• 제목/요약/키워드: Theoretical electrical resistance

검색결과 100건 처리시간 0.022초

게이트저항에 따른 IGBT의 과도 특성 해석 (Analysis of Transient Characteristics for IGBTs with Gate resistances)

  • 류세환;이명수;원창섭;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.173-174
    • /
    • 2006
  • In this paper we proposed transient model for NPT(Non Punch-Through) IGBT(Insulated Gate Bipolar Transistor) with gate resistances. As gate resistance increases, turn-off time increases. But If gate resistance is small, overshoot voltage increase. To analyze the effect of gate resistance, the transient model is made and the experiments are conducted. We used gate resistances of values; 8[$\Omega$], 140[$\Omega$], 810[$\Omega$] for simulations and experiments. We compared theoretical and experimental results and obtained good agreements.

  • PDF

Theoretical resistance in cylindrical electrodes with conical tip

  • Hong, Chang-Ho;Kim, Jin-Seop;Chong, Song-Hun
    • Geomechanics and Engineering
    • /
    • 제30권4호
    • /
    • pp.337-343
    • /
    • 2022
  • The electrical resistivity method is a well-known geophysical method for observing underground conditions, (such as anomalies) and the properties of soil and rock (such as porosity, saturation, and pore fluid characteristics). The shape of electrodes used in an electrical resistivity survey depends on the purpose of the survey and installation conditions. Most electrodes for field applications are cylindrical for sufficient contact with the ground, while some are conically sharpened at their tips for convenient penetration. Previous study only derived theoretical equations for rod-shaped electrodes with spherical tips. In this study, the theoretical resistance for two cylindrical electrodes with conical tips is derived and verified experimentally. The influence of the penetration depth and tip on the measurement is also discussed.

LB막이 누적된 QCM의 저항 및 주파수 특성해석 (Resistance and Frequency Properties Analysis of QCM Coated with LB Films)

  • 강현욱;진철남;김정명;권명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.465-467
    • /
    • 1997
  • The oscillating properties of quartz Crystal Microbalance(QCM) were analyzed by electrical measurement. We tried to analyze the properties of quartz crystal coated with Langmuir-Bladgett(LB) films using the frequency and resistance at resonance in the electrical equivalent circuit. The resonant frequency was decreased linearly as to layers of LB films, however, there are some gap between theoretical values, Sauerbrey's equation and experimental values. The resistance was increase nonlinearly as to layers.

  • PDF

트라이볼로지 기소의 멀티접촉에서 전기접촉저항 모델해석에 관한 연구 (Analysis of Electrical Contact Resistance Model in Multi-Contact of Tribological Elements)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제12권4호
    • /
    • pp.52-59
    • /
    • 1996
  • The results of the electrical contact conductivity of multi-contact spots accounting the surface roughness and the non-conductive films of different origins such as air, water, cutting oil, and machining oil are presented. The array of metal spheres compressed between two flat plates has been used for simulation of the contact behavior of multiple contact of solids, under normal loading. Measurement of electrical contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spot number and array on conductivity of contact has been evaluated. The results of the experiments show that the contact resistance are closely related to the number of loading cycles, form of surface roughness, and presence of non-conductive films that reduce the size of the real electrical contact spots.

수조모델 실험에 의한 접지저항 추정 (presumption of Earth Resistance by Water Tank Model)

  • 고희석;최종규;김주찬;이충식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.125-131
    • /
    • 2002
  • It is very important to assume potential distribution to be generated in electrode environs and grounding resistance by current beforehand, when incoming at grounding electrode to plan efficient grounding facilities In this paper, we analyzed grounding resistance through a simulation experiment by a water tank scaled model electrode of the rectangular earth plate, a theoretical Calculation result of the rectangular earth plate and measurement of grounding resistance buried rectangular earth plate analysing earth surface potential.

  • PDF

피부의 전기적 저항에 대한 이론적 모델 (Theoretical Model for the Electrical Resistance of Skin)

  • 오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제26권3호
    • /
    • pp.207-213
    • /
    • 1996
  • The kinetic change of electrical resistance of hairless mouse skin as a function of ionic strength of the bathing medium was determined from impedance measurements. After increasing (decreasing) the ionic strength of the bathing medium, resistance decreased (increased) continuously with time, finally reaching an equilibrium value. We have modelled this process, using nonsteady-state diffusion kinetics. The results show semi-quantitative correlation between theoretically derived and experimentally obtained values. Overall, this work provides further mechanistic insight into ion-conduction through the skin.

