기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구 (A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board)

  • 김혜정;송규동;이윤규
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구 (A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.

복토 주택의 외벽면 복토 두께 변화에 따른 열부하 패턴에 관한 연구 (A Study on the Thermal Load Patterns for a Exterior Wall in a House According to a Variation of Earth Sheltering Thickness)

  • 이재혁;최원기;서승직;조동우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.807-812
    • /
    • 2008
  • The various attempts is made to solve the energy and environment problems. In addition, people interested in their life quality want the more eco-friendly living space. So we suggested that the earth-sheltered house could be one of the eco-friendly and low energy consuming houses to meet the social interest. And we also made data for design of the earth-sheltered house to be applicable to climate of Korea. In this study, a simulation was performed to estimate a boundary temperature according to earth sheltering thickness at the earth-sheltered part(exterior wall) in the case of earth sheltering on the plane ground not using a sloped site. And we analyzed the reduction of a thermal load by using this boundary temperature. We also compared a case of earth sheltering at the vertical wall with a case of earth sheltering at the roof to know the thermal reduction effect of a case of earth sheltering at the vertical wall.

  • PDF

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

품질기능전개를 이용한 플라이어의 인간공학적 디자인 (Application of Quality Function Deployment to Ergonomic Design of a Plier)

  • 박희석;이미란
    • 대한인간공학회지
    • /
    • 제26권4호
    • /
    • pp.85-90
    • /
    • 2007
  • This study shows a way to develop ergonomic design of a plier through quality function deployment (QFD) approach. User needs for pliers, as well as the engineering characteristics which have influence on the ergonomic quality of pliers were determined from the interviews and questionnaires with various user groups. This information was entered in the house of quality, and the results show that the handle is the most important quality factor. A new model was proposed in which ergonomic and gender aspects were considered. QFD is considered a suitable method especially for the manufacturing and/or design fields where biomechanical or physiological background is not present.

고품질 다수성 생강 품종육성을 위한 국내 유전자원의 농업적 특성 평가 (Evaluation of Agronomic Characteristics Indigenous Germplasm for Development of High Quality and Yield of Ginger (Zingiber officinale Rosc.))

  • 최재을;김정선;장원석
    • 한국자원식물학회지
    • /
    • 제12권1호
    • /
    • pp.38-42
    • /
    • 1999
  • 본 실험은 고품질 다수성 생강 품종육성에 필요한 기초 자료를 얻기위해 국내에서 수집한 우량생강 24클론을 포장과 하우스에서 재배하여 주요 작물학적 특성을 조사한 결과 다음과 같다. 조사된 클론중에서 수량과 6-gingerol 함량에서 높은 유의차가 인정되었다. 포장에서는 CG9579(3520kg/10a)의 수량이 가장 높았고, 그 다음으로 CG95134, CG9512, CG96109, CG9596 순이었다. 우량 클론으로 선발된 클론중 6-gingerol 함량을 조사한 결과 CG9579가 4.44mg/g로 가장 높았으며, 그 다음으로는 CG9583이 4.35mg/g, CG95134가 4.32mg/g순이었다. 하우스에서 는 수량이 CG9503과 CG9521 클론이 10a당 5529kg으로 가장 높았고, CG9515, CG9578, CG9579, CG96103 그리고 CG95105 클론이 10a당 4,000kg이상의 수량을 보았다.

  • PDF

실버타운의 사례(事例)를 통한 공용공간구성요소(公用空間構成要素)와 면적(面積)에 관한(關限) 연구(硏究) - 고층형 수도권 시설의 공용공간을 중심으로 - (A Case Study on the Spatial Organization in Public Areas of Silver Town)

  • 최웅;이상호
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.151-158
    • /
    • 2006
  • Medical technology being developed, the increase of the aged population brings about many changes in financial standard, consciousness and lifestyle. And the increase of a nuclear family and a professional woman makes their family not to be able to support them anymore. Because aged people also don't want to rely on their family, aged people households are growing gradually. These causes make a house and a living environment of aged people to new social problems and these became elements to determine the living quality. In case of advanced nations a house considered of the physical character of aged people has been planned and they can live with various services in their houses and community that they are living without moving: But a hou! se for aged people is initial stage in Korea. And most facilities are poor and just for protection and accommodation. Although concerning a house for the aged according to revised the aged welfare law, companies are waiting to build because of problems of cognition and regulation. Therefore the plan considered of the character of the aged is being needed for the independent and comfortable living of the aged.

재한 중국 조선족의 생활 형태 및 삶의 질에 관한 연구 (A Study on Real-Life Conditions and Quality of Life among Korean-Chinese in Korea)

  • 최덕경
    • 가족자원경영과 정책
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 2001
  • The purpose of this study was not only to identify real-life conditions of Korean-Chinese in Korea(clothing habits, eating habits, housing habits, economic life and leisure activities) but also to reveal the related variables that shall affect life quality. The subjects were selected from Korean-Chinese in Korea related to ‘Compatriots House’. The survey was conducted from June 20th to July 5th, 2000. A total of 225 questionnaires out of 350 were used as the final data analysis. All data were analyzed using the SAS/PC for frequency, percentage, F-test and Regression analysis. The study revealed the following results. 1. Significant differences were found in life quality of Korean-Chinese in Korea according to age(p<.05), optimum income (p<.001), health condition(p<.001), education level(p<.005), and entry motivation(p<.05). 2. Variable such as optimum income(β=.334) education level(β=-.190), monthly income(β=.170), health condition(β=.151), and self-esteem(β=.133) affected life quality of Korean-Chinese in Korea. Korean-Chinese’s life quality was explained by these variable(35%). The optimum income variable was the primary influential factor.

  • PDF

신축 공동주택 베이크 아웃시 환기.습도 변화에 따른 실내오염물질 저감비교 (Studying indoor contaminant value according to vary ventilation and humidity, when operating bake-out on a new apartment)

  • 조연효;신성우;이지원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.702-707
    • /
    • 2008
  • Improving quality of life and wellbeing of the residential environment and increased interests and importance is growing confidentiality, insulation, high-rise due to a lack of ventilation and indoor air pollution. Several human diseases caused tremendously due to the indoor air which consists of formaldehyde, radon, pollutants such as volatile substances that is called the phenomenon of a new house syndrome. It has become a world-wide issue that the United States, Japan and several other countries of Europe are showing more interests. Furthermore, a lot of damages caused by the syndrome occurs in the new house should be resolved by somehow is urgent. Thus, this study would like to propose the measures based on the whether condition and the way of heating in korea against a new house syndrome via analysis of indoor contaminant Reduction comparison according to vary ventilation and humidity when operating bake-out on a new apartment.

  • PDF