• Title/Summary/Keyword: The pulse

Search Result 10,394, Processing Time 0.043 seconds

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Circuit (펄스다중화 보조회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Jon Young-Soo;Baek Seung-Taek;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.238-244
    • /
    • 2005
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter, The operational feasibility of proposed system was verified by computer simulations with PSCAD/EMTDC software and experimental works with 2kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel cell power system.

Theoretical Study of Pulse Circuits with the Load Variation for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 관한 부하의 변화를 고려한 펄스회로의 이론적 연구)

  • Kim, Young-Ju;Bang, Sang-Seok;Lee, Chae-Han;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.106-112
    • /
    • 2016
  • The high-voltage pulse generator consists of transformers of fundamental wave and harmonic waves, and shunt capacitors. The pulse has the fundamental wave and the harmonic waves that have been as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed by using transformer equivalent circuits with the effect of load and simulated in time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 2.0kV. In high voltage circuit, capacitors are related to frequency band pass characteristics. Also, it is shown that the voltage of output pulse increases according to the growth of load.

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Bridge Circuit (펄스다중화 보조브리지회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Han, B.M.;Baek, S.T.;Jon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.31-35
    • /
    • 2004
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter. The operational feasibility of proposed system was verified by computer simulations with PSCAD/TMTDC software and experimental works with 3kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel fell power system.

  • PDF

Multistage Pulse Jamming Suppression Algorithm for Satellite Navigation Receiver

  • Yang, Xiaobo;Feng, Jining;Xu, Ying
    • Journal of Information Processing Systems
    • /
    • v.18 no.1
    • /
    • pp.89-96
    • /
    • 2022
  • A novel multistage pulse jamming suppression algorithm was proposed to solve the anti-pulse jamming problem encountered in navigation receivers. Based on the characteristics of the short duration of pulse jamming and distribution characteristics of satellite signals, the pulse jamming detection threshold was derived. From the experiments, it was found that the randomness of pulse jamming affects jamming suppression. On this basis, the principle of the multistage anti-pulse jamming algorithm was established. The effectiveness of the anti-jamming algorithm was verified through experiments. The characteristics of the algorithm include simple determination of jamming detection threshold, easy programming, and complete suppression of pulse jamming.

Power and Collection Characteristics of Superimposed Pulse Electrostatic Precipitator (중첩펄스 전기집진기의 전력 및 집진특성)

  • Seo, Gyeong-Won;Lee, Chang-Sin;Lee, Jeong-Seok;Chae, Jae-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.3
    • /
    • pp.177-185
    • /
    • 2000
  • In this study, the characteristics of various electricity and high resistivity ash collection were measured at superimposed nanosecond pulse energization. The pulse was generated through the hydrogen thyratron. Superimposed pulse was nanosecond duration pulse that had fast pulse rising time 100[ns], short pulse width 500∼850[ns] and pulse fall time 400∼750[ns]. The results of this study are summarized as followings; Frist, compared with the DC ESP(electrostatic precipitator), superimposed pulse ESP could induce higher peak voltage, and had the about 30[%] reduction of ESP collection area and 50∼80[%] reduction of power consumption. showing the same efficiency. Second, enhancement factor H had 1.9∼3.6 with the increase of migration velocity.

  • PDF

A Study on the Arterial Pulse Wave Measuring System of an Oral Cavity (구강 내부 맥파 계측을 위한 센서 시스템 연구)

  • Kim, Kyung-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.43-47
    • /
    • 2007
  • In this paper, we propose a novel sensor system for measuring the arterial pulse in an oral cavity. In order to measure pulse wave in oral cavity, the proposed system is designed with reflection type arterial wave sensor, not by using transmission type arterial pulse wave sensor. Driving circuit through pulse current is designed for solving self-heating problem of LED. The effectiveness of the proposed sensor system is compared with pulse wave between pulse wave of oral cavity and other body parts as well as with characteristic measurements. The experiment shows that the proposed sensor system is adaptive to capturing consecutive and meaningful biometric signals through the variation of pulse wave changes in oral cavity when exercising. The study result expects to design and develop mobile sensors which could be adapted to healthcare devices.

