• Title/Summary/Keyword: The Next generation

Search Result 5,230, Processing Time 0.042 seconds

A Development of MMI using Open Interface (Open Interface를 적용한 MMI 개발)

  • Oh, S.M.;Min, B.U.;Lee, S.J.;Choi, M.S.;Yoon, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.253-255
    • /
    • 2002
  • The paper presets the improvements of MMI at the PROSET2000 correction program which is totally computerized system of the power system protection. The Base Form that is an open interface is developed to be able to compose the screen by reading the input screen from the database. It also is developed to be suitable for the environment of the Graphical User Interface instead of the DOS window when the users do the pannel settings. Program development in this paper is designed by Unified Modeling Language(UML) techniques.

  • PDF

Power Prediction of P-Type Si Bifacial PV Module Using View Factor for the Application to Microgrid Network (View Factor를 고려한 마이크로그리드 적용용 고효율 P-Type Si 양면형 태양광 모듈의 출력량 예측)

  • Choi, Jin Ho;Kim, David Kwangsoon;Cha, Hae Lim;Kim, Gyu Gwang;Bhang, Byeong Gwan;Park, So Young;Ahn, Hyung Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.3
    • /
    • pp.182-187
    • /
    • 2018
  • In this study, 20.8% of a p-type Si bifacial solar cell was used to develop a photovoltaic (PV) module to obtain the maximum power under a limited installation area. The transparent back sheet material was replaced during fabrication with a white one, which is opaque in commercial products. This is very beneficial for the generation of more electricity, owing to the additional power generation via absorption of light from the rear side. A new model is suggested herein to predict the power of the bifacial PV module by considering the backside reflections from the roof and/or environment. This model considers not only the frontside reflection, but also the nonuniformity of the backside light sources. Theoretical predictions were compared to experimental data to prove the validity of this model, the error range for which ranged from 0.32% to 8.49%. Especially, under $700W/m^2$, the error rate was as low as 2.25%. This work could provide theoretical and experimental bases for application to a distributed and microgrid network.

Design of Next Generation Mobile Convergence Service Business Model (차세대 이동통신 컨버젼스 서비스를 위한 비즈니스 모델 개발)

  • Ryu, Seung-Wan;Kim, Jin-Bae;Sin, Dong-Cheon;O, Don-Seong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2007.11a
    • /
    • pp.358-373
    • /
    • 2007
  • In this paper, we proposed the next generation mobile convergence service business model creation methodology. In order to establish such a business model creation methodology framework, we first introduce the service model based on our previous research results on next generation mobile convergence services. The service model contains several components such as infrastructures, operations, and provision of services that are indispensible for providing the next generation mobile services. Finally, by adding service and value flows to the developed service model, we propose the next generation mobile services business model creation methodology. To achieve this objective, we first derive necessary components of business model including actors, their relationships, and roles. In addition, we propose service composition methodology for creating new mobile services and its corresponding business models.

  • PDF

Data Compression using Waveform Comparison (파형 비교를 이용한 데이터 압축 기법)

  • Sung, S.M.;Lim, S.I.;Lee, S.J.;Bae, Y.J.;Jin, Y.W.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.151-153
    • /
    • 2003
  • This paper was studied on using data of the protective relay by Power Quality Monitor. The protective relay will have problem to save data for PQM(Power Qualify Monitoring) analysis because the protective relay memory is limited. So this paper was proposed new data compression of the data was get from the protective relay. The scheme is compared each cycle after DFT(Discrete Fourier Transform). And scheme is verified through simulation of protective relay data was from real distribution system.

  • PDF

Adaptive Over Current Relay for power systems having Decentralized Generator (분산전원용 적응형 과전류 계전기)

  • Kim, Hyung-Kyu;Song, Hwang-Bin;Ahn, Jong-Pil;Jeong, Cheal-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.195-196
    • /
    • 2008
  • Output of wind generators are changed by windy level. The change of the output also affects the amplitude of fault current. And this fault current causes OCR's mal-operation. To solve the problem, this paper adopts that Over Current Relay adapted for Decentralized generator algorithm.

