• Title/Summary/Keyword: Testing Standards

Search Result 750, Processing Time 0.02 seconds

A Study on the Temperature Environmental Test Standards (온도 환경시험 표준규격에 관한 연구)

  • Lee Kwan-Hun;Kim Joon-Won
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.421-430
    • /
    • 2005
  • The required standards for environmental tests for communication and electronic equipment used currently are not standards into which the Korean climate and use environment are taken into consideration. But the most used environmental testing standards of the U.S. army(MIL-STD-810) has been used without taking into consideration the Korean domestic situation and conditions by simply translating the US standards. Adherence to these standards may increase in the manufacturing costs according to excessively strict standards. Therefore, this paper will propose a new environmental test standards for temperature.

  • PDF

Characteristics of Magnetostrictive Sensor for Detecting the Flaws in Pipe (배관결함 검출을 위한 자왜형 초음파 센서의 특성)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.46-53
    • /
    • 2000
  • Magnetostrictive sensors which can be used effectively to detect flaws in pipe were fabricated. The optimal conditions to obtain the maximum generation efficiency of the ultrasonic wave were established. In case of the used steel pipe the optimal magnetic field was $250{\sim}350Oe$ and the coil width of 15mm showed the best efficiency for generating a wave with the frequency of 180 kHz. In the best condition, the wave can propagate further than 50m without serious attenuation. The amplitude of the ultrasonic wave reflected from artificial flaw had a good linear relationship to the cross-sectional area of the flaw.

  • PDF

Pipe Wall Thinning Evaluation through the Arrival Time Delay of A0 Lamb Wave Using Magnetostrictive Patch Transducers

  • Cho, Seung-Hyun;Kwon, Hyu-Sang;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.512-518
    • /
    • 2008
  • Guided wave technology is advantageous for fast inspection of pipe wall thinning since the guided wave propagates long distance. In this investigation, the method to evaluate gradual wall thinning in a pipe based on the arrival time delay with magnetostrictive patch transducers is presented. Low frequency A0 Lamb waves were generated and measured by the present transducer and it was applied to arrival time delay measurement experiments on a test pipe having gradual wall thinnings artificially manufactured. From experiments, consistent results that wall thinning increases the arrival time delay of A0 waves were obtained. Consequently, the feasibility of the magnetostrictive patch transducers to evaluate wall thinning was verified.

A Study on the International Standard and Regulation for Electric Motor and Drives (전동기와 드라이브의 국제 규격 및 규제에 관한 현황 연구)

  • Woo, Kyung-Il;Park, Han-Seok;Kim, Dea-Kyong;Choi, Han-Seok;Jun, Hee-Deuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.437-443
    • /
    • 2014
  • Electric motors and drives consume the largest amount of electricity more than 40% of global electricity consumption. In addition, motors, drives and its components are included in the global high-trade products and the main driving source for industrial equipment and house appliances. Thus, International standards and regulations for their safety and efficiency are internationally being discussed and created for the protection of its citizens and energy saving. So, understanding the international standards and the regulation of each country is essential to enhance overseas market and to develop product. In this paper, on the basis of this background, status and trends of international standards and regulations are introduced for safety and efficiency of motors and the drives. Safety and efficiency of the IEC (International Electrotechical Commission) standards are introduced in the emphasis. Also, regulations are studied about the differences and trends in each county.

Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards (국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구)

  • Namkoong Chai-Kwan;Kong Jae Hyang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

Development of Comparative Calibration System for Helium Leak Standard by Using Mass Spectrometer Type Leak Detector (질량분석기형 누출검출기를 이용한 헬륨투과형 표준 누출 비교 교정 장치 개발)

  • Hong, Seung-Soo;Lim, In-Tae;Kim, Jin-Tae;Shin, Yong-Hyeon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.151-156
    • /
    • 2008
  • Many kinds of mass spectrometer type leak detectors have been widely used for detecting leak of vacuum processes in semiconductor and display industries etc. The leak detectors should be often calibrated by the permeation type standard leak in order to ensure accurate and reproducible leak measurement. We have developed a comparative calibration system for permeation type standard leak by using mass spectrometer type leak detector and specification of the calibration method. Following this technique the reliable calibration for leak standard ran be performed even in fields.

