• Title/Summary/Keyword: The first leak time

Search Result 35, Processing Time 0.026 seconds

Assessment of Bacteria Removal Using Silver Ion Absorbed Ceramic Filter

  • Kim, Woo-Hang;Smith, James
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.901-907
    • /
    • 2012
  • The objective of this study was to evaluate bacteria removal ability of the metallic silver which was baked silver ion impregnated ceramic filter at heating condition. Silver leaking from baked ceramic filter was tested to sustain bacteria removal for a long time. Silver impregnated ceramic filter could remove E. coli completely at $10^{12}$ MPN/100ml to $10^{13}$ MPN/100ml of influent. However, ceramic filter without silver did not remove E. coli completely under the same condition. After baking, the silver impregnated ceramic filter almost didn't leak out the silver ion from filter. Photo of TEM (Transmission Electron Microscopy) showed that absorbed silver ions remained in ceramic filter after baking process and most of silver were less than 10 nm. According to the increase in the amount of silver in the ceramic filter, removal efficiencies of E. coli were increased but turbidity removal was decreased. It can be accounted that increased removal efficiency of E. coli was from disinfection of silver that is in the ceramic filter. Simulated concentrations of bacteria agree well with the observed experimental effluent concentration data. Moreover, first-order decay coefficients increased to 0.0034/min after silver was added in the ceramic filter. Increase of first-order decay coefficient proves that silver-added ceramic filter can remove bacteria easily.

A Secure Authentication Method for Smart Phone based on User's Behaviour and Habits

  • Lee, Geum-Boon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.65-71
    • /
    • 2017
  • This paper proposes a smart phone authentication method based on user's behavior and habit that is an authentication method against shoulder surfing attack and brute force attack. As smart phones evolve not only storage of personal data but also a key means of financial services, the importance of personal information security in smart phones is growing. When user authentication of smart phone, pattern authentication method is simple to use and memorize, but it is prone to leak and vulnerable to attack. Using the features of the smart phone pattern method of the user, the pressure applied when touching the touch pad with the finger, the size of the area touching the finger, and the time of completing the pattern are used as feature vectors and applied to user authentication security. First, a smart phone user models and stores three parameter values as prototypes for each section of the pattern. Then, when a new authentication request is made, the feature vector of the input pattern is obtained and compared with the stored model to decide whether to approve the access to the smart phone. The experimental results confirm that the proposed technique shows a robust authentication security using subjective data of smart phone user based on habits and behaviors.

A study of a combined release model using perturbation solutions (섭동해를 이용한 혼합 누출에 관한 연구)

  • Kim, Myungbae
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.41-48
    • /
    • 2014
  • Leak of liquid has been categorized conventionally into instantaneous release and continuous release. In this study, the spread of cryogenic liquid due to limited period of release is investigated for the first time to establish a new classification method with recognizing the irrationality of the conventional one. Such physical phenomena are governed by simultaneous equations concerning volume, radius and height of pool of the cryogenic liquid, and major parameters are evaporation rate per unit area, time of release, and spill quantity. The simultaneous governing equations is decoupled to get efficiently perturbation solutions. As the results, for the same spill quantity, in view of release model, combined release model that consists of continuous and consecutive instantaneous model is necessary with small time of release, while continuous model is solely required with large time of release. Also, the combined model is necessary for small spill quantity with the same time of release. These two regimes of release are clearly distinguished using the perturbation solution to provide a clear basis for the new classification of release models.

A Study on Robustness Improvement of the Semiconductor Transmitter and Receiver Module By the Bias Sequencing and Tuning the Switching Time (바이어스 시퀀스와 스위칭 타임 튜닝을 통한 반도체 송수신 모듈의 강건성 향상에 대한 연구)

  • Yoo, Woo-Sung;Keum, Jong-Ju;Kim, Do-Yeol;Han, Sung
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.251-259
    • /
    • 2016
  • This paper describes that how to enhance the robustness of semiconductor TRM(Transmitter and Receiver Module) through the bias sequencing and tuning the switching time. Previous circuit designs focused on improving the MDS(Minimum Detection Signal) performance. Because TRM has critical problem which transmission output signal leak into receiver by it's compact design. Under this condition, TRM was frequently broken down within the MTBF(Mean Time Between Failure). This study proposes the bias sequencing and tuning the switching time to improve above problem. At first, we collected major failure symptom and infer it's cause. Second, we demonstrated it's effect by derive the improvement method and apply it to our system. And finally we can convinced that the proposed method clear the frequent failure problem with its lack of isolation.

