• Title/Summary/Keyword: TestBed

Search Result 1,626, Processing Time 0.03 seconds

Developing a Test-Bed Toolkit for Scientific Document Analysis (기술 문헌 분석 테스트베드 툴킷 개발)

  • Choi, Sung-Pil;Song, Sa-Kwang;Jung, Han-Min
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.13-19
    • /
    • 2012
  • This paper introduces a test-bed toolkit for evaluating and enhancing text analysis engines which extract technological knowledge from articles, patents, reports and so forth. The toolkit consists of two test-beds for technical entity recognition and relation extraction engines, which are capable of identifying technical entities and predicting semantic relation types between the entities. With using the introduced toolkits, users and developers can efficiently perform the execution monitoring and error analysis of the technical text analysis engines.

A Designing Method of Network Quality Assurance Test Bed Design under Next-generation Network Environment (NGN(Next Generation Network)의 네트워크 품질 보증을 위한 테스트베드 모델 설계)

  • Chung, Ji Moon
    • Journal of Digital Contents Society
    • /
    • v.13 no.4
    • /
    • pp.625-629
    • /
    • 2012
  • This paper is presented to prepare NGN quality assurance management process under the quality system test methodology. The process should be drawn for NGN quality measurement framework of multimedia traffic. NGN test bed management process model are QoS measurement metrics, measurement interval meter above, and measuring tools, measuring equipment, measurement methods and measurement results from a series of processes for the analysis and methodology. This model, NGN quality assurance activities should be utilized in the future. Quality target level only when themselves constantly measured and managed, does not guarantee the communication quality of service. It is sensitive to the importance of NGN network technology paradigm for research on quality management in the NGN.

A Study of a Composite Sensor and Control Network and Its Test-bed for the Intelligent and Digital Home (지능형 디지탈홈을 위한 콤퍼짓 센서제어네트워크 및 테스트베드의 연구)

  • Lee, Kyou-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1687-1693
    • /
    • 2007
  • Advances in technologies of networking, chip integration, and embedded system have enabled sensor networks applicable to a wide range of areas. Sharing some common characteristics, sensor networks are thus diversified in features depending on their applications. An intelligent and digital home can be one area to establish a particular feature of sensor network. This paper proposes a composite sensor and control network, and discusses its applying to the next generation intelligent and digital home. Development results of the network and a test-bed as a virtual test environment are also presented. The proposed network can not only be efficiently applying to achieve new home intelligences but also provide a sound solution to maintenance and operations of home network or devices.

Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter (지능형 보호기기 적용 태양광 인버터 성능시험)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

A Reconfigurable Integration Test and Simulation Bed for Engagement Control Using Virtualization (가상화 기반의 재구성 용이한 교전통제 통합시험시뮬레이션 베드)

  • Kilseok Cho;Ohkyun Jeong;Moonhyung Yoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.91-101
    • /
    • 2023
  • Modeling and Simulation(M&S) technology has been widely used to solve constraints such as time, space, safety, and cost when we implement the same development and test environments as real warfare environments to develop, test, and evaluate weapon systems for the last several decades. The integration and test environments employed for development and test & evaluation are required to provide Live Virtual Construction(LVC) simulation environments for carrying out requirement analysis, design, integration, test and verification. Additionally, they are needed to provide computing environments which are possible to reconfigure computing resources and software components easily according to test configuration changes, and to run legacy software components independently on specific hardware and software environments. In this paper, an Integration Test and Simulation for Engagement Control(ITSEC) bed using a bare-metal virtualization mechanism is proposed to meet the above test and simulation requirements, and it is applied and implemented for an air missile defense system. The engagement simulation experiment results conducted on air and missile defense environments demonstrate that the proposed bed is a sufficiently cost-effective and feasible solution to reconfigure and expand application software and computing resources in accordance with various integration and test environments.

The Effect of a Bed-Backrest Elevation System Combined With Hip and Knee Flexion on Lower Extremity Body-Pressure Reduction

  • Kim, Min-Hee;Yoo, Won-Gyu;Yi, Chung-Hwi;Kim, Han-Sung;Kim, Su-Jin
    • Physical Therapy Korea
    • /
    • v.15 no.4
    • /
    • pp.59-63
    • /
    • 2008
  • Pressure sores are painful and needless complications of critical illness. and manifest as a localized area of ischemic necrosis of tissue caused by pressure. This study analyzed the bed-backrest elevation system combined with hip and knee flexion for lower extremity lower pressure reduction. Eight healthy adults aged 21 to 26 years were recruited. The Body Pressure Measurement Mat of the TekScan system was used to measure the location and magnitude of the peak pressures on the body bed interface. The SPSS statistical package was used to analyze the significance of differences between the general bed-backrest elevation system and the bed-backrest elevation system combined with hip and knee flexion using the paired t-test. The result showed that the body-pressure of the lower extremity was more significantly reduced for the bed-backrest elevation system combined with hip and knee flexion ($26.6{\pm}4.3$ mmHg) than a general bed-backrest elevation system ($37.3{\pm}5.2$ mmHg) (p<.05).

  • PDF

ENHANCEMENT OF DRYOUT HEAT FLUX IN A DEBRIS BED BY FORCED COOLANT FLOW FROM BELOW

  • Bang, Kwang-Hyun;Kim, Jong-Myung
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.297-304
    • /
    • 2010
  • In the design of advanced light water reactors (ALWRs) and in the safety assessment of currently operating nuclear power plants, it is necessary to evaluate the possibility of experiencing a degraded core accident and to develop innovative safety technologies in order to assure long-term debris cooling. The objective of this experimental study is to investigate the enhancement factors of dryout heat flux in debris beds by coolant injection from below. The experimental facility consists mainly of an induction heater, a double-wall quartz-tube test section containing a steel-particle bed and coolant injection and recovery condensing loop. A fairly uniform heating of the particle bed was achieved in the radial direction and the axial variation was within 20%. This paper reports the experimental data for 3.2 mm and 4.8 mm particle beds with a 300 mm bed height. The dryout heat density data were obtained for both the top-flooding and the forced coolant injection from below with an injection mass flux of up to $1.5\;kg/m^2s$. The dryout heat density increased as the rate of coolant injection increased. At a coolant injection mass flux of $1.0\;kg/m^2s$, the dryout heat density was ${\sim}6.5\;MW/m^3$ for the 4.8 mm particle bed and ${\sim}5.6\;MW/m^3$ for the 3.2 mm particle bed. The enhancement factors of the dryout heat density were 1.6-1.8.

A Study on Tensile Strength According to Various Output Conditions of PLA+ Materials Using 3D Printing (3D 프린팅을 이용한 PLA+ 소재의 다양한 출력 조건에 따른 인장강도에 대한 연구)

  • Na, D.H.;Kim, S.G.
    • Transactions of Materials Processing
    • /
    • v.31 no.2
    • /
    • pp.89-95
    • /
    • 2022
  • 3D printing products manufactured by material extrusion are used in many industrial fields recently. However, these products are difficult to use in the field due to their low tensile strengths. In order to solve this problem, research on improving the tensile strength of the output using a 3D printer has been continuously conducted. In this study, we performed a tensile test using Universal Testing Machine according to infill pattern, nozzle temperature, bed temperature, and printing speed conditions. Results revealed that tensile specimen of concentric shape had the highest tensile strength in infill pattern condition and that the tensile strength increased linearly with increasing nozzle and bed temperatures. However, the tensile strength decreased with increasing printing speed. Consequently, we confirmed that tensile strength could be increased and decreased depending on output conditions of 3D printing.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed (슬러지 순산소 유동층 연소특성)

  • Jang, Ha-Na;Sung, Jin-Ho;Choi, Hang Seok;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.846-853
    • /
    • 2017
  • Cold bed and $30kW_{th}$ pilot bed tests using circulating fluidized bed (CFB) were conducted to apply oxy-fuel technology for waste sludge combustion as a carbon capture and storage technology. In cold bed test, the minimum fluidization velocity ($u_{mf}$) and superficial velocity for fast fluidization was determined as 0.120 m/s and 2.5 m/s, respectively. In the pilot test, air and oxy-fuel combustion experiments for waste sludge were conducted using CFB unit. The flue-gas temperature in 21~25% oxy-fuel combustion was higher than that of air and up to 30% oxy-fuel combustion. In addition, the concentration of carbon dioxide was more than 80% with the oxygen injection range from 21% to 25% in oxy-fuel CFB waste sludge combustion.