The Development of Straddle Packer Hydraulic Testing Equipment to Characterize Permeability in Deep Boreholes (장심도 시추공 정밀수리시험 장비 구축)

  • Kim, Kyung-Su;Park, Kyung-Woo;Ji, Sung-Hoon
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.213-220
    • /
    • 2010
  • The permeability characterization on the natural barrier for deep geological disposal of radioactive waste is very critical to evaluate total safety and performance assessment of disposal site. However, the confidence level in using previous hydraulic testing equipments consist of simple components to estimate rock mass permeability is not high enough to reflect in situ condition. The purpose of this research is to establish an advanced hydraulic testing equipment, which is applicable to deep borehole (up to 1,000 m), through the improvement of technical problems of previous packer systems. Especially, the straddle packer hydraulic testing equipment was designed to adopt both the hydraulic downhole shut-in valve(H-DHSIV) to minimize the wellbore storage effect and the real time data acquisition system to measure the pressure changes of test interval including its upper and lower parts. The results from this research lead to not only improve current technical level in the field of hydraulic testing but also provide important information to radioactive waste disposal technology development and site characterization project.

Construction of Efficient Downhole Seismic Testing System by the Round Robin Test (상호검증시험을 통한 효율적인 다운홀 탄성파 기법 수행 시스템의 구성)

  • Bang, Eun-Seok;Kim, Ki-Seog;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.133-147
    • /
    • 2007
  • Downhole seismic method is very economic and easy of operation because it uses only one borehole and simple surface source to obtain the shear wave velocity ($V_s$) profile of a site. Even though it is widely used by the site investigation companies, universities and institutes, however, the $V_s$ profile determined by downhole seismic method has often low reliability due to employment of wrong combinations of field losing equipment and interpretation method and deficiency of experience. Round robin test was performed and testing equipment and procedure were compared. Adequate downhole seismic testing equipment was constructed based on the comparison and verification study of the round robin test. The data acquisition and software interpretation were also developed for automation and quick test in field. Finally, the effectiveness and applicability were verified through the field test by using the constructed testing system.

Integrated Railway Signaling Systems for Laboratory Testing of Next-generation High-speed Train (한국형 고속전철용 신호시스템의 실험실 시험을 위한 통합 신호시스템)

  • Hwang, Jong-Gyu;Lee, Jong-Woo;Park, Yong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.32-39
    • /
    • 2004
  • Railway signaling systems consist of several vital computerized equipment such as CTC(Centralized Traffic Control), EIS(Electronic Interlocking System), ATC(Automatic Train Control) and so on. Currently, the project for development of railway signaling systems for the next-generation high-speed train is progressed according to the G7 project and railway signaling related several companies and research institute are joined this project consortium. The railway signaling systems, being developed in this project, called as a kTCS(Korean Train Control System), is composed of kTCS-CTC, kTCS-IXL, kTCS-ATC and etc. kTCS signaling systems have to be operated at the laboratory testing level as integrated signaling systems by interface between each railway signaling systems before railway field installation and revenue service. To solve this matter, communication protocols between each signaling equipment are designed and message codes for each defined protocols have defined. And also several equipment has developed for the railway integrated signaling systems for laboratory testing. We has plentifully tested and verified the designed protocols and the characteristics of integrated railway signaling systems with our developed each kTCS signaling equipment and communication protocols. In this paper, the integrated kTCS system including communication protocols is presented.

Design and fabrication of test equipment of RF Telecommand and Telemetry for satellite control (위성 제어용 RF Telecommand 및 Telemetry 시험 장비 설계 및 제작)

  • Chang, Lae-Kyu;Jo, Seong-Won;Lee, Hyung-Goo;Hong, Sung-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.187-192
    • /
    • 2009
  • Telecommand & telemetry control equipment is needed for the testing of the transponders during the development of satellite. This equipment must have a loopback function to perform the self testing without satellite. The fabrication of the designed system is easier and cheaper than the conventional testing system using direct modulation method. The measured results of fabricated equipment are satisfied with required specifications. A overall path loss of uplink and downlink is 47.8 dB and 42.6 dB, respectively. Also, IMD3 of uplink has measured 60.68 dBc at an output of -50 dBm.

