• 제목/요약/키워드: The fire safety

검색결과 3,669건 처리시간 0.032초

외부화염에 의해 단락된 비닐코드 및 고무코드의 화재 패턴 (The fire patterns of vinyl and rubber cords shorted by external flame)

  • 김동우;송길목;김동욱;김영석;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 2004
  • The electrical fire frequently happens through carelessness of a vinyl and rubber cords such as a poor contact, a mechanical stress and so on. Electrical fire occupies the greater part(about 30%) of all fires in Korea. In this paper, we compared to the fire dispersive patterns of vinyl and rubber cords according to the external flame in the wall-model. The fire progress and dispersive patterns were measured by a high speed imaging system(HG-100K, REDLAKE, USA). From the results, short-circuit of the vinyl cords are easy to happen than the rubber cords by the external flame. The pattern of fire was progressed a flashover, scattering and disconnection. The fire progress on the vinyl cord is not observed because the ignition energy decreases. However, the fire was progressed continuously on the rubber cord.

  • PDF

부사관학과 학생들의 소방안전교육 경험과 생활안전의식에 관한 연구 (Research for the Experience of Fire Fighting Aafety Education and Living Safety Consciousness of Department of Noncommissioned Officer in College Students)

  • 이원주;권신영;강순형;나윤채
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.159-167
    • /
    • 2015
  • The main purpose of this study is to evaluate the awareness survey on the experience of fire fighting safety education and living safety consciousness of college students in the department of noncommissioned officer. Additionally, making provision of basic references and the effective fire fighting safety education is another important purpose of this study. In order to evaluate the awareness, the survey consist of 43 queries based on 6 queries for general characters, 9 queries for experiences of fire fighting safety education and 30 queries for living safety consciousness. The collected data from survey was analyzed using SPSS 20.0 win program. The interrelationship for general characters was confirmed using analysis of frequency, percentage, independent T-tset, ANONVA analysis, and regression analysis. The results show that the experience of fire fighting safety education and living safety consciousness of students from the combatant branch and ordnance corps are higher than those students from quartermaster corps. This may be attributed to the presence or absence of safety relevant courses on a curriculum. Therefore, the presence of safety courses on a curriculum should be one of important points for improving the experience of fire fighting safety education and living safety consciousness of these college students.

소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구 (A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System)

  • 진승현;김혜원;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

FDS를 이용한 실내화재 모사의 문제점 II. 벽면형 및 모서리형 화재 (A Numerical Study of a Room Fire for Fire Sizes II. wall fire and corner fire)

  • 고경찬;박외철
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.9-13
    • /
    • 2004
  • To confirm the previous finding that FDS predicts a fire growth rate too rapid compared with an experiment in a center fire in a room with an opening, the same computational fluid dynamics was applied to two types of fires, wall fire and comer fire. First the grid size was chosen to eliminate possible numerical errors due to a coarse grid system. Then the two types of fires were simulated for three different fire sizes, 7.65, 21.25, and 51.57kW for each type, which are the same as in the experiment to be compared with. The fires were predicted to grow too fist although the average temperatures and heights of the neutral planes were in good agreement with measurement.

아파트 거주자의 안전교육 만족도와 소방계획서의 활용성이 화재안전의식에 미치는 영향 (The Effect of Safety Education Satisfaction of Apartment Residents and Application of Fire Protection Plan on Fire Safety Awareness)

  • 김상식;공하성
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.103-114
    • /
    • 2020
  • 이 연구는 아파트 거주자의 안전교육 만족도와 소방계획서의 활용성이 화재안전의식에 미치는 영향을 규명하는데 주된 목적이 있다. 분석 결과는 다음과 같다. 첫째, 안전교육내용의 만족도가 낮으며 화재안전의식수준에 부(-)의 영향을 미쳤다. 이는 아파트 거주자의 안전교육내용의 흥미나 참여가 낮을수록 화재안전의식에도 영향을 미쳐 화재로부터 안전성 확보에 대처하지 못하는 것으로 관리 주체에서는 안전교육의 만족 및 안전문화의 정착을 위해 학습지원 정보시스템 등으로 교육의 만족도에 긍정적인 영향이 필요할 것으로 판단된다. 둘째, 소방계획서의 활용성이 화재안전의식에 정(+)의 영향을 미쳤다. 이러한 결과는 아파트 거주자는 안전에 필요한 교육 및 훈련에 접근하는 기회가 없을 뿐 아니라 의무적으로 수료하는 법적인 책임감이 없어 화재안전의식이 부족하므로 관리 주체에서 소방계획서에 의한 운영강화 및 활성화로 거주자의 참여나 화재안전의식을 고취해 화재로부터 안전한 주거 생활이 되도록 대처하여야 할 것이다. 셋째, 아파트 거주자의 안전교육 만족이 화재안전의식에 미치는 영향에 대해 소방계획서의 활용성은 조절효과가 나타났다. 이는 안전교육 만족도가 높아지면 화재안전의식도 높았지만, 아파트 거주자와 관리주체의 직원이 일체가 되어 소방계획서에 의한 업무를 시행하고 참여가 높을 때 화재안전의식에도 긍정적인 효과로 나타나므로 소방계획서의 운영과 안전교육 만족도가 높을수록 화재안전의식도 높아져 주거 생활에 영향력이 높아짐을 보여준다.

