• 제목/요약/키워드: Textile Sensor

검색결과 113건 처리시간 0.025초

Research Trends on Healthcare Wearables Published in Korean Journals

  • Kim, Nam Soon;Do, Wol Hee
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.607-616
    • /
    • 2020
  • Health care wearables are devices that are attached to or combined with the human body to improve the health care capabilities of the human body that can be safely and adjustable according to preference. This study provided direction for future research on healthcare wearables in the field of clothing science, considering trends observed in this field from 2010 to 2019. Over the last 10 years, 812 studies have been conducted on healthcare wearables in Korea. Research has increased significantly since 2015, with a large number of articles published in this field. The research for this study was broken down into the following categories: technology development, marketing analysis, and technology analysis. The results according to the research method demonstrated that development and production methods were used most frequently, followed by trend analysis, experiment and evaluation, and survey. An analysis of keywords in the articles studied revealed that device, healthcare, big data (biometric data and database), and healthcare convergence technologies were trending. Similarly, detailed research on healthcare wearable devices and related technologies was actively being conducted. However, focusing on fiber, textiles, design, and clothing articles, in relation to the field of clothing in healthcare wearables, only 81 articles were found on this topic (10.0%), which was low compared to other studies. Therefore, it was determined that more research on healthcare wearables is necessary in the field of clothing.

Poly(dimethylsiloxane) 미세 구조물의 신속한 기하학적 패터닝 (Rapid Topological Patterning of Poly(dimethylsiloxane) Microstructure)

  • 김보열;송환문;손영아;이창수
    • 한국염색가공학회지
    • /
    • 제20권1호
    • /
    • pp.8-15
    • /
    • 2008
  • We presented the modified decal-transfer lithography (DTL) and light stamping lithography (LSL) as new powerful methods to generate patterns of poly(dimethylsiloxane) (PDMS) on the substrate. The microstructures of PDMS fabricated by covalent binding between PDMS and substrate had played as barrier to locally control wettability. The transfer mechanism of PDMS is cohesive mechanical failure (CMF) in DTL method. In the LSL method, the features of patterned PDMS are physically torn and transferred onto a substrate via UV-induced surface reaction that results in bonding between PDMS and substrate. Additionally we have exploited to generate the patterning of rhodamine B and quantum dots (QDs), which was accomplished by hydrophobic interaction between dyes and PDMS micropatterns. The topological analysis of micropatterning of PDMS were performed by atomic force microscopy (AFM), and the patterning of rhodamine B and quantum dots was clearly shown by optical and fluorescence microscope. Furthermore, it could be applied to surface guided flow patterns in microfluidic device because of control of surface wettability. The advantages of these methods are simple process, rapid transfer of PDMS, modulation of surface wettability, and control of various pattern size and shape. It may be applied to the fabrication of chemical sensor, display units, and microfluidic devices.

동잡음을 가진 PPG 센서에서의 산소포화도 측정 알고리즘 (SpO2 Measurement Algorithm for PPG Signal with Motion Artifacts)

  • 장성진;최규락;박근혜;김정도
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.192-198
    • /
    • 2018
  • Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it because Masimo's patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The proposed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.

활성탄소섬유의 비표면적에 따른 유해가스 흡착 및 전기화학적 감응 특성 (Effect of Specific Surface Area of Activated Carbon Fiber on Harmful Gas Adsorption and Electrochemical Responses)

  • 강진균;정용식;배병철;류지현
    • 접착 및 계면
    • /
    • 제21권2호
    • /
    • pp.51-57
    • /
    • 2020
  • 최근 산업활동을 통해 배출되는 유해 오염물질 제거에 대한 관심이 증가하고 있다. 본 연구에서는 수증기 활성화 법을 이용하여 활성탄소섬유를 제조하고, 이의 유해가스 흡착 및 전기화학적 감응 특성을 분석하였다. 활성탄소섬유의 균일한 기공 구조, 활성 반응 면적 및 반응 위치를 조절하기 위하여, 활성화 온도(750-850 ℃) 및 활성화 시간(30-240 min)을 조절하였고, 다양한 활성화 조건을 통해 제조된 활성탄소섬유의 SO2와 NO 가스 흡착 및 가스 센서를 통한 감응 특성을 분석하였다. 특히, 850 ℃에서 45 min동안 수증기 활성화 반응을 통해 제조된 활성탄소섬유가 가장 높은 비표면적(1,041.9 ㎡/g)과 기공 특성(0.42 ㎤/g)을 보였으며, 우수한 SO2 (1.061 mg/g) 및 NO (1.210 mg/g) 가스 흡착 특성을 보였다.

