• 제목/요약/키워드: The Electrical Fires

검색결과 184건 처리시간 0.026초

화원에 따른 광전식 연기감지기 반응시간 분석 (Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires)

  • 지승욱
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

전기화재 예방과 신속 감지를 위한 추론기반 지능형 수배전반 시스템 구현 연구 (Implementation of a Inference based Intelligent Distribution Panel System for Prevention and fast Detection of fire caused by Electricity)

  • 박찬엄;김경동;이승철;양원영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.82-85
    • /
    • 2006
  • With the fast growing number of skyscrapers and large ultrahigh apartment complexes, the concerns on fire caused by electricity also grow. Among about 30,000 fires recorded annually, roughly one third of them are hewn to be caused by electricity. If one of such high and densely populated buildings or apartments catches a fire, the consequence can potentially be quite catastrophic. However, with the rapid development of the techniques in the fields of communications and computers, electric power distribution systems for such buildings and apartments have been largely digitalized in recent years. More detailed informations on the operating status are now available, which enables more sophisticated monitoring and early detection of potential fire caused by electricity. In this paper, we present an inference technique that can be used as one of the basic techniques in building intelligent distribution panel systems that can effectively monitor, prevent and detect the occurrence of fire caused by electricity. The technique can accommodate production rules in linguistic expressions on high abstraction levels. Fire finding strategies can be easily modified to provide more effective countermeasures. Simulation results show that inference capabilities and thus the capability of fire monitoring in power distribution panel systems can be significantly enhanced with our approach.

  • PDF

플러그 내부에서 발생된 소선 단선에 의한 발열특성 (The Thermal Characteristics of Partially Disconnected Wire Happened in Plug)

  • 지승욱;김시국;이춘하
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.104-110
    • /
    • 2011
  • There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current's condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire.

전동기 소손에 대한 화재 원인 분석에 관한 연구 (A Study on the Fire Cause Analysis of Motor Damage)

  • 이춘하;옥경재;권병덕
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.59-64
    • /
    • 2007
  • 본 논문은 전동기에 발생하는 화재에 대한 연구로서, 일반가전제품에 사용되고 있는 단상유도전동기에 과부하 및 외부화염을 가하여 그 변형 및 파손상태를 비교 분석하였다. 실험은 전동기의 구속을 통한 과부하 시험과 외부에서 화염을 가하는 실험으로 진행하였으며, 외부화염 시험의 경우 전압을 인가한 경우와 인가하지 않은 경우로 구분하였다. 실험결과 구속을 통한 과부하 시험의 경우 권선부분에서 층간 단락흔을 관찰할 수 있었고, 권선부분의 조직에서는 과부하에 의해 변형된 전선의 특징인 나무줄기 형상의 수지상 조직이 나타났다. 전압을 인가한 상태에서 외부화염을 가한 경우 고정자 권선부분의 코일이 원형을 유지하고 있는 것을 확인할 수 있었고, 권선주변의 색이 붉게 변색된 것을 볼 수 있었다. 전압을 인가하지 않고 외부화염을 가한 경우 고정자 권선부분의 코일이 원형에서 많이 변형된 것을 관찰할 수 있었고, 권선 주변의 색은 전압을 인가한 경우와 마찬가지로 붉게 변색된 것을 확인할 수 있었다.

Ag-Cu 합금을 이용한 매우 빠른 동작 특성의 퓨즈 엘리멘트 설계 (Design of very fast acting fuse element using the Ag-Cu alloy)

  • 김은민;이승환;조대권;김신효
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1070-1074
    • /
    • 2014
  • With the development of the electronics industry and widespread supply of many different electrical appliances, the factors of the electrical fires are also diversified. For this reason, the fuse, safety-critical component, needs accurate and stable operating characteristics for preventing various fire factor, and also needs various operating characteristics. Especially when the all electrical resistance are dropped by internal short of circuit, high current inrushes and makes the fire. In order to prevent this, very fast acting fuses should be applied. However, existing very fast acting characteristics fuse has less wire dimension of element Ag100% metal than that of fast acting fuse, and it is made of plating with low melting point metals, so it satisfy very fast acting but it can't satisfy durability and safety. For this reason, in this study, through the analyzing fusing characteristics of Ag-Cu alloy composition, the new alloy composition, which implement to very fast acting fuse without decrease of fuse elements dimension, is suggested. And this study classify the operating characteristics changes, a resistance change, and the rated current of the fuse in the overall composition change of Ag-Cu alloying. and it can be utilized for designing fuse.

