• Title/Summary/Keyword: The 3D image

Search Result 5,074, Processing Time 0.036 seconds

A Study on the Shallow Marine Site Survey using Seismic Reflection and Refraction Method (탄성파 반사법 및 굴절법을 이용한 천해저 지반조사에 대한 연구)

  • Shin, Sung-Ryul;Kim, Chan-Su;Jo, Churl-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.109-115
    • /
    • 2008
  • It is very important to estimate the physical properties of survey area and delineate the geological basement in marine site survey for the design of offshore structures. For the purpose of providing high quality data by means of engineering site survey, it is necessary to apply several survey techniques and carry out the integrated interpretation to each other. In this study, we applied single channel seismic reflection method and OBC (Ocean Bottom Cable) type seismic refraction method at shallow marine. We used a dual boomer-single channel streamer as a source-receiver in seismic reflection survey and airgun source-the developed OBC type streamer in seismic refraction survey. We made 24 channels OBC type streamer which has 4m channel interval and each channel is composed of single hydrophone and preamplifier. We tested the field applicability of the proposed method and applied the typical seismic data processing methods to the obtained reflection data in order to enhance the data quality and image resolution. In order to estimate the geological velocity distribution from refraction data, seismic refraction tomography technique was applied. Therefore, we could successfully perform time-depth conversion using the velocity information as an integrated interpretation. The proposed method could provide reliable geologic information such as sediment layer thickness and 3D basement depth map.

Comparison of Storage Stability, Volatile Compounds and Sensory Properties between Coarsely-and Finely-Marbled 1+ Grade Hanwoo Beef Loins

  • Cho, Soohyun;Lee, Wangyeol;Seol, Kuk-Hwan;Kim, Yunseok;Kang, Sun Moon;Seo, Hyunwoo;Jung, Younbok;Kim, Jinhyoung;Ba, Hoa Van
    • Food Science of Animal Resources
    • /
    • v.40 no.4
    • /
    • pp.497-511
    • /
    • 2020
  • This study aimed at comparing the storage stability, fatty acids profile, volatile flavor compounds and eating quality of Hanwoo beef longissimus thoracis (LT) muscles between two marbling morphological groups (fineness and coarseness). The 1+ grade Hanwoo LT muscles were measured for marbling fleck morphology at the 13th thoracic vertebrae location by using computerized image analysis. Results reveal that both marbling groups had similar proximate composition (protein, fat, moisture and collagen), color and technological quality traits (p>0.05). However, the coarse marbling group presented greater C18:2n6 and polyunsaturated fatty acids contents compared to the fine marbling group (p<0.05). Furthermore, the fine marbling group presented lower volatile basic nitrogen (VBN) and 2-thiobarbituric acid reactive substance (TBARS) contents compared to the coarse marbling group after 14 d storage (p<0.05). Also, higher amounts of C18:2n6 oxidation-derived volatile compounds such as hexanal and 3-ethyl-2-methyl-1,3-hexadiene, were found in the coarse marbling group. In term of sensory aspects, the finely-marbled group received higher scores of flavor and taste compared to the coarse marbling group (p<0.05). Overall, the marbling flecks morphology partially showed its effects on the storage stability, fatty acids profile and eating quality of the 1+ grade Hanwoo beef LT muscle.

Analysis of Eye-safe LIDAR Signal under Various Measurement Environments and Reflection Conditions (다양한 측정 환경 및 반사 조건에 대한 시각안전 LIDAR 신호 분석)

  • Han, Mun Hyun;Choi, Gyu Dong;Seo, Hong Seok;Mheen, Bong Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.5
    • /
    • pp.204-214
    • /
    • 2018
  • Since LIDAR is advantageous for accurate information acquisition and realization of a high-resolution 3D image based on characteristics that can be precisely measured, it is essential to autonomous navigation systems that require acquisition and judgment of accurate peripheral information without user intervention. Recently, as an autonomous navigation system applying LIDAR has been utilized in human living space, it is necessary to solve the eye-safety problem, and to make reliable judgment through accurate obstacle recognition in various environments. In this paper, we construct a single-shot LIDAR system (SSLs) using a 1550-nm eye-safe light source, and report the analysis method and results of LIDAR signals for various measurement environments, reflective materials, and material angles. We analyze the signals of materials with different reflectance in each measurement environment by using a 5% Al reflector and a building wall located at a distance of 25 m, under indoor, daytime, and nighttime conditions. In addition, signal analysis of the angle change of the material is carried out, considering actual obstacles at various angles. This signal analysis has the merit of possibly confirming the correlation between measurement environment, reflection conditions, and LIDAR signal, by using the SNR to determine the reliability of the received information, and the timing jitter, which is an index of the accuracy of the distance information.

The Evaluation on Accuracy of LiDAR DEM by Plotting Map (도화원도를 이용한 LiDAR DEM의 정확도 평가)

  • 최윤수;한상득;위광재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.2
    • /
    • pp.127-136
    • /
    • 2002
  • DEM(Digital Elevation Model) is used widely in image processing, water resources, construction, GIS, landscape architecture, telecommunication, military operations and other related areas. And it is used especially in producing ortho-photo based on specific DEM and developing 3D GIS database vividly. As LiDAR(Light and Detection And Ranging) system emerged recently, DEM could be developed in urban area more efficiently and more economically, compared to the conventional DEM Production. Traditional method using check points for elevation has tome limitations in structure's height accuracy by LiDAR, because it uses only terrain height. Accordingly after the downtown of Chungju city was selected as a test field in this paper and DEM and digital ortho images was produced by way of LiDar survey, the accuracy was evaluated through analytical plotting map. The result shows that in case of buildings in LiDAR DEM, the accuracy is 0.30 m in X, 0.62 m in Y and RMS is 1.17 m. The difference distribution between DEM and plotting map in range of $\pm$10 cm was 36.2% and $\pm$10 cm $\pm$20 cm was 43.53%. The accuracy of LiDAR in this study meets 1/5,000 which is the regulation for map of NGI(National Geography Institute) and LiDAR can be possibly used in many other applied area.

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

A Study on the Necessity and Applicability of Interactive Electronic Technical Manual(IETM) for Construction Projects (건설분야 전자매뉴얼의 필요성 및 특성분석을 통한 실무적용성 연구)

  • Kang, Leen-Seok;Jung, Won-Myung;Kwak, Joong-Min
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.1 s.23
    • /
    • pp.99-108
    • /
    • 2005
  • Interactive electronic technical manual(IETM) for construction projects means an electronic tool that regulations and specifications related to construction method or maintenance process ale described by electronic book type. It has a meaning of integrated information system that includes virtual reality(VR), 3D animation and image contents for representing real construction information so that user can easily understand the construction situation and maintenance process. The basic information and technical manuals of construction facilities are being written as paper documents in our construction industry. As the result, the information management in the maintenance phase of construction projects is inefficient, and maintenance cost is being increased. This study attempts to improve the lack of understanding about construction IETM through the analysis of necessity and unique function of construction IETM comparing with the IETMS in other industry, Finally, this study shows a scenario of construction IErM for mitigating natural disaster of construction facilities to verify applicability of IETM.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging (전자포탈영상을 이용한 다엽시준기의 정도관리)

  • ;Jason W Sohn
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.151-160
    • /
    • 2003
  • The application of more complex radiotherapy techniques using multileaf collimation (MLC), such as 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT), has increased the significance of verifying leaf position and motion. Due to thier reliability and empirical robustness, quality assurance (QA) of MLC. However easy use and the ability to provide digital data of electronic portal imaging devices (EPIDs) have attracted attention to portal films as an alternatives to films for routine qualify assurance, despite concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In this study, we developed method for daily QA of MLC using electronic portal images (EPIs). EPID availability for routine QA was verified by comparing of the portal films, which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed two-test patterns of dynamic MLC were applied for image acquisition. Quantitative off-line analysis using an edge detection algorithm enhanced the verification procedure as well as on-line qualitative visual assessment. In conclusion, the availability of EPI was enough for daily QA of MLC leaf position with the accuracy of portal films.

  • PDF

Practical Applications of DNA Marker-Assisted Selection and OPU-Derived IVF Embryo Transfer for the Production of High Quality Meat in Hanwoo I. Collection of Follicular Oocytes with Ultrasound-Guided Transvaginal Ovum Pick-Up from DNA Marker-proved Hanwoo (유전자 분석을 통하여 선발된 한우로부터 초음파 유래 체외수정란 이식에 의한 고품질 한우 생산기술의 실용화 I. DNA 검정우에서 초음파기기를 이용한 난포란의 채란에 관한 연구)

  • 박희성;이지삼;진종인;박준규;홍승표;이명열;정장용
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.183-191
    • /
    • 2001
  • This study was designed to establish the superior method for IVF embryos from DNA marker-proved Hanwoo cattle. DNA markers related to marbling score were identified using DNA fingerprinting with Ml3 probe and restriction enzyme Hae III. Oocytes were aspirated from unstimulated. immature ovarian follicles using a combined method of rectal ovarian-palpation and transvaginal ultrasound-guidance(6.5MHz) under local abesthesia. The aspirated oocytes were washed twice with fresh D-PBS containing 5% FBS and were rewashed 4 to 5 times with TCM-199 containing 5% FBS. A morphological grade of I to IV was assigned to each oocyte. Data were analysed using the GLM procedure of SAS. Mean number of follicles identified on ultrasound was 5.5 $\pm$2.9 in right and 4.3 $\pm$2.8 in left ovaries, respectively. The highest follicles(16.6$\pm$2.6) were found in 5101 cow compared to others. Recovery rate of follicular oocytes in individual cow was highest in 5101 cow with 89.3% in > 2mm and 94.0% in $\leq$ 2mm follicles. Total recovery rate was significantly(P<0.01) higher in $\leq$ 2mm(85.7%, 130/154) than > 2mm follicles(74.2%, 201/271). Significantly more oocytcs of Grade IV were recovered from > 2mm follicles. Mean number follicles recovered was 4.8$\pm$3.7. 3.0$\pm$3.4 and 0.3$\pm$0.6 in $\leq$2mm, 2~6mm and $\geq$6mm follicles. respectively. Our results imply that the more fertilizablc oocytes can be recovered from invisible-immature follicles by the combination of simultaneous rectal ovarian-palpation and ultrasound-guided approach in Hanwoo cattle.

  • PDF

An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragment (정맥내 카테터 조각의 엑스선, 초음파 및 CT 영상의 실험적 비교 연구)

  • Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.185-191
    • /
    • 2016
  • The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon$^{(R)}$ IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose ($0.2139mSv{\cdot}Gy^{-1}{\cdot}cm^{-2}$) form DAP DAP ($0.93{\mu}Gy{\cdot}m^2 $), and dose length product (DLP) ($201mGy{\cdot}cm$) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.