Transformer-Less Single-Phase Four-Level Inverter for PV System Applications

  • Yousofi-Darmian, Saeed;Barakati, Seyed Masoud
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1233-1242
    • /
    • 2014
  • A new inverter topology for single-phase photovoltaic (PV) systems is proposed in this study. The proposed inverter offers a four-level voltage in its output terminals. This feature results in easier filtering in comparison with other conventional two-level or three-level inverters. In addition, the proposed four-level inverter (PFLI) has a transformer-less topology, which decreases the size, weight, and cost of the entire system and increases the overall efficiency of the system. Although the inverter is transformer-less, it produces a negligible leakage ground current (LGC), which makes this inverter suitable for PV grid-connected applications. The performance of the proposed inverter is compared with that of a four-level neutral point clamped inverter (FLNPCI). Theoretical analysis and computer simulations verify that the PFLI topology is superior to FLNPCI in terms of efficiency and suitability for use in PV transformer-less systems.

Design of 1 MVA Single Phase HTS Transformer with Pancake Windings Cooled by Natural Convection of Sub-cooled Liquid Nitrogen

  • Kim, Woo-Seok;Kim, Sung-Hoon;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Lee, Don-Kun;Park, Yeon-Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.34-37
    • /
    • 2003
  • A 1 MVA single-phase high temperature superconducting (HTS) transformer with BSCCO-2223 wire was designed in this paper. The rated voltages of each sides of the transformer are 22.9 kV and 6.6 kV respectively. Double pancake HTS windings arranged reciprocally will be used for the transformer windings, because of the advantages of insulation and distribution of surge voltage in case of a large power and high voltage transformer. Single HTS wire was used for the primary windings and four parallel wires were used for the secondary windings of the transformer with transposition. A core of the transformer was designed as a shell type core separated with the windings by a cryostat made of GFRP with a room temperature bore. The operating temperature of the HTS windings will be about 65K with sub-cooled liquid nitrogen. A cryogenic cooling system using a GM-cryocooler for this HTS transformer by natural convection of liquid nitrogen was designed. This type of cooling system can be a good option for compactness, efficiency, and reliability of the HTS transformer.

단상 1MVA 고온초전도 변압기의 누설임피던스 3차원 해석 및 시험 (Test and Analysis of 3-D of Leakage Impedances in a Single-Phase 1MVA HTS Transformer)

  • 김성훈;김우석;이상진;최경달;주형길;홍계원;한진호;한송엽;송희석;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1003-1005
    • /
    • 2003
  • In this paper, 3-D nonlinear electromagnetic analysis of a single phase 1MVA 22.9 kV/6.6 kV high temperature superconducting(HTS) transformer with double pancake windings was accomplished. The characteristics of 1MVA HTS transformer such as The efficiency, voltage regulation and % impedance voltage drop were obtained by the 3-D non-linear electromagnetic analysis. And in order to verify the 3-D non-linear electromagnetic analysis of a single phase 1MVA HTS transformer, a 1MVA test transformer with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The energy conservation method to perform the analysis of leakage impedances of both a 1MVA HTS transformer and test transformer was used. The characteristic analysis such as efficiency, voltage regulation and % impedance voltage drop of transformer was performed. And the obtained values of both 1MVA HTS transformer and test transformer were compared.

  • PDF

Investigation and Mitigation of Overvoltage Due to Ferroresonance in the Distribution Network

  • Sakarung, Preecha;Bunyagul, Teratam;Chatratana, Somchai
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.300-305
    • /
    • 2007
  • This paper reports an investigation of overvoltages caused by ferroresonance in the distribution system, which consists of a bank of open-delta single-phase voltage transformers. The high voltage sides of the voltage transformer are connected to the distribution system via three single-phase fuse cutouts. Due to the saturation characteristic of the transformer cores, ferroresonance can occur in the condition that the transformer is energized or deenergized with single-phase switching operation of the fuse cutouts. The simulation tool based on EMTP is used to investigate the overvoltages at the high side of voltage transformer. Bifurcation diagrams are used to present the ferroresonance behavior in ranges of different operating conditions. The simulation results are in good agreement with the results from the experiment of 22 kV voltage transformers. The mitigation technique with additional damping resistors in the secondary windings of the voltage transformers will be introduced. Brief discussion will be made on the physical phenomena related to the overvoltage and the damage of voltage transformer.

