• Title/Summary/Keyword: The amount of pollutant removal

Search Result 46, Processing Time 0.036 seconds

A Study on Low Concentrations of Organic Pollutants Removal using TiO2 (TiO2를 이용한 저농도 유기오염물질 제거에 관한 연구)

  • Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • Microbiological treatment, chlorination, and ozonation are usually used for water treatment. However, there is weakness that these methods can't decompose and eliminate recalcitrant organic pollutants perfectly. It is possible to eliminate recalcitrant organic pollutants when photocatalysis of $TiO_2$ is used. In this study, the removal efficiencies of organic pollutants by using photocatalyst of $TiO_2$ in the slightly polluted golf club water hazard and a river were investigated. The amount of $TiO_2$ was divided into three categories of 1 g/L, 2 g/L and 4 g/L in order to investigate the adequate amount of $TiO_2$ and the removal efficiency. UV light was used as a light source for the reaction of photocatalyst. As a conclusion in this study, the efficiency of turbidity removal was increased in proportion to the amount of $TiO_2$ until 4 hours. After then the turbidity was gradually decreased. Finally, the optimum concentration of $TiO_2$ was 4 g/L. The efficiency of COD removal was increased in proportion to the amount of $TiO_2$ regardless of time.

A Study on Efficient Operation of Cosmetic Wastewater Treatment Facility (화장품 폐수처리시설의 효율제고를 위한 처리비 영향인자에 관한 연구)

  • 장명옥;조춘구
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.1
    • /
    • pp.89-106
    • /
    • 1999
  • This research was undertaken to manage the waste treatment facility in cosmetic plants more effectively, The discharge and the treatment of pollutant in cosmetic plants were analyzed. And several factors which had an influential effect of the treatment cost, were found out. Effective management methods are proposed. Since average operating rate is estimated from 29% to 56%, the facility has an 44% to 71% surplus capacity. The pollutant removal rate influences highly on the treatment cost. The amount of MLSS is the factor that effects the removal rate. Chemical cost and the amount of the sludge are the influencing factors. To reduce the waste water treatment cost,-the saving of SV3O use and the management of MLSS amount are essential.

  • PDF

Acclimation of magnetic activated sludge with 1,4-dioxane and analysis of bacterial flora in the sludge

  • Toshiyuki Nikata;Hayato Ogihara;Yasuzo Sakai
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.7-12
    • /
    • 2023
  • Isolation of pollutant-degrading bacteria is important in bioaugmentation, one of the methods for biological degradation of environmental contaminants. We focused on the magnetic activated sludge (MAS) process as a culture method that efficiently concentrates degrading bacteria, and cultured activated sludge with 1,4-dioxane as a model pollutant. After 860 days of operation, MLVSS, which indicates the amount of sludge, increased from 390 mg/L to 10,000 mg/L, and the removal rate of organic matter including 1,4-dioxane, tetrahydrofuran, and glucose in the artificial wastewater reached up to 97%. Based on these results, the MAS process was successfully used to acclimate activated sludge with 1,4-dioxane. Bacterial flora analysis in the MAS showed that bacteria of the genus Pseudonocardia, already reported as 1,4-dioxane degrading bacteria, play an important role in the degradation of this pollutant. The MAS process is a suitable culture method for acclimation of environmental pollutants, and the findings indicate that it can be used as an enrichment unit for pollutant-degrading bacteria.

Pollutant Runoff Reduction Efficiency of Surface Cover, Vegetative Filter Strip and Vegetated Ridge for Korean Upland Fields: A Review

  • Park, Se-In;Park, Hyun-Jin;Yang, Hye In;Kim, Han-Yong;Yoon, Kwang-Sik;Choi, Woo-Jung
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.3
    • /
    • pp.151-159
    • /
    • 2018
  • BACKGROUND: In this review paper, the effects of surface cover (SCV), vegetative filter strip (VFS), and vegetated ridge (VRD) on the pollutant runoff from steep-sloping uplands were analyzed to compare the pollutant reduction efficiency in runoff ($PRE_{runoff}$) of the practices and to investigate how slope and rainfall parameters affect the $PRE_{runoff}$. METHODS AND RESULTS: The $PRE_{runoff}$ of SCV, VFS, and VRD for pollutants including suspended solids and biological oxygen demand was compared by analysis of variance. The effect of slope and rainfall parameters on the $PRE_{runoff}$ was explored by either mean comparison or regression analysis. It was found that the $PRE_{runoff}$ differs with the practices due to different pollutant reduction mechanisms of the practices. Though the $PRE_{runoff}$ was likely to be affected by site condition such as slope and rainfall (amount and intensity), more comprehensive understanding was not possible due to the limited data set. CONCLUSION: The $PRE_{runoff}$ of SCV, VFS, and VRD differed due to the distinctive mechanisms of pollutant removal of the practices. It is necessary to accumulate experimental data across a variety of gradient of slope and rainfall for comprehensive understanding of the effects of the practices on pollutant runoff from steep-sloping uplands.