  • PDF

The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors (가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성)

  • 이유수;정종한;정현주;김문환;김희제
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.

A Research of characteristics of left/right pulse wave and blood vessel using Korean medicine pulse diagnosis (맥진기를 이용한 좌우 맥파 및 혈관 특성 연구)

  • Kang, JinHo;Lee, Han-Byul;Kim, Ki-Wang;Kwon, Jung-Nam;Lee, Byung-Ryul
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.155-165
    • /
    • 2014
  • Objectives: The pulse diagnosis to identify the symptoms has been considered important in Korean medicine. The position and character of disease would be confirmed by pulse diagnosis of left and right radial artery. This paper is to analyze the characteristics and differences of left and right blood vessels. Methods: In this study, left and right radial artery and dorsalis pedis artery was measured and analyzed by using condenser typed pulse analyzer. Commercially available pulse analyzer was used to measure the radial artery. The pulse wave was measured in 20 laboratory healthy men and women. The blood vessel aging degree and index of augmentation of blood vessel was obtained from the measured pulse wave graph and the characteristics and differences of the left and right blood vessel was analyzed. Results: The significant difference of pulse transit time between the right handed and non-right handed was not found. The correlation of radial artery and dorsalis pedis artery had no significant difference. By obtaining the blood vessel aging index (AGI) and augmentation index (AI) of blood vessel at the left and right radial artery, the significant difference between right handed and non-right handed was not found. Conclusions: The result of this study would help to explain the characteristic of blood vessel with respect to the left and right handed. We suggest that research of pulse wave of the left and right blood vessel using pulse analyzer should be needed in further study.

Development of Dual Pulse SRM (이중펄스 고체추진기관 개발)

  • Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.69-72
    • /
    • 2011
  • The ground tests of the dual pulse solid rocket motors(SRM) were performed to prove the performance of the developed dual pulse solid rocket motors. To achieve dual pulse, pulse seperation device(PSD) and independent ignition systems were installed between the 1st pulse motor and the 2nd pulse motor. The three major development goals are as follow. First, the total impulse of the dual pulse SRM must be over 90% of the single SRM which has same envelopment and weight. Second, the ignition of the 2nd pulse motor can be started at any time between 0 and 60 seconds after termination of the 1st pulse motor. Last, the rupture disk of PSD must not be broken at the 1st pulse pressure, but be broken at below 30% of the 2nd pulse operating pressure. The results of the ground tests satisfied the development goals.

  • PDF

Review of the Domestic Trend of Pulse Diagnosis Studies in Korea (맥진 연구의 국내 동향에 대한 고찰)

  • Kan, Sei-young
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.6
    • /
    • pp.1152-1168
    • /
    • 2019
  • Objectives: The aim of this study was to present several proposals for future pulse diagnosis practice and research by investigating the trend of pulse diagnosis studies in Korea. Methods: We searched online medical databases, including National Discovery for Science Leaders (NDSL), the Oriental Medicine Advanced Searching Integrated System (OASIS), the Research Information Sharing Service (RISS), and the Korean Traditional Knowledge Portal (KTKP), for pulse diagnosis articles in Korea. We selected articles on pulse diagnosis but excluded duplicate articles, articles irrelevant to pulse diagnosis, and articles published in foreign countries. Results: In the first screening, 801 articles were selected. We found 251 articles and classified them according to category. The medical engineering field had 148 articles. A total of 24 articles were related to algorithms for pulse wave detection, 34 to sensors, five to pressurization technology, 16 to systems, 11 to remote medical service, five to mobiles, nine to trends, and 44 to basic research. The Korean medicine field had 103 articles. A total of 41 articles were devoted to literature reviews, 20 to case reports, 11 to constitutional medicine, six to experimental studies, and 25 to relevant research. Conclusion: More efforts to practice pulse diagnosis for various diseases should be made and the results actively published.