• Title/Summary/Keyword: The fire safety

Search Result 3,686, Processing Time 0.033 seconds

Cost-Benefit Analysis of Electrical Safety Speed-call Service Using Electrical Fire Statistics Analysis and Outcome Analysis Logic Model (전기화재 통계 및 성과 분석 모델을 이용한 전기안전 긴급출동 고충처리 서비스의 비용 편익 분석)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1943-1947
    • /
    • 2016
  • Korea Electrical Safety Cooperation(KESCO) have provided the electrical safety speed-call service from 2007 year. Purpose of the service is to reduce discomfort of electricity use and to prevent electrical accident like as electrical fire and shock accident by providing emergency treatment service on fault of the residential electrical facilities notified in the specific house like as a lower-income group and a social welfare facility. But efficiency and economic evaluation of the electrical safety speed-call service is impossible because analysis on the quantitative effect of the service is difficult. This paper presents cost-benefit analysis method and result of the electrical safety speed-call service. The presented cost-benefit analysis method has a two-step process: the first step is to measure quantitative electrical fire prevention effect of the service by using electrical accident statistics and developing outcome analysis logic model of the service effect, and the second step is to analysis cost-benefit(B/C)of the service by calculating quantitative benefit analysis on the measured quantitative electrical fire prevention effect. The results showed that cost-benefit(B/C)of the electrical safety speed-call service is over 4 after 2010 year.

An Experimental Study on the Behavior of Liquid Fuel Flames in the Confined Space (밀폐공간에서 액체연료 화염의 거동에 관한 실험적 연구)

  • Jeon, Kil Song;Hwang, Ji Hyun;Lee, Tea Won
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.87-93
    • /
    • 2021
  • Modern society shows rapid growth that is different from that of the development of existing technologies. The development of these technologies has led to the tendency of buildings to become dense, large and advancing. Regarding fire hazards, the possibility of large-scale fires causing fatal damage, due to the rapid spread of fire, increases. Therefore, for this reason, fire defense, i.e. detection and fire extinguishing facilities, in buildings are essential and well applied. But there are always limitations to that. Based on this reason, we would like to suggest the introduction of a new concept of a fire safety system. The method presented here is not only to use a single system for fire detection and fire extinguishing systems but to jointly use it in the environment and energy management fields within the building. However, an important step is required before introducing a system of these technologies. The fire extinguishing method proposed by this system is a method of extinguishing by blocking oxygen flowing into the space where the fire occurred. However, a sufficient basis is needed for this system to be applied in practice. Therefore, in this study, we intend to conduct a preliminary experiment to introduce the new concept of fire detection and extinguishing. The experiment used ethanol with a relatively simple combustion reaction and a high possibility of complete combustion. As a result, it was confirmed how the internal values changed during a fire using ethanol. Resultingly, we obtained the internal oxygen concentration and internal environmental changes according to the initial flame size. Lastly, the data accumulated in this study can be used as data for application in an automatic fire extinguishing system.

Study on the Management and Improvement Methods of Fire Safety Shared Tax (소방안전교부세의 운영 및 개선방안에 관한 연구)

  • Jang, Jung-Don;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.117-125
    • /
    • 2018
  • This paper examined the problems concerning recognition of business selection and operation, etc. and the presentation of the corresponding improvement measures. For this purpose, according to the results of a questionnaire survey on recognition of detailed business operation of the fire safety shared tax, satisfaction in business execution, financial operation measures for the subject of fire fighters, fire fighters have been shown to be indifferent to the detailed business field of fire safety shared tax, investment contents, etc. in the operation of fire safety shared tax. In terms of satisfaction after execution of the shared tax, reduction of the aging rates for firefighting equipment and improvement of dissemination rate was shown to be high with Fire Sergeant (M = 3.70) and a service duration of more than 16 years (M=3.64). To improve the measures of finance, there was considerable feedback saying that the reduction in state subsidy was inappropriate. In view of the diversification and development of the fire safety shared tax businesses being operated on a limited basis along with the overlap of most state subsidy businesses with safety field businesses, legal system improvement is needed for the stable securing of insufficient firefighting financial resources so that the full amount of shared tax can be invested in firefighting fields.

A Study on Real Condition Estimation for Fire Protection Safety Management System Builds (소방안전경영시스템 구축을 위한 실태평가에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.18-24
    • /
    • 2013
  • Goverment and enterprises have been devoting a lot of dffort in order to prevent the loss of human and property due to a large, diversified fire, explosion, global warming and disasters caused by natural phenomena. But Enterprises came forward and running in the economy priority policy for profit-seeking until now in order to meet the macro purpose of quality improvement of national life and welfare promotion in company with National growth, as a result of lax risk management have had to endure the loss of precious lives and property. According to the '2007 Survey of public safety for the activation of the safety culture' of National Emergency Management Agency [NEMA], a insensitivity of safety in our society was surveyed 'a serious level'. In this study, surveyed need of 'step-by-step fire protection safety management system builds' in order to prevent fire safety accident and improvement of safety awareness level through a systematic management and real condition estimation of not only large business that can control risk management, but also small business that has a big risk to occur accident easily according to small budget and organization.

