• 제목/요약/키워드: Test-retest Method

검색결과 88건 처리시간 0.024초

레이저 미세피치 홀 가공의 생산효율성 향상을 위한 영상처리 측정 기법 적용 (Application of Image Processing Technique to Improve Production Efficiency of Fine Pitch Hole Based on Laser)

  • 표창률
    • 소성∙가공
    • /
    • 제19권5호
    • /
    • pp.320-324
    • /
    • 2010
  • Multi-Layer Ceramic Circuit(MLCC) in the face of thousands of fine pitch multi hole is processed. However, the fine pitch multi hole has a size of only a few micrometers. Therefore, in order to curtail the measurement time and reduce error, the image processing measurement method is required. So, we proposed an image processing measurement algorithm which is required to accurately measure the fine pitch multi hole. The proposed algorithm gets image of the fine pitch multi hole, extracts object from the image by morphological process, and extracts the parameters of its position and feature by edge detecting process. In addition, we have used the sub-pixel algorithm to improve accuracy. As a result, the proposed algorithm shows 97% test-retest measurement reliability within 2 ${\mu}m$. We found that the algorithm was wellsuited for measuring the fine pitch multi hole.

Development and Validation of a Multidimensional Measure of Positive Body Image

  • Lee, Minsun;Lee, Hyun-Hwa
    • 한국의류학회지
    • /
    • 제46권4호
    • /
    • pp.704-722
    • /
    • 2022
  • Current studies validate the Body Positive Scale (BP Scale) as a self-assessment instrument that captures four dimensions of the positive body image construct. We developed and evaluated a 17-item BP Scale using two focus group interviews and four independent samples (n = 1,379) of Korean women who completed online survey questionnaires. We generated an initial pool of items via literature review, content validation with experts, and focus group interviews, subsequently refining the items through exploratory analysis (Study 1). We confirmed the BP Scale's underlying dimensions with young Korean female samples (Study 2, Study 4) and with a community sample (Study 3). We also examined the construct validity, internal consistency, and test-retest reliability over a six-week interval. Overall, the results supported that the four-factor BP Scale demonstrates adequate validity and reliability in measuring positive body image among Korean women. The BP Scale provides a method for researchers and practitioners to understand and assess individuals' positive body image in a multifaceted manner.

하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토 (Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool)

  • 임지영;임현승;박대성;이재헌;이나경
    • 재활복지공학회논문지
    • /
    • 제10권1호
    • /
    • pp.37-45
    • /
    • 2016
  • 이 연구의 목적은 래스터입체사진술이 적용된 ABW-mapper를 사용하여 얻은 관상면 상에서의 하지 정렬 측정에 대하여 측정자 내, 측정자 간, 측정-재측정 간 각각의 신뢰도와 타당도를 조사하고 평가하는 것이다. 열여덟 명의 대상자가 이 연구에 참여하였다. 일주일간격으로 두 번의 세션에 걸쳐서 두 사람의 측정자가 각각 ABW-mapper를 사용하여 기립자세에서의 S각(입체사진 각-래스터입체사진 촬영을 통해 측정한 관상면상의 하지 정렬 측정 각)을 측정하였고, 첫 번째 세션에서는 짧은 시간 간격으로 한 측정자가 같은 대상자에 대하여 두 번씩 측정하였다. Q각은 디지털카메라로 기립자세를 촬영한 사진에서 고니어미터로 측정하였다. HKA각은 컴퓨터 기반 디지털 방사선 영상사진 위에서 측정 소프트웨어를 사용하여 측정하였다. 급내상관계수(ICC)를 통해 신뢰도를 분석하였고, 피어슨 상관계수를 사용하여 타당도를 검사하였다. 그 결과, S각 측정은 매우 높은 측정자 내 (ICC=0.956~0.974), 측정자 간 (ICC=0.962) 검사-재검사 간 (ICC=0.945) 신뢰도를 나타냈으며, S각과 Q각, S각과 HKA각 사이에는 강한 음의 상관관계(각각 r=-0.739, -0.702)를 나타냈다. 따라서, ABW-mapper에 의한 래스터입체사진법을 통한 S각 측정은 관상면에서의 하지정렬의 측정에 대하여 Q각이나 HKA각 측정에 관련하여 예비적 또는 보완적 도구로 사용될 수 있을 것이라 생각된다.

