• Title/Summary/Keyword: The causes of fire

Search Result 502, Processing Time 0.03 seconds

Study on the Surface Temperature and Fire Protective Thickness for Structural Steel Elements at Fire Conditions (강구조 부재의 표면온도 산정 및 내화피복두께에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.55-61
    • /
    • 2010
  • Fire resistance is very essential for all buildings to save peoples who live within buildings or use and to protect the properties when the buildings are covered with fire. The fire resistance were evaluated by loading or nonloading fire tests which are known very expensive and require lots of time. That causes the lacks of research activities and there are only small cases of fire resistance. The purposes of this paper are to analyze the temperature analysis for various structural elements such as columns and beams those are can be applied to buildings and to suggest the resonable fire protective thickness of concrete slab according to the required fire resistance time.

A Study on the Possibility of Electrical Fires due to the Short Circuit and Ground Fault of Power Cable Supported by an Iron Fence (철제펜스로 지지된 동력배선의 단락.지락에 의한 전기화재 발생 개연성 연구)

  • Kim, Jeong-Hun;Park, Byoung-Ki;Song, Jong-Hyeok;Jung, Ki-Chang
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.41-45
    • /
    • 2007
  • Short circuit and ground fault account for the primary causes of electrical fires. In this research, real-scale experiments were conducted to assess the possibility of electrical fires due to these causes. The experiment conditions were identical with an actual fire accident, in which the power cable was supported by an iron fence. The purposes of this research are to investigate the short circuit caused by wire cutting, the conductivity of the iron fence depending on its coating conditions, and the ground fault of one wire or two wires in an effort to reconstruct the fire accident. The test results show that, owing to the instant operation of circuit breaker in the moment of short circuit or ground fault, the generated ignition energy is far less than necessary to start an ignition. Therefore it is concluded that electrical fire is highly unlikely if the electric system is protected by a circuit breaker with normal functions.

An Experimental Investigation on Combustion Characteristics of the Knockdown Building (조립식 건축물의 화재특성연구)

  • Lee, Jung-Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.30-35
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2$, $CO_2$, CO, $NO_x,$, $SO_x$, HCI, HCN were measured, in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

Analysis of Car Fire Cases Related to a Lithium Battery and Cause Investigation Technique (리튬배터리와 관련된 차량화재 사례 및 원인조사 기법 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.98-106
    • /
    • 2019
  • As lithium batteries have been used for car navigation systems and as the second battery for black boxes, lithium battery-related car fires have often occurred. In the case a lithium battery is the fire origin, a fire investigation technique has not been established to determine if a battery ignites or whether the lithium battery is damaged by fire. This study introduced car fire cases related to lithium batteries, analyzed the causes of a fire of a lithium battery, and proposed fire investigation techniques to objectively determine if a lithium battery ignites or whether a lithium battery is damaged by fire after external ignition.

Study on the influence of life-style on infertility (불임(不姙)과 생활습관의 상관성에 대한 연구)

  • Bang, Jung-Kyun
    • The Journal of Korean Medical History
    • /
    • v.18 no.1
    • /
    • pp.3-14
    • /
    • 2005
  • Among modern people's life-style, the lack of exercise and sleep is related to infertility. Underexercise accumulates damp-sputum, resulting in the insufficiency of essence. It also obstructs the creation of essence, leading to insufficient essence. Activities at night without sleep cannot create the condition to help the process of yin, causing the insufficiency of essence. Fast food is made from the cattle which are fed the feed containing growth hormone and antibiotics in large quantities. Growth hormone causes the process of yang excessively in human body, while antibiotic suppresses the process of yin, leading to excessive damp-heat and hyperactive ministerial fire. Antiseptic included in instant food hampers the process of fermentation, or yin, and inhibits the digestion mechanism, obstructing damp-heat and bringing about hyperactive ministerial fire. Intake of excessive flesh and meat gives rise to incomplete combustion and hinders the creation of essence, causing hyperactive ministerial fire due to the lack of yin. Milk suits the calf that has a rapid growth cycle. Milk intake by humans leads to the rapid process of yang and eventually hyperactivity of ministerial fire. The imbalance between yin and yang, with essence insufficent and ministerial fire hyperactive, causes infertility in three aspects. First, the lack of essence itself makes conception difficult. Secondly, damp-sputum resulting from ministerial fire obstructs the circulation of qi and blood. It also hampers the normal supply of qi and blood to the uterus. Thirdly, the excessive process of yang may result in infertility. Generally speaking, pregnancy starts with implantation. If the excessive process of yang is in progress in body, static condition needed for implantation cannot be maintained, leading to infertility.

  • PDF

Prediction Principle and System Structure for the Detection of Incipient Electrical Fire (전기화재 예지원리 및 징후검출 시스템 구조)

  • 김창종
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.71-77
    • /
    • 1995
  • Electrical fire in residential, commercial, and industrial areas occupies 40 percent of overall fire accidents as of the year of 1994. The causes of most electrical fires were studied and, based on this investigation, the principle of the early detection or prediction of the electrical fires is developed. The basic principle is to early detect electrical arcs or sparks caused by faulty connections and insulation failures. the structure of the prediction system based on microcontroller technique is presented.

  • PDF

Electric Fire Prediction by Detection of Spark Signals (스파크 신호검출에 의한 전기화재 예측)

  • 김일권;송재용;길경석;권장우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.371-374
    • /
    • 2001
  • This paper describes a technique that can predict electric fires by detecting a spark signal generated from operation of electric facilities. An electric fire lead a loss of life as well as huge property, therefore it is very Important to predict an electric fire and eliminate the causes of it. Electrical spark which is ranked as majority causes of electric fires has a characterized frequency bandwidthdistinguishedfrompowerfrequenry. In the experiment, various spark signals are simulated in a condition such as short circuit, flashover and surface discharge. The results showed that the monitoring of spark signals can predict electric fires.

  • PDF

Properties of Temperature History of Lightweight Mortar for Fire Protection Covering Material in High Strength Concrete (고강도 콘크리트 내화피복용 경량 모르터의 온도이력 성상)

  • Lim, Seo-Hyung
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.45-50
    • /
    • 2012
  • The spalling causes the sever reduction of the cross sectional area with the exposure of the reinforcing steel, which originates a problem in the structural behaviour. By coating surface of high strength concrete with fireproof mortar, the high strength concrete is protected from the spalling in fire and the method to constrain the temperature increase of steel bar within the concrete. The purpose of this study is to investigate the temperature history properties of lightweight mortar using perlite and polypropylene fiber for fire protection covering material. For this purpose, selected test variables were the contents and length of polypropylene fiber. As a result of this study, it has been found that addition of polypropylene fiber to mortar modifies its pore structure and this causes the internal temperature to rise. And it has been found that a new lightweight mortar can be used in the fire protection covering material.

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF