recently, we needed to study on the phenomenon of the meridian and acupuncture point with objective data. And then, I made a study of effects on the thermal changes of Five-shu-points(五輸穴) of the Lung meridian with acupuncture on Taeyon($L_9$, 太淵), using Digital infrared thermal imaging(D.I.T.I). Method : This study researched into clinical statistics for 60 men who are in good health. The objective was divided into two groups, one was the control group(CON, N=30) and the other was acupuncture group(ACU, N=30). The first, I took a picture for 60 men with the Digital infrared thermal imaging(D.I.T.I.). After 10 minutes, I took a second picture for each group following experimental methods. Results : I. The Mean temperature of Sasang($L_{11}$), Oje($L_{10}$), Taeyon($L_9$), Kyonggo($L_8$), Choldaek($L_5$) and Taenung($P_7$) area in adult men with good health, made a no significant difference with left and right side points. 2. Acupuncture group with acupuncture stimularion on Taeyon($L_9$) had a effect on much thermal changes of Sasang($L_{11}$), Oje($L_{10}$), Taeyon($L_9$), Kyonggo($L_8$) and Choldaek($L_5$) than control group. The thermal changes of the area which is a meridian point in the Lung Meridian of acupuncture group differed from control group with significant decrease and increase following the decreasing or increasing temperature class. Each class of ascent and descent thermal change was statistically significant value compared with control group. 3. Acupuncture group with acupuncture stimulation on Taeyon($L_9$) had not a effect on thermal changes of Taenung($P_7$) area than control group. And the increasing and decreasing temperature class of the acupuncture group did not significantly differ from control group. Conclusion : I could think that the acupuncture on Taeyon($L_9$) affected the thermal change of the area which is the Five-shu-points in the Lung Meridian. And then I could relate these results with the existence of the meridian and acupuncture point.

  • PDF

Design and Performance Test of a Cryogenic Blower for Space Thermal Environment Simulation (우주 열환경 모사용 소형 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Ahn, Sungmin;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.833-839
    • /
    • 2013
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in a harsh space environment which is represented by extremely cold temperatures and vacuum conditions. A thermal vacuum chamber which consists of a vacuum vessel, a pumping system, and a thermal control system are used to perform thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the closed loop thermal control system for thermal vacuum chambers. This paper describes the fan design of the cryogenic blower, the design of the thermal protection interface between the driving part and the fluid part, which were verified by thermal and structural analyses. The performance of the cryogenic blower is confirmed by similarity test on the test bench.

A Study on the Thermal Sensation Vote of the Traditional Housing in Summer (전통주택의 하절기 실내 온열감 평가에 관한 연구)

  • Kang, Sang-Woo;Jeon, Ji-Hyeon;Shin, Yong-Gyu;Min, Byeong-Cheol;Kook, Chan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.488-491
    • /
    • 2006
  • There is a principle of Korean Traditional Housing to be adapted for the nature using adaptable shapes to regional climate and easily available materials from the region then these environmentally friendly characteristics keep indoor environment from climate changes. These environmentally friendly characteristics to control indoor environment are very available for contemporary housing in that current issues, housing amenity and wellbeing, have basic goals same with what Korean Traditional Housing has. Therefore, this study begins to suggest fundamental data on indoor thermal environment control elements of Korean Traditional Housing to adapt those into contemporary housing through measurement of indoor thermal environment elements and evaluation on thermal sensation vote for Korean traditional housing. There was 24 hours measurement for indoor and outdoor thermal environmental elements to figure out competence to control indoor thermal environment of Korean Traditional Housing in summer. And subjective tests with 11 subjects was held in the morning, afternoon and night at intervals of 3${\sim}$4 hours to evaluate feeling and amenity for temperature and humidity of users.

  • PDF