원전 케이블 화재 열속평가 및 열화 진단방법에 관한 연구 (A Study on Heat-Flux Evaluation for Cable Fire Including Diagnostic Methodology for Degradation in Nuclear Power Plants)

  • 임혁순;김두현
    • 한국안전학회지
    • /
    • 제26권2호
    • /
    • pp.20-25
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments. The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a multi-core cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the characteristic of cable fire is investigated and the heat-flux evaluation for cable fire is studied. Moreover, a diagnostic methodology for degraded cable in nuclear power plants is presented.

작업분류체계 기반 소방 객체 IFC 정보 모델링 확장 방안 연구 (Extension of IFC information Modeling for Fire Safety based on WBS)

  • 원정혜;김태훈;추승연
    • 한국BIM학회 논문집
    • /
    • 제13권2호
    • /
    • pp.37-46
    • /
    • 2023
  • The main objective of this study is to propose a method to enhance building safety using the Industry Foundation Classes (IFC) schema in Building Information Modeling (BIM). To achieve this goal, a fire object relationship diagram is created by using the Model View Definition (MVD) and Property Set (Pset) methodology, as well as the Work Breakdown Structure (WBS) based object relationship analysis. The proposed method illustrates how to represent objects and tasks related to fire prevention and human safety during a building fire, including variables that are relevant to these aspects. Furthermore, the proposed method offers the advantage of considering both the IFC object hierarchy and the project work hierarchy when creating new objects, thereby expanding the attribute information for fire safety and maintenance. However, upon confirmation via an IFC viewer after development, a problem with the accuracy of mapping between attributes and objects arises due to the issue of proxy representation of related object information and newly added object information in standard IFC. Therefore, in future research, a mapping method for fire safety objects will be developed to ensure accurate representation, and the scope of utilization of the fire safety object diagram will be expanded. Furthermore, efforts will be made to enhance the accuracy of object and task representation. This research is expected to contribute significantly to the technological development of building safety and fire facility design in the future.

초고층 건축물 소방안전관리의 기본방향에 관한 연구 (High-rise buildings in the general direction of the Fire Safety Management Study)

  • 최만철;김병석
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 춘계학술대회
    • /
    • pp.79-93
    • /
    • 2011
  • Unlike a general building high-rise buildings itself has a kind of risk. In this study, the risk of a number of high-rise buildings have fire safety management of the particular risks associated with looking for ways to minimize focused. Theoretical Study of the United States since the collapse of the WTC buildings, and be the center of the authentic country was. outside of the high-rise building fire safety and related issues, and measures were based on the theory of reference. Issues include voluntary arson. disaster management, building codes and fire regulations of the discrepancies, such as fire safety aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high-rise buildings. Although differences of opinion between departments will not be easy to fire and building regulations regarding conflicts of laws among other things, require immediate resolution, and high-rise buildings to create a standard for effective crisis management manual countermeasures will also be ensured.

  • PDF

사례 분석을 통한 IoT 기반 화재탐지시스템의 화재 감지신호 특성 (A Case Study of the Characteristics of Fire-Detection Signals of IoT-based Fire-Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권3호
    • /
    • pp.16-23
    • /
    • 2022
  • This study aims to provide a fundamental material for identifying fire and no-fire signals using the detection signal characteristics of IoT-based fire-detection systems. Unlike analog automatic fire-detection equipment, IoT-based fire-detection systems employ wireless digital communication and are connected to a server. If a detection signal exceeds a threshold value, the measured values are saved to a server within seconds. This study was conducted with the detection data saved from seven fire accidents that took place in traditional markets from 2020 to 2021, in addition to 233 fire alarm data that have been saved in the K institute from 2016 to 2020. The saved values demonstrated variable and continuous VC-Signals. Additionally, we discovered that the detection signals of two fire accidents in the K institution had a VC-Signal. In the 233 fire alarms that took place over the span of 5 years, 31% of smoke alarms and 30% of temperature alarms demonstrated a VC-Signal. Therefore, if we selectively recognize VC-Signals as fire signals, we can reduce about 70% of false alarms.

원자력발전소의 화재사건 확률론적안전성평가 모델 구축에 관한 연구 (A Study on the Constructions of Fire Events Probabilistic Safety Assessment Model for Nuclear Power Plants)

  • 강대일;김길유
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.187-194
    • /
    • 2016
  • A single fire event within a fire area can cause multiple initiating events considered in internal events probabilistic safety assessment (PSA). For an example, a fire event in turbine building fire area can cause a loss of the main feed-water and loss of off-site power initiating events. This fire initiating event could result in special plant responses beyond the scope of the internal events PSA model. One approach to address a fire initiating event is to develop a specific fire event tree. However, the development of a specific fire event tree is difficult since the number of fire event trees may be several hundreds or more. Thus, internal fire events PSA model has been generally constructed by modifications of the pre-developed internal events PSA model. New accident sequence logics not covered in the internal events PSA model are separately developed to incorporate them into the fire PSA model. Recently, many fire PSA models have fire induced initiating event fault trees not shown in an internal event PSA model. Up to now, there has been no analytical comparative study on the constructions of fire events PSA model using internal events PSA model with and without fault trees of initiating events. In this study, the changing process of internal events PSA model to fire events PSA model is analytically presented and discussed.