• Title/Summary/Keyword: Test-area method

Search Result 2,527, Processing Time 0.034 seconds

Computer-Aided Diagnosis of Splenic Enlargement Using Wave Pattern of Spleen in Abdominal CT Images (복부 CT 영상에서 비장의 웨이브 형태를 이용한 비장 비대의 자동 진단)

  • Seong Won;Park Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.12B no.5 s.101
    • /
    • pp.553-560
    • /
    • 2005
  • Generally, it is known that the spleen accompanied by liver cirrhosis is hypertrophied or enlarged. We examined the wave pattern of the spleen by using abdominal CT images of a patient with liver cirrhosis, and found that they are different from those of a person with a normal liver In the abdominal CT image of the patient with liver cirrhosis, there is a deep wave part on the left side of the spleen. In the case of the normal liver, there are waves on the left side, but they aren't deep. Therefore, the total area of waving parts of the spleen with liver cirrhosis is found to be greater than that of the spleen with the normal liver. Moreover, when examining circularity by abstracting the waves of the spleen from the image iO liver cirrhosis, we found they are more circular than those of the spleen accompanied by a normal liver. This paper suggests an automatic method to diagnose splenic enlargement by using the wave pattern of the spleen in abdominal CT images on the basis of the two principles. It tells us that we can judge if the abdomen has a focal splenic enlargement automatically, without the manual test of the size of spleen, only with the shape of spleen.

A Study on the Alliance Partner Selection Criteria and Performance in Korean Venture Companies (벤처기업의 기술제휴 파트너 선정기준 및 성과에 관한 연구)

  • Kim, Hwan-Jin
    • Journal of Korea Technology Innovation Society
    • /
    • v.17 no.3
    • /
    • pp.540-562
    • /
    • 2014
  • Although the impact of technological partner selection on the success of technological alliance is critical, little attention has been paid to the area of technological alliance partner selection criteria and the relationship between partner selection criteria and success factors of alliance. This study bridges this gap by understanding previous studies of general alliance partner selection criteria such as marketing, international, logistics and production alliances. I drew technological alliance partner selection criteria using AHP method with 12 experts who are currently in charge of technological alliance activities at Korean Venture Companies. This study found 4 criteria such as 'task-related', 'partner-related', 'learning-related', 'risk-related' criteria with 14 items and the relative importance of technological alliance partner selection showed as follows: 'risk-related', 'learning-related', 'partner-related', 'task-related' criteria. In order to test the relationship between technological partner selection criteria and performance, I used 215 survey data of Korean Venture Companies. The results showed that 'partner-related' and 'task-related' criteria had strong positive impacts on the success of technological alliance. Further, I put 4 moderating variables into the study model in order to see their moderating effects. However, no moderating variable showed significant effects. In conclusion section, I discussed the findings and implications of this study and directions for future studies.

Pressure Distribution over Tube Surfaces of Tube Bundle Subjected to Two-Phase Cross-Flow (이상 유동에 놓인 관군의 표면에 작용하는 압력 분포)

  • Sim, Woo Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • Two-phase vapor-liquid flows exist in many shell and tube heat exchangers such as condensers, evaporators, and nuclear steam generators. To understand the fluid dynamic forces acting on a structure subjected to a two-phase flow, it is essential to obtain detailed information about the characteristics of a two-phase flow. The characteristics of a two-phase flow and the flow parameters were introduced, and then, an experiment was performed to evaluate the pressure loss in the tube bundles and the fluid-dynamic force acting on the cylinder owing to the pressure distribution. A two-phase flow was pre-mixed at the entrance of the test section, and the experiments were undertaken using a normal triangular array of cylinders subjected to a two-phase cross-flow. The pressure loss along the flow direction in the tube bundles was measured to calculate the two-phase friction multiplier, and the multiplier was compared with the analytical value. Furthermore, the circular distributions of the pressure on the cylinders were measured. Based on the distribution and the fundamental theory of two-phase flow, the effects of the void fraction and mass flux per unit area on the pressure coefficient and the drag coefficient were evaluated. The drag coefficient was calculated by integrating the measured pressure on the tube by a numerical method. It was found that for low mass fluxes, the measured two-phase friction multipliers agree well with the analytical results, and good agreement for the effect of the void fraction on the drag coefficients, as calculated by the measured pressure distributions, is shown qualitatively, as compared to the existing experimental results.

