• Title/Summary/Keyword: The Plot of Image

Search Result 90, Processing Time 0.036 seconds

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Development of Evaluation Method of Regional Contractility of Left Ventricle Using Gated Myocardial SPECT and Assessment of Reproducibility (게이트 심근 SPECT를 이용한 좌심실의 국소탄성률 평가방법 개발 및 재현성 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.355-363
    • /
    • 2003
  • Purpose: Regional contractility can be calculated using the regional volume change of left ventricle measured by gated myocardial SPECT image and curve of central artery pressure obtained from radial artery pressure data. In this study, a program to obtain the regional contractility was developed, and reproducibility of regional contractility measurement was assessed. Materials and Methods: Seven patients(male:female=5:2, $58{\pm}11.9$ years) with coronary artery diseases underwent gated Tc-99m MIBI myocardial SPECT twice without delay between two scans. Regional volume change of left ventricle was estimated using CSA (Cardiac SPECT Analyzer) software developed in this study. Regional contractility was iteratively estimated from the time-elastance curve obtained using the time-pressure curve and regional time-volume curve. Reproducibility of regional contractility measurement assessed by comparing the contractility values measured twice from the same SPECT data and by comparing those measured from the pair of SPECT data obtained from a same patient. Results: Measured regional contractility was $3.36{\pm}3.38{mm}Hg/mL$ using 15-segment model, $3.16{\pm}2.25{mm}Hg/mL$ using 7-segment model, and $3.11{\pm}2.57{mm}Hg/mL$ using 5-segment model. The harmonic average of regional contractility value was almost identical to the global contractility. Correlation coefficient of regional contractility values measured twice from the same data was greater than 0.97 for all models, and two standard deviations of contractility difference on Bland Altman plot were 1.5%, 1.0%, and 0.9% for 15-, 7-, and 5-segment models, respectively. Correlation coefficient of regional contractility values measured from the pair of SPECT data obtained from a same patient was greater than 0.95 for all models, and two standard deviations on Bland Altman plot were 2.2%, 1.0%, and 1.2%. Conclusion: Regional contractility of left ventricle measured using developed software in this study was reproducible. Regional contractility of left ventricle will be a new useful index for myocardial function after analysis of the clinical data.

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Physio-mechanical and X-ray CT characterization of bentonite as sealing material in geological radioactive waste disposal

  • Melvin B. Diaz;Sang Seob Kim;Gyung Won Lee;Kwang Yeom Kim;Changsoo Lee;Jin-Seop Kim;Minseop Kim
    • Geomechanics and Engineering
    • /
    • v.34 no.4
    • /
    • pp.449-459
    • /
    • 2023
  • The design and development of underground nuclear waste repositories should cover the performance evaluation of the different components such as the construction materials because the long term stability will depend on their response to the surrounding conditions. In South Korea, Gyeonju bentonite has been proposed as a candidate to be used as buffer and backfilling material, especially in the form of blocks to speed up the construction process. In this study, various cylindrical samples were prepared with different dry density and water content, and their physical and mechanical properties were analyzed and correlated with X-ray CT observations. The main objective was to characterize the samples and establish correlations for non-destructive estimation of physical and mechanical properties through the utilization of X-ray CT images. The results showed that the Uniaxial Compression Strength and the P-wave velocity have an increasing relationship with the dry density. Also, a higher water content increased the values of the measure parameters, especially for the P-wave velocity. The X-ray CT analysis indicated a clear relation between the mean CT value and the dry density, Uniaxial Compression Strength, and P-wave velocity. The effect of the higher water content was also captured by the mean CT value. Also, the relationship between the mean CT value and the dry density was used to plot CT dry densities using CT images only. Moreover, the histograms also provided information about the samples heterogeneity through the histograms' full width at half maximum values. Finally, the particle size and heterogeneity were also analyzed using the Madogram function. This function identified small particles in uniform samples and large particles in some samples as a result of poor mixing during preparation. Also, the μmax value correlated with the heterogeneity, and higher values represented samples with larger ranges of CT values or particle densities. These image-based tools have been shown to be useful on the non-destructive characterization of bentonite samples, and the establishment of correlations to obtain physical and mechanical parameters solely from CT images.

Functionalized Graphene/Polyimide Nanocomposites under Different Thermal Imidization Temperatures (열 이미드화 온도에 따른 작용기화 그래핀/폴리이미드 나노복합재료)

  • Ju, Jieun;Chang, Jin-Hae
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.88-98
    • /
    • 2015
  • 4-Amino-N-hexadecylbenzamide-graphene sheets (AHB-GSs), used in the preparation of the polyimide (PI) nanocomposite films, were synthesized by mixing a dispersion of graphite oxide with a solution of the ammonium salt of AHB. The atomic force microscope image of functionalized-GS on mica and a profile plot revealed the average thickness of AHB-GS to be ~3.21 nm. PI films were synthesized by reacting 4,4'-biphthalic anhydride and bis(4-aminophenyl) sulfide. PI nanocomposite films containing various contents of AHB-GS over the range of 0-10 wt% were synthesized using the solution intercalation method. The PI nanocomposite films under different thermal imidization temperatures, 250 and $350^{\circ}C$, were examined. The graphenes, for the most part, were well dispersed in the polymer matrix despite some agglomeration. However, micrometer-scale particles were not detected. The average thickness of the particles was <10 nm, as revealed from the transmission electron microscope images. Only a small amount of AHB-GS was required to improve the gas barrier, and electrical conductivity. In contrast, the glass transition and initial decomposition temperatures of the PI hybrid films continued to decrease with increasing content of AHB-GS up to 10 wt%. In general, the properties of the PI hybrid films heat treated at $350^{\circ}C$ were better than those of films heat treated at $250^{\circ}C$.

Functional Analysis of Classical Music in Film: Focused on (영화 속 클래식 음악의 기능분석:영화 <체실비치에서>를 중심으로)

  • Kang, Unsu;Ahn, Soo Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.3
    • /
    • pp.152-164
    • /
    • 2022
  • This thesis explores the relationship between Dominic Cooke's film (2017) and classical music. To analyze the relationship, researchers applied precedent research to the study. The relationship between the final scene of the movie King's Speech (2010) and the volume and instrumental changes of the Beethoven Symphony is analyzed by David Bashwiner, and Soohwan Ahn analyzed semantic association between the hotel conversation scene in a and Debussy's Arabesque. In addition, the study of application of Schumann's Träumerei to films was used as a methodology to find out how extra-musical information build meaningful sonority. Mozart's K.593, Haydn's Op.77 No.1, and Schubert's D.810 were used in the movie . This study analyzed the functions of Mozart, Haydn, and Schubert's music in . In order to express the relationship between the characters and their inner intentions, this film utilized the relationship between instruments, musical information and non-musical information of the pieces. Through this study, it is analyzed that the information of classical music functions and the core information of the plot of the movie combine together to improve the understanding of narrative.

Development of big data based Skin Care Information System SCIS for skin condition diagnosis and management

  • Kim, Hyung-Hoon;Cho, Jeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.137-147
    • /
    • 2022
  • Diagnosis and management of skin condition is a very basic and important function in performing its role for workers in the beauty industry and cosmetics industry. For accurate skin condition diagnosis and management, it is necessary to understand the skin condition and needs of customers. In this paper, we developed SCIS, a big data-based skin care information system that supports skin condition diagnosis and management using social media big data for skin condition diagnosis and management. By using the developed system, it is possible to analyze and extract core information for skin condition diagnosis and management based on text information. The skin care information system SCIS developed in this paper consists of big data collection stage, text preprocessing stage, image preprocessing stage, and text word analysis stage. SCIS collected big data necessary for skin diagnosis and management, and extracted key words and topics from text information through simple frequency analysis, relative frequency analysis, co-occurrence analysis, and correlation analysis of key words. In addition, by analyzing the extracted key words and information and performing various visualization processes such as scatter plot, NetworkX, t-SNE, and clustering, it can be used efficiently in diagnosing and managing skin conditions.

Girls' Technoscience Story: Reflexivity on Technoscience in Girls' Comics (소녀들의 감성으로 본 과학: 소녀만화에 나타난 과학에 대한 성찰성)

  • Yun, Seon-Hui
    • Journal of Science and Technology Studies
    • /
    • v.14 no.2
    • /
    • pp.281-318
    • /
    • 2014
  • This paper aims to examine women's understanding of technoscience by analyzing girls' comics(少女漫畵, Sonyeo Manhwa). The idea that women were not interested in science was a socially accepted. But this paper reveals that women are interested in science in a different way by analyzing Korean SF girls' comics. By examining an image of science in SF girls' comics in comparison to SF boys' comics(少年漫畵, Sonyeon Manhwa), this paper shows that women look technoscience through 'reflexivity' focused on 'human' and that this special character is derived from the feature of women's culture. SF girls comics have two features. First, girls comics reflect on power made by technoscience rather than describe it elaborately. And the reflexivity is expressed through a mental state, an emotion, and relations between human beings focused on a human nature, an ego, and an identity. It is different from boys comics that give weight to the mechanics and that show simple plot such as utopia or distopia, or a battle of good versus evil. Second, girls comics express technoscience as daily practices. In girls comics, some technosciences are linked to our daily lives and cartoonists and readers consider an 'essence of knowledge' together. It is different from men's view that regards knowledge as power or means.

  • PDF

Identification of Genes Connected with the Sensitivity to 5-FU and Cisplatin in Squamous Cell Carcinoma Cell Lines (편평세포암 세포주에서 5-FU와 Cisplatin에의 감수성과 관련된 유전자의 동정)

  • Choi, Na-Young;Kim, Ok-Joon;Lee, Geum-Sug;Kim, Byung-Gook;Kim, Jae-Hyeong;Jang, Youn-Young;Lim, Won-Bong;Chong, Min-A;Choi, Hong-Ran
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.287-300
    • /
    • 2005
  • Squamous cell carcinoma (SCC) in head and neck show a variability in the response to chemotherapy, even when it present with similar histological tumor type, grade, and clinical stage. The purpose of present study it to identify predictive bio-marker for the sensitivity or resistance to conventional chemotherapeutic agents, 5-fluorouracil (5-FU) and Cisplatin Oral cancer cell lines were used in present study. MTT assay was performed to evaluate the sensitivity and/or resistance to 5-FU and Cisplatin. And RT-PCR was carried out for evaluation of the mRNA expressions of various genes associated with mutation, inflammation (COX pathway), cell cycle, senescence and extracellular matrix (ECM). The molecules which are correlated with the sensitivity to 5-FU are XPA, XPC, OGG, APEX, COX-2, PPAR, Cyclin E, Cyclin B1, CDC2, hTERT, hTR, TIMP-3, TIMP-4 and HSP47. And the molecules are correlated with the sensitivity to Cisplatin are COX-1, iNOS, eNOS, PCNA, collagen 1 and MMP-9. Taken together, when choosing the appropriate chemotherpeutic agents for patients, considering the molecules which are correlated or reversely correlated is helpful to choose the resonable agents for cancer patients.

Overview of Research Trends in Estimation of Forest Carbon Stocks Based on Remote Sensing and GIS (원격탐사와 GIS 기반의 산림탄소저장량 추정에 관한 주요국 연구동향 개관)

  • Kim, Kyoung-Min;Lee, Jung-Bin;Kim, Eun-Sook;Park, Hyun-Ju;Roh, Young-Hee;Lee, Seung-Ho;Park, Key-Ho;Shin, Hyu-Seok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.236-256
    • /
    • 2011
  • Forest carbon stocks change due to land use change is an important data required by UNFCCC(United Nations framework convention on climate change). Spatially explicit estimation of forest carbon stocks based on IPCC GPG(intergovernmental panel on climate change good practice guidance) tier 3 gives high reliability. But a current estimation which was aggregated from NFI data doesn't have detail forest carbon stocks by polygon or cell. In order to improve an estimation remote sensing and GIS have been used especially in Europe and North America. We divided research trends in main countries into 4 categories such as remote sensing, GIS, geostatistics and environmental modeling considering spatial heterogeneity. The easiest way to apply is combination NFI data with forest type map based on GIS. Considering especially complicated forest structure of Korea, geostatistics is useful to estimate local variation of forest carbon. In addition, fine scale image is good for verification of forest carbon stocks and determination of CDM site. Related domestic researches are still on initial status and forest carbon stocks are mainly estimated using k-nearest neighbor(k-NN). In order to select suitable method for forest in Korea, an applicability of diverse spatial data and algorithm must be considered. Also the comparison between methods is required.