• 제목/요약/키워드: The force of articulation

검색결과 23건 처리시간 0.026초

The Force of Articulation for Three Different Types of Korean Stop Consonants

  • Kim, Hyun-Gi
    • 음성과학
    • /
    • 제11권1호
    • /
    • pp.65-72
    • /
    • 2004
  • The force of articulation is different between voiced and voiceless consonants in the binary opposition system. However, the Korean voiceless stop consonants have a triple opposition system: lenis, aspirated, and glottalized. The aim of this study is to find the primary distinctive feature between the force of articulation and the aspiration for the three different types of Korean stops. Two native speakers of the Seoul dialect participated to this study. The corpus was composed of less than eight syllabic words containing consonants in word-initial position and intervocalic position. Radiocinematography and Mingography were used to analyze the articulatory tension and acoustic characteristics. Korean stops have independent features of articulatory tension and aspiration, in which the indices are different according to position. However, in this system which does not have the opposition of sonority, the force of articulation is the primary distinctive feature and the feature of aspiration is subsidiary.

  • PDF

Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis

  • Qadeer, Sarah;Kerstein, Robert;Kim, Ryan Jin-Yung;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.7-12
    • /
    • 2012
  • PURPOSE. Articulation paper mark size is widely accepted as an indicator of forceful tooth contacts. However, mark size is indicative of contact location and surface area only, and does not quantify occlusal force. The purpose of this study is to determine if a relationship exists between the size of paper marks and the percentage of force applied to the same tooth. MATERIALS AND METHODS. Thirty dentate female subjects intercuspated into articulation paper strips to mark occlusal contacts on their maxillary posterior teeth, followed by taking photographs. Then each subject made a multi-bite digital occlusal force percentage recording. The surface area of the largest and darkest articulation paper mark (n = 240 marks) in each quadrant (n = 60 quadrants) was calculated in photographic pixels, and compared with the force percentage present on the same tooth. RESULTS. Regression analysis shows a bi-variant fit of force % on tooth (P<.05). The correlation coefficient between the mark area and the percentage of force indicated a low positive correlation. The coefficient of determination showed a low causative relationship between mark area and force ($r^2$ = 0.067). The largest paper mark in each quadrant was matched with the most forceful tooth in that same quadrant only 38.3% of time. Only 6 2/3% of mark surface area could be explained by applied occlusal force, while most of the mark area results from other factors unrelated to the applied occlusal force. CONCLUSION. The findings of this study indicate that size of articulation paper mark is an unreliable indicator of applied occlusal force, to guide treatment occlusal adjustments.

풍동실험을 이용한 관절형 컨테이너 크레인의 구조 안정성 해석 (The Structural Stability Analysis of an Articulation Type Container Crane Using Wind Tunnel Test)

  • 이성욱;심재준;한근조;김태형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.838-841
    • /
    • 2005
  • This study was carried out to analyze the effect of wind load on the structural stability of a 50ton articulation type container crane using wind tunnel test and provide a container crane designer with data which can be used in a wind resistance design of an articulation type container crane assuming that a wind load 75m/s wind velocity is applied in an articulation type container crane. Data acquisition conditions for this experiment were established in accordance with the similarity. The scale of an articulation type container crane dimension, wind velocity and time were chosen as 1/200, 1/13.3 and 1/15. And this experiment was implemented in an Eiffel type atmospheric boundary layer wind tunnel with $11.52m^2$ cross-section area. Each directional drag and overturning moment coefficients were investigated and uplift forces at each supporting point due to the wind load were analyzed.

  • PDF

A Reproducible and Reliable Method for Measuring Masseter Muscle Thickness in Maximal Bite Force Using Ultrasonography

  • Hyun-Jeong Park;Sun-Kyoung Yu;Yo-Seob Seo;Ji-Won Ryu
    • Journal of Oral Medicine and Pain
    • /
    • 제47권4호
    • /
    • pp.206-211
    • /
    • 2022
  • Purpose: The purpose of this study is to develop a reproducible and reliable method for evaluating the masseter's functional state by measuring the masseter muscle with ultrasonography (US). Methods: Nineteen healthy adults (9 males, 10 females) were the subjects of this study. During US scanning, the image was taken from the thickest part of the masseter muscle in the image. To evaluate changes in thickness during masseter function, US images were taken of the participant's masseter muscle at rest and during clenching. In this study, US scanning was conducted using two approaches to compare the difference in masseter muscle thickness determined when inducing maximum bite force (MBF). Results: All 19 subjects completed US scanning of the masseter muscle at rest and during clenching under the conventional method and the articulation paper method. There was no difference in masseter muscle thickness measured at rest. However, the thickness of the masseter muscles determined by the articulation paper during jaw clenching was greater than that measured by the conventional method. Conclusions: In conclusion, using the US for masseter muscle evaluation can offer objective and functional information on the masseter muscle. A standardized US scanning method needs to be developed to obtain reproducible and reliable information on the masseter muscle at rest and during clenching. In particular, generating MBF using an articulation paper can be a reproducible and reliable method of measuring the functional state of the masseter muscle.

연결(連結) 차량(車輛)의 재크나이프 현상에 영향(影響)을 미치는 인자(因子)인자에 대한 연구 (A Study on the Factors that Influence Jack Knife Phenomenon of Articulated Vehicles)

  • 강대민;안승모
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.58-63
    • /
    • 2007
  • Vehicular safety and occupant injury have been of considerable interest to the public. The dynamic response of an articulated vehicle is different from that of single body vehicle due to its geometric and inertia properties. Articulated vehicles have the tendency to jackknife if they lose driving safety. Influence of factors for driving safety of an articulated vehicle(Tractor-Semitrailers) has been analysed by the EDVTS, a kinetic analysis program for an articulated vehicle. EDVTS permits an analyst to investigate the effect of many variables in a short period of time, and enables to obtain an accurate explanation of driving safety. The factors used in the analysis include the load, friction coefficient, tire flat, increase of braking force, and trailer geometry. Based on the results, the articulation angle and driving safety were influenced remarkably by the load, coefficient of friction, increase of braking force. However, trailer geometry, such as length and width, did not affect articulation angle and driving safety

  • PDF

풍하중이 관절형 붐을 가진 컨테이너 크레인의 구조 안정성에 미치는 영향 분석 (The Analysis of the Effect of .Wind Load on the Structural Stability of an Articulation type Container Crane)

  • 이정명;이성욱;한동섭;한근조
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2005년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2005
  • 관절형 컨테이너 크레인은 계류 시 Boom이 ㄱ자 형태인 크레인을 말한다. 즉, 계류 시 Inner Boom은 거의 수직이고, Outer Boom은 거의 수평이다. 이 크레인은 보통의 컨테이너 크레인과는 달리 주변 환경의 원인으로 인해 컨테이너 크레인의 고도가 제한될 경우에 사용된다. 관절형 컨테이너 크레인의 높이는 계류 시 70m에 달하기 때문에 바람에 매우 큰 영향을 받게 된다. 이에 따라 풍하중이 컨테이너 크레인에 미치는 영향에 대한 연구의 필요성이 증대되고 있다. 따라서 본 연구에서는 풍하중이 작용할 때, 풍하중의 작용 방향에 따라 컨테이너 크레인의 각 지지점에서 발생하는 반력 분포와 기계실의 위치변화가 관절형 컨테이너의 구조 안정성에 미치는 영향을 유한요소해석을 통해 분석하였다.

  • PDF

르 꼬르뷔제 작품에 나타나는 건축과 대지의 분리 관계 연구 - 퓨리즘 회화의 분석을 바탕으로 - (A Study on the Articulation between Architecture and Site of Le Corbusier's Works - Based on the Analysis of Purism Painting -)

  • 조주현;신범식
    • 한국실내디자인학회논문집
    • /
    • 제21권3호
    • /
    • pp.40-49
    • /
    • 2012
  • The purpose of this study is to look into an articulation between architecture and site of Le Corbusier's works. The first of his principals, "piloti" shown in "5 principals in new architecture" represents the articulated relationship between architecture and site. It certainly works as a driving force of new architecture Le Corbusier pursued. The study presumed that this is the constructive application of "Modernity" with new technology and materials during the turn of century. It also seems to be a tool for visual presentation of implied "Will of Form" for his paintings and architecture as well. In this perspective, this study suggests an assumption of a certain connection between the principal of spatial articulation on his purism paintings and the architectural spaces created by piloti. The study finds evidences that supports the above mentioned assumption; first, the inter-relationship between the interval spaces on his paintings and lifted box, second, the movement of space as overlapped spaces, and finally, overlapped volume which is represented by intersection.

  • PDF

추나요법을 적용한 체위성 상완신경총 손상 치험 1례 (A Clinical Case Study on Postural Brachial Plexus Injury with Whole Body Articulation-Mechanics Technique)

  • 장동호;강연경;조성우;이영석
    • 척추신경추나의학회지
    • /
    • 제5권2호
    • /
    • pp.49-55
    • /
    • 2010
  • This study was performed to report the effect of oriental medical treatment and general biomechanic manipulation on a patient with upper limb palsy caused by postural brachial plexus injury. The patient was treated with acupuncture, herb medicine and general biomechanic manipulation. The effectiveness of treatment was evaluated with range of motion, visual analogue scale and manual muscle test. After 11 times treatment, motion and muscular force were progressed, pain was decreased. This result suggests that oriental medical treatment and general coordinative manipulation are effective to care the postural brachial plexus injury.

  • PDF

An instrumented glove for grasp specification in virtual reality based point-and-direct telerobotics

  • Yun, Myung Hwan;Cannon, David;Freivalds, Andris
    • 대한인간공학회지
    • /
    • 제15권2호
    • /
    • pp.165-176
    • /
    • 1996
  • Hand posture and force, which define aspects of the way an object is grasped, are features of robotic manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system is being used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct (VR-PAD) robotics implementation. In the Computer Integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with FSR (Force Sensitive Resistor) pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufactruing, space operations and other flexible robotics applications. In each case, the VR-PAD approach improved the computational and delay problems of real-time multiple- degree-of-freedom force feedback telemanipulation.

  • PDF

An instrumented Glove for Grasp specification in virtual reality based point-and-direct telerobotics

  • Yun, Myung-Hwan;Cannon, David;Freivalds, Andris
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1996년도 춘계공동학술대회논문집; 공군사관학교, 청주; 26-27 Apr. 1996
    • /
    • pp.141-146
    • /
    • 1996
  • Hand posture and force, which define aspects of the way an object is grasped, are features of robotics manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system is being used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct(VR-PAD) robotics implementation. In the Computer Integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with FSR (Force Sensitive Resistor) pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufacturing, space operations and other flexible robotics applications. In each case, the VR-PAD approach improved the computational and delay problems of real-time multiple-degree-of-freedom force feedback telemanipulation.ck telemanipulation.

  • PDF