단상 10MVA 고온초전도 변압기 개념설계 (Conceptual Design of Single Phase 10MVA HTS Transformer)

  • 석복렬;최명준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.42-46
    • /
    • 2002
  • This research is conducted with the object of Piling up the foundation of design technologies for high temperature superconducting (HTS) power transformer which is thought to be as a powerful power transformer of next generation. In this study, not only the theoretical design of high temperature superconducting (HTS) transformer but also the arrangements of superconducting tape and the cooling method have been conducted. Moreover, electromagnetic analyses using finite element method (FEM) were conducted to confirm the efficiency of the designed transformer.

Improved Single-Stage AC-DC LED-Drive Flyback Converter using the Transformer-Coupled Lossless Snubber

  • Jeong, Gang-Youl;Kwon, Su-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.644-652
    • /
    • 2016
  • This paper presents an improved single-stage ac-dc LED-drive flyback converter using the transformer-coupled lossless (TCL) snubber. The proposed converter is derived from the integration of a full-bridge diode rectifier and a conventional flyback converter with a simple TCL snubber. The TCL snubber circuit is composed of only two diodes, a capacitor, and a transformer-coupled auxiliary winding. The TCL snubber limits the surge voltage of the switch and regenerates the energy stored in the leakage inductance of the transformer. Also, the switch of the proposed converter is turned on at a minimum voltage using a formed resonant circuit. Thus, the proposed converter achieves high efficiency. The proposed converter utilizes only one general power factor correction (PFC) control IC as its controller and performs both PFC and output power regulation, simultaneously. Therefore, the proposed converter provides a simple structure and an economic implementation and achieves a high power factor without the need for any separate PFC circuit. In this paper, the operational principle of the proposed converter is explained in detail and the design guideline of the proposed converter is briefly shown. Experimental results for a 40-W prototype are shown to validate the performance of the proposed converter.

변압기 자화 에너지를 이용한 새로운 단일전력단 고역률 컨버터 (New Single-Stage High Power Converter Using Transformer Magnetizing Energy)

  • 문건우;노정욱;정영석;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.35-38
    • /
    • 1996
  • A new high power factor converter using transformer magnetizing energy for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

일반화된 Hough 변환을 위한 특수 목적 VLSI 시스템 설계에 관한 연구 (Specialized VLSI System Design for the Generalized Hough Transform)

  • 채옥삼;이정헌
    • 전자공학회논문지B
    • /
    • 제32B권3호
    • /
    • pp.66-76
    • /
    • 1995
  • In this research, a mesh connected VLSI structure is proposed for the real time computation of the generalized Hough transform(GHT). The purpose of the research is to design a generalized Hough transformer that can be realized as a single chip processor. The GHT has been modified to yield a highly parallel structure consisting of simple processing elements(PEs) and communication networks. In the proposed structure, the GHT can be computed by first assigning an image pixel to a PE and performing shift and add operations. The result of the CAD circuit simulation shows that it can be computed in the time proportional to the number of pixels in the pattern. In addition to the Hough transformer, the peak detector has been designed to reduce 1)the number of the I/O operations between the transformer and the host computer and 2) the host computer's burden for peak detection by transmitting only the local peaks detected from the transformed accumulator. It is expected that the proposed single chip Hough transformer with peak detector makes a fast and inexpensive edge based object recognition systems possible for many industrial and military applications.

  • PDF

유한요소법에 의한 변압기 인덕턴스 계산 (The Calculation of Transformer Inductance by the Finite Element Method)

  • 배진호;노채균
    • 대한전기학회논문지
    • /
    • 제34권7호
    • /
    • pp.267-275
    • /
    • 1985
  • The finite element method for calculating single phase transformer inductance is presented in this paper. There are three basic definitions of saturated transormer inductance. The set of nonlinear finite element equations is solved by the Newton-Raphson method which assures nearly quadratic convergence of the iteration process. The effect of perturbation of currents of this transformer is used to calculate the saturated winding inductance. This approach is used to calculate the apparent, effective and incremental inductance of single phase transformer. The apparent inductance is in good agreement with resting result. The approach enabled one to study the variation of winding inductance according to the saturation levels in the core at any operating point.

  • PDF