마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구 (A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor)

  • 이강휘;이성수;이정환;송하영
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.

그래핀 옥사이드의 에어로졸 분무열분해 공정을 통한 면직물의 전기전도성 및 물성 평가 (Application and Functionalization of Graphene Oxide on Cotton Fabric Via Aerosol Spray Pyrolysis)

  • 엄현지;조길수
    • 한국의류산업학회지
    • /
    • 제24권1호
    • /
    • pp.138-145
    • /
    • 2022
  • Today, graphene loaded textiles are being considered promising smart clothing due to their high conductivity. In this study, we reported reduced graphene oxide(r-GO) deposited pure cotton fabrics fabricated with a colloidal solution of graphene(GO), using a one-step aerosol spray pyrolysis(ASP) process and their potential application on smart textiles. The ASP process is advantageous in that it is easily implementable and can be applied for continuous processing. Moreover, this process has never been applied to deposit r-GO on pure cotton fabric. The field emission-scanning microscopy (FE-SEM) observation, Fourier transform-infrared(FT-IR) analysis, Raman spectroscopy, X-ray diffraction(XRD) analysis, and ultraviolet transmittance(UVT) were used to evaluate material properties of the r-GO colloids. The resistance was also measured to evaluate the electrical conductivity of the specimens. The results revealed that the r-GO was successfully deposed on specimens, and the specimen with the highest electrical conductivity demonstrated an electrical resistance value of 2.27 kΩ/sq. Taken together, the results revealed that the ASP method demonstrated a high potential for effective deposition of r-GO on cotton fabric specimens and is a prospect for the development of conductive cotton-based smart clothing. Therefore, this study is also meaningful in that the ASP process can be newly applied by depositing r-GO on the pure cotton fabric.

폴리아크릴로니트릴 기반 3D 탄소나노섬유 스펀지의 제조 및 오일 흡착 특성 (Preparation and Oil Absorption Properties of PAN Based 3D Shaped Carbon Nanofiber Sponge )

  • 주혜원;강진혁;박종호;고재경;국윤수;남창우;김병석
    • Composites Research
    • /
    • 제36권3호
    • /
    • pp.217-223
    • /
    • 2023
  • 본 연구에서는 폴리아크릴로니트릴계 탄소나노섬유 스펀지의 제조 및 오일 흡착 거동을 조사하였다. 제조된 탄소나노섬유 스펀지는 물과 기름의 혼합용액에서 우수한 선택적 오일 흡착 능력을 보였으며, 탄소나노섬유 스펀지의 재사용시 흡착 능력도 확인하였다. 또한, 흡착제 내부구조에 정렬된 채널을 형성함으로써, 모세관 현상에 의하여 빠른 오일 흡착 거동을 보이는 탄소나노섬유 스펀지를 제조할 수 있었다. 이후 사용 폐기된 탄소나노섬유 스펀지는 질소 분위기에서 800℃로 열처리하여, 4-아미노페놀의 전기화학적 검출을 위한 센서로의 가능성을 검토하였다.

근활성도(EMG) 측정 전극 레이어 설계에 따른 성능 및 안정성 평가 (Performance and Stability Evaluation of Muscle Activation (EMG) Measurement Electrodes According to Layer Design)

  • 구본학;이동희;김주용
    • 감성과학
    • /
    • 제26권4호
    • /
    • pp.41-50
    • /
    • 2023
  • 본 연구는 EMG(electromyography) 텍스타일 전극 개발을 목적으로 레이어 수의 디자인 및 원단을 다르게 하여 성능 및 신호 획득 안정성을 평가한다. 레이징 및 프레스 공정을 통하여 텍스타일 전극을 제조하며 Layer-0, Layer-1, Layer-2로 레이어 유무 및 수에 따른 결과를 분석했다. 이에 레이어 유무에 따라서는 근활성 측정에 영향을, 수가 많을수록 높은 성능이 나타남을 확인할 수 있었다. Layer-2 구조로 통일하여 5가지의 원단(네오프렌, 스판덱스 쿠션, 폴리에스테르 100%, 나일론 스판덱스, 광목 캔버스)으로 전극을 제조해 실험해 보았다. 성능적인 면에서, 원단의 중량이 높은 나일론 스판덱스가 높은 성능을 보였으며, 스판쿠션 텍스타일 전극이 근활성도 수득에 높은 안정성을 보였다. 이에 위 연구는 레이어에 따른 성능 연관성과 전극-피부사이의 닿는 면적 간의 관계 등을 고찰하여 슬리브 전체의 의복압을 늘리는 대신 특정 센서 측정 부위에만 높은 압력을 가함으로 차후 연구에서 레이어의 수 및 물성에 따른 전극의 공학적 설계 가능성을 제시한 의의가 있다.

센서 기반형 스마트 의류의 디자인 개발을 위한 탐색적 연구 - 생체 신호 센서 기술에 기반한 건강관리용 의류를 중심으로 - (An Exploratory Research for Development of Design of Sensor-based Smart Clothing - Focused on the Healthcare Clothing Based on Bio-monitoring Technology -)

  • 조하경;이주현;이충근;이명호
    • 감성과학
    • /
    • 제9권2호
    • /
    • pp.141-150
    • /
    • 2006
  • 1990년대 후반 이후 스마트 의류는 인간과 컴퓨터의 상호작용, 사용자 중심의 디자인 등 다각적으로 연구, 개발되고 있다. 최근에는 보다 기능화, 감성화된 스마트 의류가 개발되기 시작하였으며, 이는 다양한 어플리케이션으로 연구, 개발되어 제시되고 있다. 그 중 센서를 기반으로 한 건강관리용 스마트 의류는 스마트 의류의 여러유형 중 가장 예상 수요가 높은 유형으로 예측되며, 이러한 전망으로 인해 연구, 개발이 가속화되고 있는 분야이다. 이에 따라 본 연구에서는 스마트 의류에 적합한 생체 신호 센서를 도출하고, 그를 기반으로 기본적인 생체신호, 심장질환, 호흡기 질환을 측정할 수 있는 스마트 의류 디자인을 개발하였다. 즉, 본 연구에서 개발된 스마트의류는 기존의 의류의 외관 형태는 그대로 유지하면서, 직물 신호선을 제작, 와이어의 이물감을 없애 착용성을 높였으며, 착장 시 생체신호가 컴퓨터로 무선 전송되어 이를 실시간으로 모니터링 할 수 있도록 고안되었다. 이 스마트 의류는 생체 신호 센서를 이용하여 심장질환, 호흡기 질환과 다양한 질병 예방을 보조할 수 있는 건강관리용 의류로서 센서기반 스마트 의류의 한 모형을 제시하였다.

  • PDF

브래지어 총(總) 길이 적합성(適合性)에 관(關)한 연구(硏究)(II) (A Study on the adaptedness of brassiere underbust length)

  • 박유신;최영순
    • 패션비즈니스
    • /
    • 제10권1호
    • /
    • pp.31-40
    • /
    • 2006
  • We studied relation between the clothing pressure applied by types of brassiere, postures, feeling of tightness. The main results were summerized as follows; 1. The research subjects of this study were 9 who rate of body fat was borderline and degree of fatness was normal. As a result of clothing pressure, the most prefered value was $36.86g/cm^2$ on sensor 2 in standing position and the next was $34.76g/cm^2$ on sitting position. Furthermore, The maximum value of sensor 2 was $59.08g/cm^2$ (in standing), $57.93g/cm^2$ (in sitting). On the other hand, The average clothing pressure of bra C type was $23.67g/cm^2$ 2. The study of feeling of tightness applied by bra type was high in order of C