델파이 기법에 의한 한국 성인의 식습관 조사용 설문지 개발 (Development of a Questionnaire for Dietary Habit Survey of Korean Adults)

  • 조진숙;김기남
    • 대한지역사회영양학회지
    • /
    • 제19권3호
    • /
    • pp.258-273
    • /
    • 2014
  • Objectives: The purposes of the study were to develop a questionnaire for dietary habit survey for Korean adults, and unify the terms related to dietary habits. Methods: The Delphi method by 43 professionals on dietary habit research was applied to unify the terms. Results: With regard to results on terms related to dietary habit, the respondents recorded the highest percentage (90.7%) of selecting the term "dietary habits" and also the highest percentage (76.7%) of choosing "dietary habits" for English. The biggest percentage of the respondents chose "individual dietary behaviors repeatedly formed and habitualized under the social, cultural, and psychological influence in the group" as the concept of dietary habits. The Delphi survey for the development of a questionnaire resulted in the first questionnaire of 31 items, the second one of 27 items, and the third one of 25 items. The validity of questionnaire items was tested with content validity ratios (CVR). The items whose CVR value was 0.29 or lower were eliminated or revised, because the minimum CVR value needed to test validity was 0.29. To test the reliability of questionnaire items, test-retest method was performed in 163 adults. According to the Kappa coefficient in the range of 0.314-0.716, all of the 25 items were in the reliability scope. A survey was taken with 702 adults to finally revise and supplement the third questionnaire whose validity and reliability were tested. Conclusions: Through those processes, a questionnaire for adults' dietary habit survey was finally completed. The significance of the study lies in the development of the first questionnaire on dietary habits equipped with both validity and reliability in South Korea.

요통 환자를 대상으로 후중둔근 도수근력검사의 일치도 및 휴대용 근력계 측정 방법의 신뢰도 검사 (Agreement of Manual Muscle Testing and Test-Retest Reliability of Hand Held Dynamometer for the Posterior Gluteus Medius Muscle for Patients With Low Back Pain)

  • 박규남;김현숙;최흥식;이원휘;하성민;김수정
    • 한국전문물리치료학회지
    • /
    • 제18권3호
    • /
    • pp.67-75
    • /
    • 2011
  • The purpose of this study was to assess the agreement of manual muscle testing (MMT) and test-retest reliability of a hand held dynamometer for the posterior gluteus medius muscle, with and without lumbar stabilization, using a pressure biofeedback unit for patients with low back pain. The pressure biofeedback unit was used to minimize the substitute motion of the lumbopelvic region during hip abduction in patients lying on their side. Fifteen patients with low back pain participated in this study. A tester determined the MMT grades of the posterior gluteus medius with and without the pressure biofeedback unit. Active hip abduction range of motion with an inclinometer and the strength of their posterior gluteus medius using a hand held dynamometer were measured with and without the pressure biofeedback unit in the MMT position. The agreement of the grade of muscle strength in the MMT, and intra-rater reliability of both the active hip abduction range of motion and the strength of posterior gluteus medius were analyzed using the weighted kappa and intraclass correlation coefficient (ICC), respectively. The agreement of MMT with the pressure biofeedback unit (weighted kappa=.92) was higher than the MMT (weighted kappa=.34)(p<.05). The inclinometer with pressure biofeedback unit measurement of the active hip abduction range of motion had an excellent intra-rater reliability (ICC=.90). Also, the hand held dynamometer with pressure biofeedback unit measure of strength of the posterior gluteus medius had a good intra-rater reliability (ICC=.85). Therefore, the test for muscle strength with pressure biofeedback unit will be a reliable method for the determination of the MMT grades or amount of posterior gluteus medius muscle strength and the measurement of the range of motion for hip abduction in patients with low back pain.