전기분전반용 블록형 부스 바의 구조 설계 연구 (The Structural Design of the Bus-bar block type of electrical switch boards)

  • 권영민;황찬규;김근호;한희
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.378-385
    • /
    • 2016
  • 전기 분 배전반의 내부 회로 인 부스 바는 충전부의 노출로 인해 전기 사고의 원인이 되며 이로 인한 감전 사고와 단락 사고가 발생된다. 또한 동물 및 이물질 침투로 인한 전기 화재 사고가 발생되는 원인이 되기도 한다. 또한 확장이 불가능한 구조로 무리하게 연결하여 사용하므로 접촉 저항 증가 발생으로 과열 사고를 유발시키기도 하며, 절단과 절곡 등의 제조 공정상의 어려움을 가지고 있기 때문에 주문생산방식을 택할 수밖에 없는 현실이며, 긴급전기 사고 발생시 복구하는데 지연되는 원인이 되기도 한다. 본 논문에서는 이와 같은 문제점을 개선하기 위해서 분 배전반의 모선을 절단하여 개별 블록으로 절연 난연 케이스와 격벽 구조화로 안전성을 높여 모듈 블록화 하였으며, 확장성과 유연성을 구현하였으며, 쉽게 확장이 가능한 구조이며, 또한 쉽게 분 배전반을 조립할 수 있다는 것이며, 이와 같이 전기적 위험 요소를 제거한 전기 분 배전반의 내부 구조는 블록형 부스 바 구조를 가지고 메인차단기와 분기차단기간의 회로 형성 구현 방식의 분 배전반를 제안하고 공인시험기관의 시험을 통해 그 유용성을 입증 하였다.

기후환경 변화에 따른 전기재해 위험도 분석 (Analysis and Risk Prediction of Electrical Accidents Due to Climate Change)

  • 김완석;김영훈;김재혁;오훈
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.603-610
    • /
    • 2018
  • 본 산업의 발달 및 화석연료 사용 증가로 인하여 지구온난화 및 기후변화가 가속화되어 기존보다 강도 높은 자연재해가 빈번하게 발생하고 있다. 전기시설물은 옥외에 시설된 경우가 많아 자연재해에 큰 영향을 받아 전기설비 관련 사고가 증가하는 추세이다. 본 논문에서는 국내의 기후변화에 따른 전기화재, 감전사고 및 전기설비사고의 통계 현황을 분석하여 기후변화와 연계한 위험도를 제시한다. 또한, 다양한 지역 별(광역시) 기후조건(온도, 습도)과 연계한 전기재해 데이터 분석을 통하여 각 지역의 월별 전기화재 위험도 분석 모델을 제시하고, 저압, 고압 설비의 자연재해에 대한 사고 위험도를 분석한다. 이러한 지역별, 설비별 위험도 분석 모델을 통하여 기초적인 전기재해 예측 모델을 제시하였다. 따라서 제시한 분석 데이터를 활용하여 향후 각 지역 및 전기설비를 대상으로 전기재해 위험도 예측 맵을 웹사이트나 스마트폰 앱을 통하여 전기안전 서비스를 제안할 수 있으며, 기후변화의 따른 자연재해에 대한 전기사고를 미연에 방지하기 위한 내성기준이나 전기설비의 내구성을 증가시키기 위한 노력이 필요하다.

전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구 (A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires)

  • 황진권
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2009
  • 전류 돌입형, 비선형 및 전류 단속형 부하들은 정상작동 상태에서 아크 발생의 경우와 유사한 전류파형을 갖는다. 이러한 부하들에서 아크 검출기법을 정확하게 구현하기 위하여서는 아크 유무에 따른 전류파형의 전형적인 특징을 찾을 필요가 있다. 본 논문에서는 UL 1699의 직렬과 병렬 아크 발생장치들로 이러한 부하들에 마크를 발생시키고 시간 및 주파수 영역에서 아크 전류파형을 분석한다. 아크 실험의 분석결과를 통하여 아크 전류파형의 전형적인 특징은 시간영역에서는 영점전류의 처짐 현상이고 주파수영역에서는 60Hz 고조파 성분을 제외한 전대역의 주파수에 걸쳐서 스펙트럼 크기가 증가되는 것임을 보인다. 비선형 및 전류 단속형 부하들에서 시간영역보다는 주파수영역의 아크 전류의 특징이 보다 명확히 나타남을 보인다. 본 논문에서 제시된 아크 전류파형의 특징들은 아크 차단기 개발을 위한 기반자료로 활용될 것으로 기대된다.

아산화동증식 발열에 의한 화재 사례의 분석 (Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding)

  • 박진영;이의평
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.54-63
    • /
    • 2020
  • 전선 접속부 등에서 아산화동(Cu2O)증식 발열에 의해 화재가 발생하는 것은 화재조사 전문가들에게 널리 알려져 있지만 아산화동증식 발열에 의한 화재사례를 구체적으로 분석하여 소개하는 논문은 거의 없다. 이 논문에서는 전기적인 접속부분의 발열에 의한 화재 통계와 아산화동증식 발열 현상과 특징을 분석한 후 아산화동증식 발열에 의해 대학실험실의 전선 접속부분에서 화재가 발생한 사례에 대해 구체적으로 분석하고 있다. 이 화재사례는 발화개소의 화재패턴 조사, 전선 접속부분에 대한 육안 조사, 3차원 CT 촬영 조사, 전원인가 시험, 실체현미경 조사, SEM과 EDS 분석을 통해서 전선 접속부분에서 아산화동 증식 발열로 인해 화재가 발생한 것으로 결론을 내릴 수 있었다.

BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석 (Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System)

  • 조석환;고재섭;김대경
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.