Report on Extended Leak-Off Test Conducted During Drilling Large Diameter Borehole (국내 대구경 시추공 굴진 중 Extended Leak-Off Test 수행 사례 보고)

  • Jo, Yeonguk;Song, Yoonho;Park, Sehyeok;Kim, Myung Sun;Park, In-Hwa;Lee, Changhyun
    • Tunnel and Underground Space
    • /
    • v.32 no.5
    • /
    • pp.285-297
    • /
    • 2022
  • We report results of Extended Leak-Off Test (XLOT) conducted in a large diameter borehole, which is drilled for installation of deep borehole geophysical monitoring system to monitor micro-earthquakes and fault behavior of major fault zones in the southeastern Korean Peninsula. The borehole was planned to secure a final diameter of 200 mm (or more) at a depth of ~1 km, with 12" diameter wellbore to intermediate depths, and 7-7/8" (~200 mm) to the bottom hole depth. We drilled first the 12" borehole to approximately 504 m deep and installed American Petroleum Institute standard 8-5/8" casing, then annulus between the casing and bedrock was fully cemented. XLOT was carried out for several purposes such as confirming casing and cementing integrity, measuring rock stress states. To that end, we drilled additional 4 m long open hole interval to directly inject water and pressurize into the rock mass using the upper API casings. During the XLOT, flow rates and interval pressures were recorded in real time. Based on the logs we tried to analyze hydraulic conductivity of the test interval.

Model-Based Detection of Pipe Leakage at Joints (모델 기반 파이프 연결부 누수 감지 시스템)

  • Kim, Taejin;Youn, Byeng D.;Woo, Sihyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.347-352
    • /
    • 2015
  • Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found.

Parametric Study of AC Current Lead for the Termination of HTS Power Cable

  • Kim, D.L;Kim, S.H.;S. Cho;H.S. Yang;Kim, D.H.;H.S. Ryoo;K.C. Seong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.107-110
    • /
    • 2003
  • High Temperature Superconductor (HTS) transmission cable can carry more than 2 to 5 times higher electricity and also obtain substantially lower transmission losses than conventional cables. Liquid nitrogen is to be used to cool the HTS power cable and its cost is much cheaper than the liquid helium used for the cooling of metal superconducting wire. In Korea the HTS power cable development project has been ongoing since July, 2001 with the basic specifications of 22.9kV, 50MVA and told dielectric type as the first 3-year stage. The cryogenic system of the HTS cable is composed of HTS cable cryostat termination and refrigeration system. Termination of HTS cable is a connecting part between copper electrical cable at room temperature and HTS cable at liquid nitrogen temperature. In order to design the termination cryostat, it is required that the conduction heat leak and Joule heating on the current lead be reduced, the cryostat be insulated electrically and good vacuum insulation be maintained during long time operation. Heat loads calculations on the copper current lead have been performed by analytical and numerical method and the feasibility study fer the other candidate materials has also been executed.

A study on the application and counter measures of IC tag in international marine container transport (국제해상컨테이너운송에서 보안강화를 위한 전자태그(IC tag)의 적용과 대응방안)

  • Han, Sang-Hyun;Choi, Jun-Ho
    • International Commerce and Information Review
    • /
    • v.12 no.2
    • /
    • pp.133-158
    • /
    • 2010
  • Since 11 September 2001, the awareness of terrorists' actions has clearly risen. The potential threat of terrorists using containers poses a large risk to our economies and to our societies. In order to protect cargo from damage and terrorist threats, business and government turn to RFID and IC tags, and tradition container is replaced by IC smart container. In this study, presented application of IC tag and future tasks to Container transport by sea in viewpoint of security strengthening. First, realization and international SCM realization structural order that cover container supply chain whole of international standardization and association between industry are certainly needed. Second, it may have to try in technical development for IC tag Ratio that can read elevation moment develop suitable IC tag or reader in International Standard. Third, Need to establish concrete use policy as soon as possible in national dimension at the same time effort for international standard normalization of frequency. Finally, it shows to uses jointly with electron sealing and must solve problem about usable plan and information leak.

  • PDF

TCP/IP Using Minimal Resources in IoT Systems

  • Lee, Seung-Chul;Shin, Dongha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.10
    • /
    • pp.125-133
    • /
    • 2020
  • In this paper, we design 4-layer TCP/IP that utilizes minimal memory and processor resources in Internet of Things(IoT) systems. The TCP/IP designed in this paper has the following characteristics. First, memory resource is minimized by using minimal memory allocation. Second, processor resource is minimized by using minimal memory copy. Third, the execution time of the TCP/IP can be completed in a deterministic time. Fourth, there is no memory leak problem. The standard in minimal resources for memory and processor derived in this paper can be used to check whether the network subsystems of the already implemented IoT systems are efficiently implemented. As the result of measuring the amount of memory allocation and copy of the network subsystem of Zephyr, an open source IoT kernel recently released by the Linux Foundation, we found that it was bigger than the standard in minimal resources derived in this paper. The network subsystem of Zephyr was improved according to the design proposed in this paper, confirming that the amount of memory allocation and copy were decreased by about 39% and 67%, respectively, and the execution time was also reduced by about 28%.

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.