Feasibility Study of Constructed Wetland System for Sewage Treatment in Rural Area

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.5
    • /
    • pp.426-432
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the feasibility of constructed wetland system for sewage treatment in rural areas. A pilot system was installed in Konkuk University and the effluent of septic tank for school building was used as an influent to the wetland treatment basin. The system was composed of sand and reed, and operated continuously including winter time. Average removal rate of about 70% was observed for BOD, COD, and SS, about 50% for T-P, and about 25% for T-N. The reason for poor T-N removal might be due to high loading rate and short retention time. The system demonstrated satisfactory effluent concentration and stable performance in growing season. And it also worked adequately in wintertime even below $10^{\circ}C$ without freezing, and removal was still significant. The amount removed in BOD, COD, and SS was almost the same as in the growing season, and the amount removed in nutrients was about half of the one in growing season. Overall performance of the experimental system was compared with existing data base (NADB, 1994), and it was within the range of general system performance. As study period increased, removal rates for BOD, COD, SS, and T-P were consistently maintained and even enhanced, but removal rate for T-N decreased slightly. Wetland system was thought to be a feasible alternative for sewage treatment in rural area considering its low cost and low maintenance requirement. However, the effluent of the experimental wetland system often exceeded current effluent water quality standards, therefore, further treatment could be required if the effluent should be discharged to public waters. Wetland system of interest locates in rural area and is a part of rural ecosystem, therefore, ultimate disposal of reclaimed sewage for agricultural purpose or subsequent land treatment might be available and further research in this matter is recommended.

  • PDF

Preparation and Characterization of Electrospun TiO2-Activated Carbon Complex Fiber as Photocatalyst

  • Jung, Min-Jung;Jeong, Eui-Gyung;Jang, Jeen-Seok;Lee, Young-Seak
    • Carbon letters
    • /
    • v.11 no.1
    • /
    • pp.28-33
    • /
    • 2010
  • In this study, $TiO_2$-Activated carbon (AC) complex fibers were prepared by electrospinning for the synergetic effect of adsorption and degradation of organic pollutant. The average diameter of these fibers increased with increasing the amount of AC added, except for 1AC-TOF (AC$/TiO_2$ =1/40 mass ratio). After calcinations at $500^{\circ}C$, long as-spun fibers were broken and their average diameter was slightly decreased. The resultant fibers after calcination had rough surface and sphere shapes like a peanut. From XRD results, it was confirmed that as-spun fibers were changed to anatase $Ti_O2$ fiber after calcinations at $500^{\circ}C$. The prepared $TiO_2$-AC complex fibers could remove procian blue dyes by solar light irradiation with high removal property of 94~99%. The PB dye was rapidly removed by adsorption during the initial 5 minutes. But after 5 minutes, dye removal was occurred by photodegradation. In this study, the most efficient AC/$TiO_2$ ratio of $TiO_2$-AC complex fibers was 5/40, showing the synergetic effect of adsorption and photodegradation. It is expected that the $TiO_2$-AC complex fibers can be used to remove of organic pollutants in water system.