경락노선상 피부전기 측정기 (EAV, MIR-1) 의 신뢰도 연구 (Reliability of Two Electrodermal Meridian Measurement Systems: EAV and Newly Developed MIR-1)

  • 인창식;허익범;이유정;사공석진;고형균;박영배;이우철
    • 대한한의진단학회지
    • /
    • 제9권1호
    • /
    • pp.125-130
    • /
    • 2005
  • Background and purpose: We evaluated the reliability of two electrodermal measurement devices on meridian skin areas; Electro Acupuncture according to Dr. Voll (EAV) method and newly developed MIR-1. Methods: Eighteen volunteers were tested repeatedly on the same condition with each device. To explore the intra-rater, inter-rater, and test-retest reliabilities, one rater tested each subject twice in succession, then the other rater tested the subject in a row. Finally, retests on the subjects with each device were performed 1 week later. The reliability was determined by Pearson correlation and intraclass correlation statistics. Results: EAV method showed poor reliability, while MIR-1 showed good reliability. Conclusion: It is suggested that further research on the reliability and useful device in both fields of clinical practice and biomedical research.

  • PDF

국내 아동 및 청소년 난독증 진단을 위한 종합학습능력평가도구-읽기의 표준화 연구 (Standardization of the Comprehensive Learning Test-Reading for the Diagnosis of Dyslexia in Korean Children and Adolescents)

  • 유한익;정재석;이은경;강성희;박은희;최인욱
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제27권2호
    • /
    • pp.109-118
    • /
    • 2016
  • Objectives: The aim of this study was to develop the computerized Comprehensive Learning Test-Reading (CLT-R) to evaluate the cognitive processes and achievements related to their basic reading ability and identify dyslexia in children and adolescents in South Korea. We also obtained the normative data and evaluated the reliability and validity of the test. Methods: We developed the CLT-R, including the word attack/nonword decoding, paragraph reading, sound blending, nonword repetition, rapid automatized naming, letter-sound matching, visual attention, orthography awareness, and digit span tests, for the purpose of diagnosing dyslexia. We investigated the reliability and validity of the tests and gathered the normative data from 399 subjects (male 48.9%), aged 5-14 years, from the last grade in kindergarten to middle school, dwelling in Seoul and Gyeonggi Province, South Korea. Results: No statistical differences were observed between the means of the tests and retests of the CAT. The mean of the correlation coefficient of the test-retest scores was 0.85. According to the construct validity test calculated by principal constant analysis using the oblique rotation method, 4 factors explained 70.0% of the cumulative variances. In addition, the normative data were obtained for all of the CLT-R subtests. Conclusion: The computerized CLT-R can be used as a reliable and valid tool to evaluate the reading achievement and reading related cognitive process in Korean children and adolescents in schools, clinics, and research institutes.

Psychometric Validation of the Bahasa Malaysia Version of the EORTC QLQ-CR29

  • Magaji, Bello Arkilla;Moy, Foong Ming;Roslani, April Camilla;Law, Chee Wei;Raduan, Farhana;Sagap, Ismail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8101-8105
    • /
    • 2016
  • Background: This study examined the psychometric properties of the Bahasa Malaysia (BM) version of the European Organization for Research and Treatment of Cancer (EORTC) Colorectal Cancer-specific Quality Of Life Questionnaire (QLQ-CR29). Materials and Methods: We studied 93 patients recruited from University Malaya and Universiti Kebangsaan Medical Centers, Kuala Lumpur, Malaysia using a self-administered method. Tools included QLQ-C30, QLQ-CR29 and Karnofsky Performance Scales (KPS). Statistical analyses included Cronbach's alpha, test-retest correlations, multi-traits scaling and known-groups comparisons. A p vaue ${\leq}0.05$ was considered significant. Results: The internal consistency coefficients for body image, urinary frequency, blood and mucus and stool frequency scales were acceptable (Cronbach's alpha ${\alpha}{\geq}0.65$). However, the coefficients were low for the blood and mucus and stool frequency scales in patients with a stoma bag (${\alpha}=0.46$). Test-retest correlation coefficients were moderate to high (range: r = 0.51 to 1.00) for most of the scales except anxiety, urinary frequency, buttock pain, hair loss, stoma care related problems, and dyspareunia (r ${\leq}0.49$). Convergent and discriminant validities were achieved in all scales. Patients with a stoma reported significantly higher symptoms of blood and mucus in the stool, flatulence, faecal incontinence, sore skin, and embarrassment due to the frequent need to change the stoma bag (p < 0.05) compared to patients without stoma. None of the scales distinguished between patients based on the KPS scores. There were no overlaps between scales in the QLQ-C30 and QLQ-CR29 (r < 0.40). Conclusions: the BM version of the QLQ-CR29 indicated acceptable psychometric properties in most of the scales similar to original validation study. This questionnaire could be used to complement the QLQ-C30 in assessing HRQOL among BM speaking population with colorectal cancer.