Bioequivalence of Prepulsid Tablet to Cisaple Tablet (Cisapride 5 mg) (프레팔시드 정(시사프리드 5 mg)에 대한 시사플 정의 생물학적 동등성)

  • Kwak, Son-Hyuk;Nam, Jin-Kyung;Jiang, Ge;Han, Jung-Hee;Woo, Jong-Soo;Rhee, Gye-Ju;Park, Jong-Woo;Koo, Sun-Hoe;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.1
    • /
    • pp.55-59
    • /
    • 2000
  • Bioequivalence of two cisapride tablets, test drug ($Cisple^{\circledR}$ tablet: Hanmi Pharm Co., Ltd.) and reference drug ($Prepulsid^{\circledR}$ tablet: Janssen Pharm. Co., Ltd.), was evaluated according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty two healthy male volunteers were divided randomly into two groups and administered the drug orally at the dose of 10 mg as cisapride in a $2{\times}2$ crossover study. There was a week washout period between administrations. Blood samples were taken at predetermined time intervals for 36 hr and the plasma concentration of cisapride was determined by a HPLC method. $AUC_{0-36hr}$ (area under the plasma concentration-time curve from time zero to 36 hr), $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were estimated from the plasma drug concentration-time data. Analysis of variance (ANOVA) revealed no difference in $AUC_{0-36hr},\;C_{max}\;and\;T_{max}$ between two products. The apparent differences of these parameters between two products were less than 20% (i.e., 5.38, 6.17 and 0.00% for $AUC_{0-36hr},\;C_{max}\;and\;T_{max},$ respectively). The powers $(1-\beta)$ for $AUC_{0-36hr},\;C_{max}\;and\;T_{max}$ were over 0.9. Minimal detectable differences $(\Delta)$ at ${\alpha}=0.05,\;1-{\beta}=0.8$ were less than 20% (i.e. 17.67, 14.84 and 19.72% for $AUC_{0-36hr},\;C_{max}\;and\;T_{max},$ respectively). The 90% confidence intervals $(\delta)$ for these parameters were also within ${\pm}20%$ $(i.e.\;-4.97\;{\le}{\delta}{\le}\;15.73,\;-2.53{\le}{\delta}{\le}\;14.86\;and\;-11.55{\le}{\delta}{\le}\;11.55$ for $AUC_{0-36hr},\;C_{max}\;and\;T_{max},$ respectively). These results satisfied the criteria of KFDA guidelines for bioequivalence, indicating the two tablets of cisapride were bioequivalent.

  • PDF

Evaluation of Flexural Behavior of Hollow Prestressed Concrete Pile for Continuous Pile Wall (주열식 벽체용 중공 프리스트레스트 콘크리트 파일의 휨거동 평가)

  • Lee, Young-Geun;Jang, Min-Jun;Yoon, Soon-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • In the construction site, various earth retaining systems are developed and applied to maintain stability of excavated area and structures. Among the methods, the underground continuous wall and the column-type diaphragm wall methods are especially used in construction site nearby buildings or roads. However, these methods have some disadvantages such as the difficulty of quality control and long curing time because these methods need to cast fresh concrete at the construction site. In addition, these methods are usually applied to the site for the temporary purpose. In this paper, we suggest precast hollow prestressed concrete pile for continuous pile wall system. To investigate the structural behavior of suggested pile, which is the main member of the suggested system, tests pertaining to the structural behavior and prestressing force applied in the pile are conducted. From the test results, it was found that the prestressing force measured is sufficient compared with the value obtained by the design equation and the cracking moment measured is 34% higher than the design value. In addition to the above, this precast hollow prestressed concrete pile has an additional safety margin that the maximum moment is 59.2% higher than the cracking moment which is one of the serviceability limits for the design of the system.

Occurrence and antibiotic susceptibility of fish bacteria isolated from Oreochromis niloticus (Nile tilapia) and Clarias gariepinus (African catfish) in Uganda

  • Wamala, S.P.;Mugimba, K.K.;Mutoloki, S.;Evensen, O.;Mdegela, R.;Byarugaba, D.K.;Sorum, H.
    • Fisheries and Aquatic Sciences
    • /
    • v.21 no.2
    • /
    • pp.6.1-6.10
    • /
    • 2018
  • The intention of this study was to identify the bacterial pathogens infecting Oreochromis niloticus (Nile tilapia) and Clarias gariepinus (African catfish), and to establish the antibiotic susceptibility of fish bacteria in Uganda. A total of 288 fish samples from 40 fish farms (ponds, cages, and tanks) and 8 wild water sites were aseptically collected and bacteria isolated from the head kidney, liver, brain and spleen. The isolates were identified by their morphological characteristics, conventional biochemical tests and Analytical Profile Index test kits. Antibiotic susceptibility of selected bacteria was determined by the Kirby-Bauer disc diffusion method. The following well-known fish pathogens were identified at a farm prevalence of; Aeromonas hydrophila (43.8%), Aeromonas sobria (20.8%), Edwardsiella tarda (8.3%), Flavobacterium spp. (4.2%) and Streptococcus spp. (6.3%). Other bacteria with varying significance as fish pathogens were also identified including Plesiomonas shigelloides (25.0%), Chryseobacterium indoligenes (12.5%), Pseudomonas fluorescens (10.4%), Pseudomonas aeruginosa (4.2%), Pseudomonas stutzeri (2.1%), Vibrio cholerae (10.4%), Proteus spp. (6.3%), Citrobacter spp. (4.2%), Klebsiella spp. (4.2%) Serratia marcescens (4.2%), Burkholderia cepacia (2.1%), Comamonas testosteroni (8.3%) and Ralstonia picketti (2.1%). Aeromonas spp., Edwardsiella tarda and Streptococcus spp. were commonly isolated from diseased fish. Aeromonas spp. (n = 82) and Plesiomonas shigelloides (n = 73) were evaluated for antibiotic susceptibility. All isolates tested were susceptible to at-least ten (10) of the fourteen antibiotics evaluated. High levels of resistance were however expressed by all isolates to penicillin, oxacillin and ampicillin. This observed resistance is most probably intrinsic to those bacteria, suggesting minimal levels of acquired antibiotic resistance in fish bacteria from the study area. To our knowledge, this is the first study to establish the occurrence of several bacteria species infecting fish; and to determine antibiotic susceptibility of fish bacteria in Uganda. The current study provides baseline information for future reference and fish disease management in the country.