Accomplishment Analysis of the Fire Fighting and Safety Research Development Program Supported by Ministry of Public Safety and Security (2012-2014) (국민안전처 소방안전분야 연구개발사업(2012년~2014년)의 성과분석)

  • Chung, Jae-Han;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.141-147
    • /
    • 2016
  • The fire fighting and safety research development program supported by Ministry of Public Safety and Security is composed of fire prevention and alert technology research, special disaster response technology research, and rescue and disaster-field response safety technology research. The principal accomplishment indices of this research program are (1) patent submitting or registration; (2) field test, ensuring performance criteria for commercialization, development of prototype, registration of software, royalty of technology-transfer; (3) the task to be carried out in a published research paper, and number of applied policies; and (4) the study period of task performance of employment and incubated high-technology manpower. Therefore, this study analyzed the performance result of a patent, research paper, and software registration of the fire-fighting and safety R&D program supported by Ministry of Public Safety and Security from 2012 to 2014.

A Study on Improvement of Safety Management System of Publicly Used Establishments Through Analysis of the UK Regulatory Regime (영국 안전규제체계의 분석을 통한 국내 다중이용업소 안전관리체계의 개선방안 연구)

  • Park, Suhyeong;Yoon, Myong-O
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.768-783
    • /
    • 2020
  • Purpose: In response to the critical risk of fire due to the characteristic of Publicly used establishments(hereinafter referred to as PUE), 'Special Act on the Safety Control of PUE' was enacted in 2006 and is still in operation. However, in spite of numerous revisions so far, still there are problems to be resolved. This study analyses the regulatory regime of fire safety in UK to find measures which could fundamentally improve the safety management of PUE. Method: This study compares and analyses the safety management system of PUE in Korea and the case of the UK by using the comparative research method. Result: As a result of the qualitative analysis, some noticeable systems and concepts of the UK regulatory regime have been discovered(e.g. 'Responsible person', 'Fire risk assessment', 'Fire safety audit', etc.) and consequently, 'Proposal for the Fire Safety Management System for PUE' is designed based on the findings from examples in the UK and drawbacks of safety management of PUE. Conclusion: This study proposes the way to improve the safety management of PUE into a more rational and effective system by analysing the case of the UK, which reorganised the fire safety management to the private sector centered, in which the fire authority minimizes intervention.

A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities (폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구)

  • Lee, Jae-Young;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

A Study on the Analysis and Application of the Fire Simulation Tools for Ships (선박화재 시뮬레이션을 위한 도구 분석과 적용에 관한 연구)

  • Choi, Jin;Lee, Dong-Kon;Park, Beom-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.2 s.152
    • /
    • pp.83-92
    • /
    • 2007
  • To improve the fire safety of ships, it is required to prepare the systematic design guideline for fire protection and the way of assessing fire characteristics quantitatively. The introduction of simulation technique based on fire engineering is useful to assess fire safety performance quantitatively. Fire simulation tools are currently developing with U.S.A., Europe and Japan as a leader. Most of current fire simulation tools were developed for building or inland structure. Therefore it is required validation process and development of data base to apply maritime environments. In this paper, I/O parameters of simulation tools such as CFAST and BRI2002 of zone model and FDS and KFX of field model analysed, and designed data base considering maritime environment. The fire simulation for the pool fire model of engine room and its adjacent compartments is performed and evaluated the results.

A Study of Prevention Management System Model and Fire Safety Diagnose for Cultural Heritages -Based on Traditional wooden structure in kyong gi-Do- (중요문화재의 소방안전 진단 및 예방관리 시스템 모델 연구 -경기도내 전통적인 목조건축물 중심으로-)

  • 정길흥
    • Journal of the Korean Professional Engineers Association
    • /
    • v.32 no.6
    • /
    • pp.148-157
    • /
    • 1999
  • As cultural Heritages are source of the national history and a life transition, their extinction is a fatal shock as result of cutoff the genealogy of the creative national spirit. So, we have necessarily to protect them, and to get the duty and the responsibility which the cultural inheritance hands over tnem to descendants with preserving and meaning safely at present time. In these days, the risk of fire in the Cultural Heritages building is increased because of rash changing environments from the indiscreet development of them. Accordingly, in order to get the original transmission of the Cultural Heritages, this paper involves being intensive the fire safety information of the Cultural Heritage in kyonggi-do province, analyzing their diagnoses, and studying a Fire Safety Prevention Management model to protect and to maintain them continuously. Therefore, it is to contribute from this approach to collecting fire safety information, analyzing diagnostic problems in fire accidents, and to manage the prevention method for protecting and maintaining the Cultural Heritages.

  • PDF

A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building - (우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 -)

  • Lee, Se-Myong;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-41
    • /
    • 2011
  • Regulation of Escape and fire-prevention of Building of South Korea were enacted as a part of building codes in 1962. Since it was enacted, the law has gone through many changes. In this study, evaluated the fire safety of the law about the case of a hotel that the fire risk are expected to be higher whenever it was changed. As a result, the current law has gotten better in tire safety since it was enacted. However, especially it could be confirmed that the evacuation safety is insufficient in the lower level of hotel building. In the case of accommodation, because the occupants become aware of fire lately, they have not enough time to escape. Therefore, this study suggests that it is needed to come up with an effective counterplan about the interior finish materials, fire door and fire compartments that the smoke layer descending time is longer.