Infrared Thermography Characterization of Defects in Seamless Pipes Using an Infrared Reflector

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Jea-Jung;Kim, Won-Tae;Lee, Bo-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.284-290
    • /
    • 2012
  • Infrared thermography uses infrared energy radiated from any objects above absolute zero temperature, and the range of its application has been constantly broadened. As one of the active test techniques detecting radiant energy generated when energy is applied to an object, ultrasound infrared thermography is a method of detecting defects through hot spots occurring at a defect area when 15~100 kHz of ultrasound is excited to an object. This technique is effective in detecting a wide range affected by ultrasound and vibration in real time. Especially, it is really effective when a defect area is minute. Therefore, this study conducted thermography through lock-in signal processing when an actual defect exists inside the austenite STS304 seamless pipe, which simulates thermal fatigue cracks in a nuclear power plant pipe. With ultrasound excited, this study could detect defects on the rear of a pipe by using an aluminium reflector. Besides, by regulating the angle of the aluminium reflector, this study could detect both front and rear defects as a single infrared thermography image.

A Review of Current Status and Applications of Korean Industrial Standards (KS) on the Floor Slip Resistance Testing (바닥의 미끄럼 시험에 관한 한국산업표준(KS) 현황 및 적용 실태)

  • Baik, Kwon-Hyuk;Ji, Suk-Won;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.19-20
    • /
    • 2021
  • Although various laws and regulations have been put in place to prevent slips and falls, many accidents still occur. In this study, the root cause of slips and falls not decreasing were investigated. There are five types of slip resistance test methods in the Korean Industrial Standards (KS). Namely, KS F 2375:2016, KS F 2601:2020, KS F 2602:2016, KS L 1001:2020, and KS G 5821-1:2020 are listed. These test methods are cited in building certification standards (BF and G-SEED), construction specifications, and other documents that specify slip safety criteria. As a result of the investigation, a number of errors in KS regulations and legal text, errors in the manufacture and operation of slip testers, and errors in the use of measured values were found. These errors threaten the public life safety and disrupt industrial sites, and must be corrected immediately.

  • PDF

Test Process Execution Tool: Test PET (테스트 프로세스 수행 도구)

  • 천은정;최병주
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.2
    • /
    • pp.125-133
    • /
    • 2004
  • In order to test reflecting the features of a development methodology and domain, it is required to tailor process standards and perform testing according to the tailored process. However, since commercial testing tools support only a part of the tailored process, it is essential to either acquire or develop testing tools appropriate for a development environment. This paper proposes a method to develop a test process execution tool which has common features of standards, and variousness in methodologies and domains. ‘Test Process Execution Tool: Test PET’ which is a test process execution tool developed adapting the concept of product line. Our Test PET generates the test process suitable for the development methodology and domain and then executes the produced test process.

A Study on a Small-scale Wastewater Treatment System Using MBR and IPNR (MBR과 IPNR을 이용한 소규모 하수처리 시스템에 관한 연구)

  • Kim, Young-Hee;Jo, Eun-Young;Yeo, In-Seol;Park, Seung-Min;Park, Chan-Gyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2015
  • In the purpose of this study, we investigate the characteristics of the pilot-scale wastewater treatment system applied to BAF, MBR and IPNR as examining the removal efficiency of organic pollutants and operating factors in small decentralized wastewater treatment systems, and operating factors. For long-term operation period of more than nine months, pilot-scale plant operating results appeared very stable. This results were the removal efficiency of BOD was 80.3% above and removal efficiency of COD with an average of about 91.0%, satisfied the final effluent water quality standards. TN in the final effluents was the average concentration of 7.9 mg/L, was satisfactory water quality standards 10 mg/L of TN.