• Title/Summary/Keyword: Test temperatures

Search Result 1,767, Processing Time 0.031 seconds

Local bond-slip behavior of medium and high strength fiber reinforced concrete after exposure to high temperatures

  • Tang, Chao-Wei
    • Structural Engineering and Mechanics
    • /
    • v.66 no.4
    • /
    • pp.477-485
    • /
    • 2018
  • This study aims to investigate the influence of individual and hybrid fiber on the local bond-slip behavior of medium and high strength concrete after exposure to different high temperatures. Tests were conducted on local pullout specimens (150 mm cubes) with a reinforcing bar embedded in the center section. The embedment lengths in the pullout specimens were three times the bar diameter. The parameters investigated include concrete type (control group: ordinary concrete; experimental group: fiber concrete), concrete strength, fiber type and targeted temperature. The test results showed that the ultimate bond stress in the local bond stress versus slip curve of the high strength fiber reinforced concrete was higher than that of the medium strength fiber reinforced concrete. In addition, the use of hybrid combinations of steel fiber and polypropylene fiber can enhance the residual bond strength ratio of high strength concrete.

Strength Properties of RC Slabs under Elevated Temperatures from Fire (화재시 온도증가로 인한 RC 슬래브의 강도 특성)

  • Im, Cho-Rong;Chung, Chul-Hun;Kim, Yu-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

Effect of the Mold Temperatures on the Microstructure and Mechanical Properties of Low Pressure Die-Cast Product (저압주조품의 미세조직과 기계적성질에 미치는 금형온도의 영향)

  • Lee, Jeong-Keun;Park, Chong-Sung;Kim, Myung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.18 no.3
    • /
    • pp.254-261
    • /
    • 1998
  • Microstructure and mechanical properties of the low pressure die-cast Al wheels were investigated by microscope, image analyzer, NDT (non-destructive test), and tensile test. The variation of SDAS (secondary dendrite arm spacing), porosity per unit area, quality grade, and tensile properties with the mold temperatures were examined. SDAS was gradually decreased with a decrease in temperature. However, the lowest value of porosity per unit area was observed at the mold temperature of $405^{\circ}C$ and the optimum mold temperature was found to be $405^{\circ}C$. Besides, from the observation of pore morphology, it was also found that the pore formation was mainly caused by shrinkage during solidification. The tensile strength, elongation, and impact toughness were markedly decreased, however the yield strength was nearly constant. The decrease of mechanical properties is attributed to the increase of porosity.

  • PDF

A Study on the Preference of Fluorescent Lamp and White LEDs by the Comparison of Color Temperature in a Office Space (사무공간에서 형광램프 조명기구와 백색 LED 조명기구의 색온도 비교를 통한 선호도에 관한 연구)

  • Jung, Yeon-Hong;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.3-6
    • /
    • 2008
  • The purpose of this study is to investigate the luminous environment of fluorescent lamp and LED lamp in a office space for various color temperature by subject response test. For this, three different color temperatures were tested for the same illuminance level. Based on such test results for various color temperatures of fluorescent lamp and white LEDs, this study is to analyze the preferences of color temperature and light source, and perceptional brightness of each light source and color temperature. Then, this study is to derive the guidelines for the performance of color temperature which are suitable on the purpose and the mood of a office space.

  • PDF

A Study on the Compensation of the Thermal Errors for Machine Tool (공작기계 열변위 보정에 관한 연구)

  • 이인재
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.673-678
    • /
    • 2000
  • This paper presents an indirect compensation of thermal errors during machining, in which thermal error is modeled as a linear regression of temperatures measured at 4 specified positions. In this regression model, weighting coefficients of the measured temperatures were estimated by using the least square method. The grinding test with compensation, after 4-hour warming-up operation before the test, showed that the maximum machining error of the work pieces was reduced to 12${\mu}{\textrm}{m}$ while it measured 28${\mu}{\textrm}{m}$ without compensation. Furthermore the standard deviation of machining errors was also reduced from 8${\mu}{\textrm}{m}$ to 2${\mu}{\textrm}{m}$.

