• Title/Summary/Keyword: Testing Method

Search Result 5,903, Processing Time 0.039 seconds

Design and Characteristics Analysis of the 78 kWe Grade Synchronous Generator for Disused Diesel Engines

  • Youn, Jun-Seop;Kim, Hae-Joong;Kim, Youn-Hwan;Moon, Jae-Won
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.122-132
    • /
    • 2017
  • This study dealt with the design process of the 78 kW permanent magnet synchronous generator for engines. After the calculation of the basic dimensions through a theoretical method in the process of initial model design, FEA (finite-element analysis) and a d,q-axis equivalent circuit were used to identify the generator characteristics depending on the number of poles. With the use of the space harmonic analysis method, the back-EMF (electromotive force) and THD were checked, and then the number of slots was determined. In addition, the most optimized generator dimensions were determined through a sizing optimization technique. Based on this, the optimum model with enhanced efficiency, material costs, and temperature characteristics was derived, and the availability of the design method was confirmed through a comparative analysis of the initial and optimum models.

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

Importance Analysis of In-Service Testing Components for Ulchin Unit 3 Using Risk-Informed In-Service Testing Approach

  • Kang, Dae-il;Kim, Kil-yoo;Ha, Jae-joo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.331-343
    • /
    • 2002
  • We performed an importance analysis of In-Service Testing (157) components for Ulchin Unit 3 using the integrated evaluation method for categorizing component safety significance developed in this study. The developed method is basically aimed at having a PSA expert perform an importance analysis using PSA and its related information. The importance analysis using the developed method is initiated by ranking the component importance using quantitative PSA information. The importance analysis of the IST components not modeled in the PSA is performed through the engineering judgment, based on the expertise of PSA, and the quantitative and qualitative information for the 157 components. The PSA scope for importance analysis includes not only Level 1 and 2 internal PSA but also Level 1 external and shutdown/low power operation PSA. The importance analysis results of valves show that 167 (26.55%) of the 629 IST valves are HSSCs and 462 (73.45%) are LSSCs. Those of pumps also show that 28 (70%)of the 40157 pumps are HSSCs and 12 (30%) are LSSCs.

A Study on Automated Bluetooth Communication Testing Methods Using CSR8670 Chip

  • Kim, Young-Mo;Noh, Hyun-Cheol;Kim, Seok-Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.65-71
    • /
    • 2016
  • Bluetooth technology(BT) is a standard for short distance wireless communication and widely used to connect and control various electronic and telecommunication devices without wires, where CSR8670 chip is generally adopted. These BT devices are required to comply with BT specification and the equipments for conformance test are also important. However, the existing BT testing methods have inconvenience in that they are mostly time-consuming procedure due to not only repetitive execution for each evaluation element but also error-prone nature of manual experiments. This paper proposes an automated BT communication test method using CSR8670 chip, which solves the problems related to manual testing methods. The proposed method can reduce the development period of BT products and guarantee the quality improvement owing to the exact system error detection capability.

A Study on the Size Evaluation of Disc and Band Type Flaw by Ultrasonic Tandem Testing (초음파(超音波)TANDEM사각법(斜角法)에 의한 원형(圓形) 및 띠형결함(形缺陷)의 크기 평가(評價)에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Kim, J.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.12-21
    • /
    • 1986
  • Generally, butt welds with plate thickness $30{\sim}40mm$ are welded with groove angle $40^{\circ},\;60^{\circ},\;70^{\circ}$, etc. In the detection of internal weld defects, oblique testing with single probe has been mainly used. But, recently, in acccordance with enlargement of welded structure, thick plate with 100-200mm are frequently required. Thus I-groove welding method was lately developed and often used. In this case, most frequently generated defects are the lack of weld penetration and incomplete fusion between base metal and welding material. If we would detect by oblique testing with single probe, detecting flaw is occassionally impossible or very underestimated. In this study, the limit for applying tandem method was studied in dise and band type flaws. The estimation of flaw size could be within 10% error compared to real flaws.