The Development of Rhythmic Balance Training Equipment and its Effect on Performance for Elderly

  • Park, Da Won;Won, Cho Rong;Lee, Sung Ro;Park, Yang Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.323-331
    • /
    • 2016
  • Objective: The aims of this study were 1) to develop easy-to-use rhythmic balance training equipment for the elderly and 2) to investigate the effect of training with the equipment on balance and physical function. Method: Twenty-one elderly individuals (age: $75.4{\pm}3.34yrs$, height: $152.07{\pm}4.81cm$, weight: $58.35{\pm}8.34kg$) participated in this study. Each participant underwent balance and physical function testing before and after 12 weeks of training with the equipment. Y-balance (i.e. dynamic balance) and one leg static balance tests were used for balance testing, and timed up- and-down-stairs and five times sit-to-stand tests were used for physical function testing. A paired t test was used to determine whether there was a significant pre- and post-training difference. Results: The rhythmic balance training equipment provided a fun and motivating training program with age-friendly music, dance movements for lower extremity strength training, and touch screen controls with simple features. Post-training left foot dynamic balance was significantly greater (p<.05), and static balance with eyes open was significantly improved (p<.05) compared to pre-training. Completion of the timed up-and-down-stairs and the five times sit-to-stand tests was significantly shorter (p<.05) compared to pre-training. Conclusion: Training using the equipment developed in this study improved balance and physical function in elderly participants.

15,000psi Grade Control Systems Development for the Mud System in Offshore (해양 시추용 15,000psi급 머드 시스템에 대한 제어 시스템 개발)

  • Lee, Sang-Mok;Cho, Bae-Seok;Kim, Tae-Hyoung;Hwang, Jong-Deok;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.673-676
    • /
    • 2017
  • The Offshore drilling system of domestic drilling systems (drill rigs, drill ship) in Korea is dependent on full imports and the monopolistic situation of a few foreign large corporations is intensifying. In addition, most of domestic technology development tries to develop single product oriented products until now, but it is necessary to develop monitoring control system for package unit commercialization by approaching package development method. Therefore, we will develop a control monitoring system that can integrate the single equipment of the mud system developed previously.

  • PDF

Field Test and Analysis for Proper Location of Protective Equipment in Underground Distribution System (지중배전계통 보호설비 적정위치 선정을 위한 실증시험과 해석)

  • Yun, Chang-Sub;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.773-782
    • /
    • 2008
  • This paper describes the method for proper location of protective equipment in underground distribution cable through field test and analysis at testing lines. To prove the reliability for analysis simulated by EMTP/ATPDraw, the testing results obtained by the real test and the analysis for the same test lines were compared each other. The accuracy of analysis was proved by the comparison. Over voltages were measured and analyzed at each point of cable and switches in case of which lightning surge current was applied. The analysing method was applied to real distribution systems to select the proper location of protective equipment. It is evaluated that the location of protective equipment was properly selected.

Contribution of modification of a pressuremeter for an effective prediction of soil deformability

  • Aissaoui, Soufyane;Zadjaoui, Abdeldjalil;Reiffsteck, Philippe
    • Geomechanics and Engineering
    • /
    • v.23 no.4
    • /
    • pp.381-392
    • /
    • 2020
  • The difficulties, challenges and limitations faced in standard pressuremeter testing in the measurement of low soil deformations led a number of researchers to think about the possible modification of the equipment, and especially the replacement of the volumeter by a Hall Effect sensor. This article is a major contribution in this direction. It makes an attempt to detail the design, manufacture and operation of the new equipment. The calibration of the various components was carried out according to the rules presently in force. This proposal was applied, on an exploratory basis, to the data of a real site located in France. The authors present the preliminary results of some cyclic pressuremeter tests, previously carried out in the laboratory, on a sandy material, and they then provide a basic interpretation of these results. The findings indicated that the proposed apparatus is capable of providing high-quality information about constraints and deformations. Although these tests were performed within the laboratory, it was possible to analyze the power, quality, performance and insufficiencies of the proposed equipment.

Estimation of Uncertainty in Vibration Measurement of Shipboard Equipment (함정탑재장비 진동 측정불확도 추정)

  • Park, Sungho;Lee, KyungHyun;Han, HyungSuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.509-516
    • /
    • 2014
  • This paper proposes estimation model of uncertainty in vibration measurement of shipboard equipment and analyzes the result of uncertainty estimation. Vibration of shipboard equipments affects underwater radiated noise that is important performance related to stealth of the naval vessel. Acceptance testing for shipboard equipment is required to guarantee the stealth performance of naval vessel. In measuring, detailed uncertainty estimation is essential to improve measuring reliability. Acceptance testing result of structure-borne noise and vibration is used to analyze uncertainty in vibration measurement of shipboard equipment.

On-line and Off-line Partial Discharge Monitoring System with HVAC Testing (HVAC에 의한 On-line, Off-line PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF