Development of Evaluation Method of Regional Contractility of Left Ventricle Using Gated Myocardial SPECT and Assessment of Reproducibility
![]() |
Lee, Byeong-Il
(Department of Information & Computer Engineering, Inje University)
Lee, Dong-Soo (Department of Nuclear Medicine, Seoul National University College of Medicine) Lee, Jae-Sung (Department of Nuclear Medicine, Seoul National University College of Medicine) Kang, Won-Jun (Department of Nuclear Medicine, Seoul National University College of Medicine) Chung, June-Key (Department of Nuclear Medicine, Seoul National University College of Medicine) Lee, Myung-Chul (Department of Nuclear Medicine, Seoul National University College of Medicine) Choi, Heung-Kook (Department of Information & Computer Engineering, Inje University) |
1 | Germano G, Kavanagh PB, Waechter P, Areeda J, Kriekinge SV, Sharir T, et al. A new algorithm for the quantitation of myocardial perfusion SPECT.I: Technical principles and reproducibility. J Nucl Med 2000;41:712-19 PUBMED |
2 | Lee BI, Lee JS, Lee DS. Regional contractility measurement of the left ventricle using gated myocardial SPECT. Proceedings of IEEE MIC 2002; M10-229 |
3 | Lee DS, Kim KM, Kim SK, Cheon GJ, Kim YK, Chung J-K, et al. Development of a method for measuring myocardial contractility with gated myocardial SPECT and arterial tonometry. J Nucl Cardiol. 1999;6:657-63 DOI ScienceOn |
4 | yoshizawa M, Abe KI, Tokeda H, Tambe T, Nitta SI. Classical but effective techniques for estimating cardiovascular dynamics: achieving accurate results using linear models. IEEE Eng in Med Biol Mag,1997; 16:106-12 |
5 | Lee BI, Lee DS, Lee JS, Choi HK. Development of gated myocardial SPECT analysis software and evaluation of left ventricular contraction function. Korean J Nucl Med, 2003;(2)37:1-10 |
6 | Paeng JC, Lee DS, Cheon GJ, Kim YK, Chung J-K, Lee MC. Reproducibility of an automatic quantitation of regional myocardial wall motion and systolic thickening on gated Tc-99m MIBI myocardial SPECT. J Nucl Med, 2001;42:779-84 |
7 | Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su H-T, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47 PUBMED |
8 | Faber TL, Cooke CD, Folks RR, Vansant JP, Nichols KJ, DePuey EG, et al. Left ventricular function and perfusion from gated SPECT perfusion images: An integrated method. J Nucl Med 1999;40:650-59 PUBMED |
9 | Kim KM, Lee DS, Kim YK, Cheon GJ, Kim SK, Chung JK, et al. Reproducibility of non-invasive measurement for left ventricular contractility using gated myocardial SPECT. Korean J Nucl Med, 2001;35:152-60 |
10 | Sharir T, Marmor A, Ting CT, Chen JW, Liu CP, Chang MS, et al. Validation of a method for noninvasive measurement of central arterial pressure. Hypertension 1993;21:74-82 DOI PUBMED ScienceOn |
11 | Senzaki H, Chen C-H, Kass DA. Single-beat estimation of end-systolic pressure-volume relation in humans: a new method with the potential for noninvasive application. Circulation 1996;94: 2497-2506 DOI PUBMED ScienceOn |
12 | Suga H. Paul Dudley. White International Lecture: Cardiac performance as viewed through the pressure-volume window. Jpn Heart J, 1994;35: 263-80 |
![]() |