  • PDF

A study on Analysis of Contact erosion at a Magnetic Contactor with the Use of Regression Analysis (회귀분석을 이용한 전자접촉기의 접점소모 분석에 대한 고찰)

  • Klm, Myoung-Seok;Ryu, Haeng-Su;Han, Gyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.116-118
    • /
    • 2003
  • This paper describes a Accelerated Life Test (ALT) with the electrical contact erosion suitable to the evaluations of high-reliability and durability devices such as magnetic contactor. Recently, an electrical devices company was interested in accelerated life test (ALT), the product liability (PL) and the short-term testing model of electrical life test (ELT). In order to estimate a model for testing fee and period, need to the statistical analysis method with the acceleration factor(AF). Usually customer/manufacturer regard their device failure to the over-current or heavy duty condition, while devices view shape of contact erosion owing to operational duty problem. In this paper, additional method of evaluation estimated the operated cycles by weight of contact erosion with a used of regression analysis by MINITAB.

  • PDF

Application of Accelerated Vibration Testing to Spot-welding Specimen (점용접 표준시편에 대한 가속내구시험법의 적용)

  • 김관주;조성신;정진성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.209-213
    • /
    • 2003
  • It is advantage of accelerated vibration testing to compress service exposures to operating vibration into a reduced laboratory test by increasing the amplitude or frequency of the applied input excitations. This paper proposes an accelerated test method to estimate the high-cycle fatigue life under random excitation. The method consists of conducting a test with amplified input excitation and extrapolating linearly the lift in the accelerated condition into the real lift in field condition. The extrapolation is carried out applying the high-cycle irregular excitation fatigue theory including the rainflow counting, Miner’s damage accumulation rule, and Goodman’s mean stress correction. As a verification, those estimated lift is compared with that acquired by experiment f3r the simple case of spot welding specimen with good agreement. This testing procedure will provide an useful scheme that can reduce testing period associated with developing time schedule of new product.

New Scan Design for Delay Fault Testing of Sequential Circuits (순차 회로의 지연 고장 검출을 위한 새로운 스캔 설계)

  • 허경회;강용석;강성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1161-1166
    • /
    • 1999
  • Delay testing has become highlighted in the field of digital circuits as the speed and the density of the circuits improve greatly. However, delay faults in sequential circuits cannot be detected easily due to the existence of state registers. To overcome this difficulty a new scan filp-flop is devised which can be used for both stuck-at testing and delay testing. In addition, the new scan flip-flop can be applied to both the existing functional justification method and the newly-developed reverse functional justification method which uses scan flip-flops as storing the second test patterns rather than the first test patterns. Experimental results on ISCAS 89 benchmark circuits show that the number of testable paths can be increased by about 10% on the average.

  • PDF

An Object-Oriented Redundant Fault Detection Scheme for Efficient Current Testing (전류 테스팅을 위한 객체 기반의 무해고장 검출 기법)

  • Bae, Sung-Hwan;Kim, Kwan-Woong;Chon, Byoung-Sil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1C
    • /
    • pp.96-102
    • /
    • 2002
  • Current testing(Iddq testing) on monitoring the quiescent power supply current is an efficient and effective method for CMOS bridging faults. The applicability of this technique, however, requires careful examination. Since cardinality of bridging fault is O($n^2$) and current testing requires much longer testing time than voltage testing, it is important to note that a bridging fault is untestable if the two bridged nodes have the same logic values at all times. Such faults should be identified by a good ATPG tool; otherwise, the fault coverage can become skewed. In this paper, we present an object-oriented redundant fault detection scheme for efficient current testing. Experimental results for ISCAS benchmark circuits show that the improved method is more effective than the previous ones.

Development of Evaluation Method for Drug Release Propreties in Drug Eluting Stent (약물방출스텐트의 약물 방출 특성 평가 방법 개발)

  • Song, J.M.;Baek, H.;Lee, S.Y.;Jang, D.H.;Seo, M.Y.;Park, G.J.;Maeng, Eun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.69-72
    • /
    • 2013
  • The goal of this study is to develop test method for evaluating the drug eluting properties of drug eluting stents (DES). PBS and the detergent solutions, presented by each DES manufacturer, were used for drug release of DES coated with paclitaxel, zotarolimus and everolimus. The drugs which are coating DES were not released by PBS but released by the detergent solutions, finally paclitaxel 83.38%, zotarolimus 103.85% and everolimus 115.78%. It seems that the use of the detergents is necessary in order to release the drugs because those drugs are extremely hydrophobic. In conclusion, using of detergent solutions presented by each manufacturer were suitable for evaluating the drug eluting property of drug eluting stent.