뇌성마비 환아 중증도별 시각화척도, 시간교환법, EQ-5D-Y Proxy를 이용한 삶의 질 측정 (Measuring Quality of Life in Cerebral Palsy Children According to the Severity Using the Visual Analogue Scale, Time Trade-Off, and EQ-5D-Y Proxy)

  • 이고은;김남권;윤영주;왕혜민;김정훈;이동효
    • 동의신경정신과학회지
    • /
    • 제28권2호
    • /
    • pp.49-59
    • /
    • 2017
  • Objectives: To measure the quality of life in patients according to virtual cerebral palsy severity by using the Korean version of EQ-5D-Y proxy, Visual Analogue Scale (VAS), and Time Trade-Off method (TTO). Methods: The study was conducted in parents of children and adolescents aged 4 to 15 years in Seoul. We analyzed the difference in the utility value according to five levels of cerebral palsy severity in the Gross Motor Function Classification System (GMFCS) and test-retest reliability. Results: 1. There were significant differences in VAS, TTO, and EQ-5D-Y proxy according to the cerebral palsy severity (p<.001). 2. VAS was significantly different according to the respondent's visit to the medical institution, the presence of disease in the respondent, a visit to the child's medical institution, the age of the child, and the sex of the child. The value of TTO was significantly different according to the respondent's visit to the medical institution, respondent's sex, and the age of the child. Also, EQ-5D-Y proxy was significantly different according to the age of the child. 3. Intraclass correlation coefficient values were more than 0.6 for both VAS and TTO at all stages. But for the EQ-5D-Y proxy, the value was less than 0.6 at all stages. Conclusions: The quality of life assessment using EQ-5D-Y proxy showed significant differences in the severity of cerebral palsy. However, large-scale studies using EQ-5D-Y proxy are needed because of low test-retest reliability.

Validity and reliability of the Korean version of the Quality of Recovery-40 questionnaire

  • Lee, Jun Ho;Kim, Deokkyu;Seo, Donghak;Son, Ji-seon;Kim, Dong-Chan
    • Korean Journal of Anesthesiology
    • /
    • 제71권6호
    • /
    • pp.467-475
    • /
    • 2018
  • Background: The Quality of Recovery-40 (QoR-40) is a widely-used, self-rated, and self-completed questionnaire for postoperative patients. The questionnaire is intended to elicit information from each patient regarding the quality of recovery during the postoperative period. It is noteworthy, however, that an official Korean version of the QoR-40 (QoR-40K) has not been established. The purpose of this study was to develop the QoR-40K by translation and cultural adaptation process and to evaluate the validity and reliability of the QoR-40K. Methods: After pre-authorization from the original author of the QoR-40, the translation procedure was established and carried out based upon Beaton's recommendation to create a QoR-40K model comparable to the original English QoR-40. Two hundred surgical patients were enrolled, and each completed the questionnaire during the preoperative period, on the third day, and 1 month after surgery. The QoR-40K was compared with the visual analogue scale (VAS) and another health-related questionnaire, the Short-form Health Survery-36 (SF-36). The method of validation for QoR-40K included test-retest reliability, internal consistency, and level of responsiveness. Results: Spearman's correlation coefficient for test-retest reliability was 0.895 (P < 0.001), and Cronbach's alpha of the global QoR-40K on the third day after surgery was 0.956. A positive correlation was obtained between the QoR-40K and the mental component summary of SF-36 (${\rho}=0.474$, P < 0.001), and a negative correlation was observed between QoR-40K and VAS (${\rho}=-0.341$, P < 0.001). The standardized responsive mean of the total QoR-40K was 0.71. Conclusions: The QoR-40K was found to be as acceptable and reliable as the original English QoR-40 for Korean patients after surgery, despite the apparent differences in the respective patients' cultural backgrounds.