  • PDF

A Study on the Development of Protection Relay applied a Generator Protection Basic Algorithm (발전기 보호 기본 알고리즘을 적용한 보호계전 연구)

  • Cho, Seong-Jin;Choi, Myeong-Song;Lee, Seung-Jae;Kang, Sang-Hee;Hyun, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.326-328
    • /
    • 2003
  • In this paper, in order to generator protection from a electrical fault was occurred while a generator is operated, principles of existing generator protection algorithm is examined and analyzed. and a new generator protection algorithm was developed. also, during a generator operation, Algorithm, an analysis for the basic principle of protective relay to general faults, was developed. This paper, generator was simple analyzed on the assumption that three-phase winding and observe the IEEE std.

  • PDF

A fault location algorithm for underground cable by Distributed Parameter Circuit Analysis (분포정수회로 해석을 통한 지중케이블 고장거리 알고리즘 연구)

  • Yang, Xia;Bae, Y.J.;Choi, M.S.;Lee, S.J.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.171-173
    • /
    • 2003
  • This paper presents a new fault location algorithm for 3 phase underground cable based on distributed parameter circuit analysis, by which we establish the basic equations for each of core and sheath currents and voltages considering cross-bonding sheaths. The proposed algorithm need simulate by EMTP, and then the EMTP data need be compared with the calculation result in Matlab.

  • PDF

The Safety Analysis under failure of the 1st and 2ne Suspension Elements of the Next Generation High-speed Train model (차세대 고속철도 차량 모델의 1.2차 현가요소의 고장 발생 시 안전성 해석)

  • Kim, Ji-Young;Park, Tae-Won;Yoon, Ji-Won;Cho, Jae-Ik
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.984-988
    • /
    • 2010
  • In Korea, the next generation high-speed train, whose target is maximum speed of 400km/h and operating speed of 370km/h, has been developed since 2007. In this paper, the safety of the next generation high-speed train is compared UIC 518OR under the malfunctioning situation of the suspension system. The bogie of the next generation high-speed train has two suspensions. Two different vehicle models of the next generation high-speed train are created by using VAMPIRE and ADAMS/Rail, which are specialized to design railway vehicle. And Those models are showed same dynamic properties. First of all, the sensitivity analysis of ModelCenter is performed using model of VAMPIRE. One suspension element which has significant effects on the safety are selected by result of the sensitivity analysis. And then, the dynamic analysis when the suspension element is broken is performed using ADAMS/Rail. The 30km track between Pungsegyo and Biryong tunnel in Gyeongbu High-speed Line was used at the dynamic analysis. The estimated value is found by using the normal method of UIC 518OR. The estimated values on the normal/fault state and the limit values of UIC 518OR are compared. Finally, the safety of the next generation high-speed train is verified.

  • PDF

Implementation of an Over-Current Relaying Algorithm with TMS320C32 (TMS320C32를 이용한 한시 과전류 계전기의 구현)

  • Yoo, Sung-Rok;Yoon, Byung-Wook;Park, Byung-Woo;Choi, Chang-Yung;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2193_2194
    • /
    • 2009
  • A digital over current relay(OCR) is realized by using TMS320C32 microprocessor. Fourier Transform is used to obtain the phasor of a current signal and a 2nd low pass filter is adopted to prevent aliasing error. H/W test shows almost same results with those of the S/W test. It could be possible that confirm simularity between H/W and S/W test in this paper.

  • PDF

A study on An Optimal Protection System for Power Distribution Networks by Applying Multi-Agent System (Multy-agent system을 애용한 배전계통 최적 보호시스템 연구)

  • Jung, K.H.;Min, B.W.;Lee, S.J.;Choi, M.S.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.299-301
    • /
    • 2003
  • In this paper, a protection system using Multi-Agent concept for power distribution network is proposed. Multi agent system consist of Feeder agent, OCR(Over Current Relay) agent, Recloser agent and Switch agent. An agent calculates and corrects its parameter by itself through communication with neighboring agents and its own intelligence algorithm. Simulations in a simple distribution network show the effectiveness of the suggested protection system. Multi-Agent System, protection of distribution network, Communication.

  • PDF