  • PDF

전극의 기하학적 형상이 전기비저항 탐사에 미치는 영향: 수치 해석 연구 (Influence of electrode geometry on electrical resistivity survey: Numerical study)

  • 김태영;이승훈;류희환;정성훈
    • 한국터널지하공간학회 논문집
    • /
    • 제25권2호
    • /
    • pp.101-120
    • /
    • 2023
  • 전기비저항 탐사 방법은 매질의 표면에 관입된 두 전극의 전위차와 전류와의 관계를 통해 전기 저항을 측정하고, 형상 계수를 이용하여 매질의 고유한 특성인 전기비저항을 계산한다. 현장 및 실대형 크기의 전기비저항 실험은 전극과 매질 사이의 접촉 면적이 적고, 전극 간 거리가 충분하기 때문에 계산상 편의를 위해서 동일한 표면적을 가진 반구형으로 치환하여 전기비저항을 산정한다. 하지만, 실내 소규모 크기의 전기비저항 실험은 전극의 지오메트리(전극의 관입 깊이, 전극사이의 거리, 전극의 길이와 반지름 크기)로 인해서, 등전위면과 전류 흐름이 달라지게 되므로, 궁극적으로 전기비저항값의 오차를 야기한다. 본 연구는 기존 연구에서 유도된 4가지 전극 형상(반구, 원기둥, 반구형 팁을 가진 원기둥, 콘형 팁을 가진 원기둥)에 따른 전기 저항 이론식을 정리하고, 전극 형상을 고려한 전기 저항 수치 해석을 실시하였으며, 이론식과 수치 해석 결과들의 비교를 통해서 개발된 수치 해석 모듈을 검증하였다. 또한, 각 전극 형상에 따른 전극 주변과 전극사이에 형성된 전기 저항 분포를 분석하였다. 추가적으로, 현장 전기비저항 탐사에서 주로 사용되는 콘형 팁을 가진 원기둥 전극의 전기적 특성에 따른 전류 흐름 분포를 고찰하였다.

Matlab을 이용한 PV모듈의 I-V시뮬레이션 관한 연구 (Study on I-V simulation for PV module with matlab)

  • 홍종경;정태희;강기환;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.1-6
    • /
    • 2009
  • This paper estimates numerically cells the electrical characteristics of the PV module with environmental changes such as shunt resistance, series resistance, temperature, irradiance. Series resistance $R_s$ including diode characteristic resistance $r_d$ is derived from the p-n junction diode model. I-V characteristics of this model with series resistance $R_s$ are simulated on Matlab. Finally, theoretical I-V characteristics are compared with those of solar simulator. Those results agreed well within the manufacturer's maximum error range 3%

수조모델 실험에 의한 접지저항 추정 (Estimation of Groungding Registance by Water Tank Model)

  • 최종규;고희석;이충식;김주찬
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.41-48
    • /
    • 2003
  • 접지 시설의 효율적인 시설 계획을 위해서는 시공 전에 접지전극에 전류가 유입할 때 접지 전극주변에 발생하는 전위분포 및 전류에 의한 접지저항을 추정하는 것이 접지 설계에 있어서 매우 중요하다. 본 논문에서는 사각판상의 접지전극을 대지에 직접 시공 매설하여 지표면 전위의 분석으로 접지저항을 측정하고, 또한 사각판상 접지 저항 값의 이론적 계산식에서 구한 접지저항값과 축소된 사각판상의 접지전극 모델을 수조에 넣고 모의 실험을 통해 측정된 접지저항값을 비교·분석하였다.

병렬 접속에 의한 접지저항에 관한 연구 (A Study on Grounding Resistance by Parallel Connection)

  • 고희석;최종규;류희석;김주찬
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.307-312
    • /
    • 2002
  • For accuracy of an experiment, measure changing of grounding resistance by short period after construction and investigated the efficiency of grounding's different methode of parallel connection. We could confirm on measurement's accuracy, error through comparing the theoretical value and measured value. Therefore, reduction ratio can be expected from execution measurement to receive a target resistance value. By the result, we could evaluate the method of rod grounding electrode's proper execution

  • PDF