Reduction of Pollutant Concentrations in Urban Stormwater Runoff by Settling (침강에 의한 도시 강우 유출수 오염물질 저감 특성 분석)

  • Seo, Dongil;Kim, Jaeyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.210-218
    • /
    • 2016
  • The pollutant removal efficiencies of stormwater runoff by settling were analyzed using field samples collected in 4 different raining events in a test bed installed in the Gwanpyung-Cheon stream in Daejeon. A 1.8 m high with 30 cm diameter cylindrical settling device was used for the settling test by measuring concentration of TSS, TP and TN for time and height. The pollutants removal rate was relatively high in the first 4 hours while 24 hours seem to be necessary to reach steady state in pollutant concentrations. However, there were no considerable differences in concentrations for height at a given time. This indicates most of particulate pollutant in the test seems to show independent settling with no interference to each other. Much part of particle sizes were distributed in the range of $10{\sim}100{\mu}m$. Average particulate fractions of TP and TN were estimated as 52.4% and 23.5%, respectively. This results explain why TN is difficult to remove by simple settling. This study indicates that a simple settling can provide effective method to remove significant amount of TSS and TP effectively and this can be used to protect urban river water quality.

Removal of S $O_{2}$ and NO by Dry Sorbent(II) - Efficiency of Cu-Ce and Cu-7Al - (건식법에 의한 이산화황과 산화질소의 제거(II) - Cu-Ce 및 Cu-7Al의 효율 -)

  • 신창섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.288-294
    • /
    • 1993
  • Flue gas control systems for small-scale combustors must be designed to provide highly effective removal of three criteria pollutants (S $O_{2}$, N $O_{x}$ and particulate matter), and must be safe, reliable and small. These requirements make dry, regenerative clean-up process particularly attractive and this paper describes a new concept for integrated pollutant control : a filter comprised of layered, gas permeable membranes that act as an S $O_{2}$ sorbant, a N $O_{x}$ reduction catalyst and a particulate filter. A mixed metal oxide sorbent, Cu-Ce was used as a sorbent/catalyst and the activity was compared with Cu-7Al. The S $O_{2}$ removal eficiency of Cu-Ce was increased with temperature increase up to 500$^{\circ}$C and the catalytic activity for NO was higher than that of Cu-7Al. By the sulfation of Cu-Ce, the reduction activity was increased at the temperature higher than 350$^{\circ}$C. The regeneration of Cu-Ce was very fast and some amount of elemental sulfar was found.

  • PDF

Production Conditions of the Photo-catalyst for Removing Indoor Pollutants (실내오염물질 제거용 광촉매의 제조조건에 따른 반응활성 연구)

  • Nam, Ki Bok;Park, In Chul;Hong, Sung Chang
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • This study was performed to study the photocatalyst for controlling the pollutant such as CO, C2H5OH and H2S by the UV light. This was shown in a catalyst having the same volume and the same surface area, that the structure in which the UV light to reach the interior structure exhibits more excellent activity. However, the activity of this activity of this photocatalyst removal of CO was very low. This problem can be solved by performing a reduction process by the addition of the precious metal series of Pt. Particularly, the amount of chemical species Pt0 incerased in the surface of Pt/TiO2 photocatalyst through the reduction process, which make the reaction activity of photocatalyst excellent to the removal of the CO.

Study on the Removal of Fluorescent Whitening Agent for Paper-mill Wastewater Reuse using the Submerged Membrane Bioreactor(SMBR) with Ozone Oxidation Process (제지폐수 재이용을 위한 침지형 생물막 여과와 오존산화공정(SMBR-Ozone Oxidation Process)에 의한 형광증백제 제거에 관한 연구)

  • Choi, Jang-Seung;Shin, Dong-Hun;Ryu, Seung-Han;Lee, Jae-Hun;Ryu, Jae-Young;Shin, Won-Sik;Lee, Seul-Ki;Park, Min-Soo;Lee, Sang Oh
    • Textile Coloration and Finishing
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2018
  • In this study, effluent water was produced through Submerged Membrane Bio-Reactor(SMBR) process, which is a simple system and decomposes organic matter contained in wastewater with biological treatment process and performs solid-liquid separation, Especially, ozone oxidation treatment process is applied to effluent water containing fluorescent whitening agent, which is a trace pollutant which is not removed by biological treatment, and influences the quality of reused water. The concentration of $COD_{Cr}$ in the SMBR was $449.3mg/{\ell}-COD_{Cr}$, and the concentration of permeate water was $100.3mg/{\ell}-COD_{Cr}$. The removal efficiency was about 70.1%. The amount of ozone required for the removal of the fluorescent whitening agent in the permeated water in SMBR was $6.67g-O_3/min$, and the amount of ozone required to remove $COD_{Mn}$ relative to the permeate water was calculated to remove $0.997mg-COD_{Mn}$ for 1mg of $O_3$.