Computer-Aided Diagnosis of Liver Cirrhosis using Wave Pattern of Spleen in Abdominal CT Imaging (복부 CT영상에서 비장의 웨이브 패턴을 이용한 간경변의 자동 진단)

  • Seong Won;Cho June-Sik;Noh Seung-Moo;Park Jong-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.6
    • /
    • pp.532-541
    • /
    • 2005
  • We examined the wave pattern of the spleen by using abdominal CT images of a patient with liver cirrhosis, and found that they are different from those of a person with a normal liver. In the abdominal CT image of the patient with liver cirrhosis, there is a deep wave part on the left side of the spleen. In the case of the normal liver, there are waves on the left side, but they aren't deep. Therefore, the total area of waving parts of the spleen with liver cirrhosis is found to be greater than that of the spleen with the normal liver. Moreover, when examining circularity by abstracting the waves of the spleen from the image with liver cirrhosis, we found they are more circular than those of the spleen accompanied by a normal liver. This paper suggests an automatic method to diagnose liver cirrhosis by using the wave pattern of the spleen in abdominal CT images on the basis of the two principles. It tells us that we can judge if the liver has liver cirrhosis automatically, without the manual test of the ratio of caudate lobe to right lobe, only with the spleen.

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

The Determinants and Comparison of Health Behavior and Health Service by Private Medical Insurance on National Health-Nutrition Survey (국민건강영양조사 대상자들의 민간의료보험 가입 요인 및 가입여부에 따른 건강행태·의료이용 비교)

  • Lee, Yong-Chul;Im, Bock-Hee;Park, Young-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.190-204
    • /
    • 2010
  • This study firstly examined the socioeconomic and health factors associated with infiltration of private health insurance. Secondly, we compared health behavior, outpatient and inpatient use of private health insured with uninsured. The method of this study is that secondary analysis of the 2008 Korea National Health and Nutrition Survey was conducted for 7178 respondents aged 19 over. We use the logistic regression and t-test for data analysis. The first dependent variable was dichotomy which is divided to private health insured or uninsured and the second dependent variable was the presence and frequency of outpatient and inpatient use. The descriptive variables was gender, age, marital status, income, education, occupation, type of national health insurance, residential area, self confidence of health, prevalence rate of common disease, activity limitation, drinking and smoking status. The result of the major findings are as follows. First, 59 under aged person, married person, people in the higher brackets of income, national employee insured were more likely to infiltrate private health insurance. The poor self confidence of health, activity limitation, person with hypertension or allergic rhinitis and smoker were negatively related in infiltrating private health insurance. Second, private health insured did more preventive behavior such as self-paid health examination, cancer screening, regular exercise than uninsured. Third, private health insured was positively related with the presence of outpatient use and frequency of inpatient use

Bioequivalence Evaluation of Two Brands of Zolpidem Tartrate 10 mg Tablets(Zanilo and Stilnox) in Healthy Male Volunteers

  • Ryu, Ju-Hee;Lee, Heon-Woo;Lee, Hyun-Su;Kang, Il-Mo;Seo, Ji-Hyung;Kang, Jin-Yang;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.343-348
    • /
    • 2006
  • The purpose of the present study was to evaluate the bioequivalence of two zolpidem tartrate tablets, Stilnox tablet(Sanofi-aventis Korea, reference product) and Zanilo tablet(ChoDang Pharm Co., Ltd., Korea, test product), according to the guidelines of Korea Food and Drug Administration(KFDA). After adding an internal standard(cimetropium), 250 ${\mu}L$ plasma samples were extracted using 1.3 mL of ethyl acetate. Extracted compounds were analyzed by HPLC with triple-quadrupole mass spectrometry. This method for determination of zolpidem is proved accurate and reproducible with the limit of quantitation of 1 ng/mL in human plasma. Twenty-four healthy male Korean volunteers received each medicine at the zolpidem tartrate dose of 10 mg in a $2{\times}2$ crossover study. There was one-week washout period between the doses. Plasma concentrations of zolpidem were monitored for over a period of 8 hr after the administration. $AUC_{0-t}$(the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{0-t}$ and $C_{max}$. No significant sequence effect was found for all of the bio-availability parameters indicating that the crossover design was properly performed. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25(e.g., log 0.92-log 1.06 for $AUC_{0-t}$, log 0.96-log 1.13 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that Zanilo tablet is bioequivalent to Stilnox tablet.