  • PDF

Objective Evaluation of Learning Performance according to the Color Temperature of LED Illumination (LED 조명의 색 온도에 따른 학습 성과의 객관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.2
    • /
    • pp.25-33
    • /
    • 2011
  • This study performs the objective evaluation on simple comparison and calculation works by students under LED illumination conditions according to three types of color temperatures (7000K, 5000K, 3000K) in the classroom, Since the objective of this study is to develop an electric lighting conditions suitable for students in the classroom, the learning performance under three types of LED illumination conditions were analyzed. The 4 kinds of simple tests concerning with learning performance were developed and test results under natural light and LED illumination by 3 types of color temperatures were analyzed. There were differences by t-test in most cases among simple experiment results of different illumination conditions ($p{\leq}.05$). It was confirmed that illumination condition plays an important role when students simply compare words or perform arithmetic calculations. The experimental results of this study might be applied to designing better luminous environment.

  • PDF

Hot Deformation Behavior of Bearing Steels and Their Optimal Hot Forging Conditions (베어링강의 고온변형특성과 열간 단조조건에 관한 연구)

  • 문호근;이재성;윤선준;전만수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.159-162
    • /
    • 2002
  • In this paper the stress-strain curves of bearing steels at hot working conditions are obtained by compression test with a computer controlled servo-hydraulic Gleeble 3800 testing machine and elongations and reductions of area of the bearing steels are obtained by tensile test with a computer controlled servo-hydraulic Gleeble 1500 testing machine. These tests have been focused to obtain the flow stress data and optimal hot forging conditions under various conditions of strain rates and temperatures. The strain rate sensitivity exponent and reduction of area of the materials are evaluated. Experimental results are resented for various conditions of temperatures and strain rates.

  • PDF

Studies on the Aging of Rubber Vulcanizates(PART I) (고무 제품(製品)의 노화성(老化性)에 관(關)한 연구(硏究)(제1보(第1報)))

  • Huh, Dong-Sub;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.1 no.1
    • /
    • pp.56-62
    • /
    • 1966
  • The aging characteristics of vulcanized rubber products manufactured in Korean industries have been studied, especially in terms of relationship between aging temperature and time, and also the comparison of results between Geer's oven testing and tube testing was made. It was assessed from changes in tensile properties resulting from conditioning at elevated temperatures for specified period of time. Even though the recipe of each sample is different, the results, as would be expected, has shown that at lower aging temperature the change of tensile strength indicate moderately and at the elovated severely as shown in Figure 9. Consequently, in spite of that the results from conditioning at various temperatures for certain specified period of time must be equivalent to each other, it shows inignorable tolerance. The results of Geer's oven test and tube test have shown slightly different value. It seemed to be caused by the result of migration phenomena on aging in Geer's oven.

  • PDF

The Effects of Fuel Injection Skips on the Reduction of Harmful Exhaust Gases during an SI Engine Starting (가솔린 기관의 시동시 연료분사스킵이 유해배출가스 저감에 미치는 영향)

  • Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 2006
  • During the SI engine starting up, starting conditions directly contribute to the harmful emissions in spark ignition engines. The effects of catalyst temperatures and fuel injection skip methods on HC emissions were investigated. The test was conducted on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine. To understand the formation of HC emissions, HC concentration was measured in an exhaust port using a Fast Response Flame Ionization Detector(FRFID). The result showed that HC emissions, which were generated during initial stage of the starting, could be reduced by coolant temperature and fuel injection skips. And through the vehicle test of ECE15+EUDC, it is convinced that the optimized fuel injection skip method according to coolant temperatures have favourable effects on the reduction of harmful exhaust emissions including HC during the SI engine start.

  • PDF

Mechanical testing of the behavior of steel 1.7147 at different temperatures

  • Brnic, Josip;Turkalj, Goran;Canadija, Marko
    • Steel and Composite Structures
    • /
    • v.17 no.5
    • /
    • pp.549-560
    • /
    • 2014
  • The paper provides the test results and analysis on the behavior of steel 1.7147 at different temperatures. Mechanical uniaxial tests were used to determine mechanical properties, resistance to creep and Charpy impact tests to determine impact energy. Test results are presented in the form of engineering stress-strain diagrams, creep curves as well as numerical data related to impact energy. The results show that the tensile strength has the highest value at room temperature, and the same goes for the yield strength as well as for modulus of elasticity. After room temperature both of mentioned properties decrease with temperature increasing. Some of creep curves were modeled using rheological models and analytical equation. Based on Charpy impact energy an assessment of fracture toughness was made.