• Title/Summary/Keyword: Test targets

Search Result 401, Processing Time 0.027 seconds

IMAGING SIMULATIONS FOR THE KOREAN VLBI NETWORK(KVN) (한국우주전파관측망(KVN)의 영상모의실험)

  • Jung, Tae-Hyun;Rhee, Myung-Hyun;Roh, Duk-Gyoo;Kim, Hyun-Goo;Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • The Korean VLBI Network (KVN) will open a new field of research in astronomy, geodesy and earth science using the newest three Elm radio telescopes. This will expand our ability to look at the Universe in the millimeter regime. Imaging capability of radio interferometry is highly dependent upon the antenna configuration, source size, declination and the shape of target. In this paper, imaging simulations are carried out with the KVN system configuration. Five test images were used which were a point source, multi-point sources, a uniform sphere with two different sizes compared to the synthesis beam of the KVN and a Very Large Array (VLA) image of Cygnus A. The declination for the full time simulation was set as +60 degrees and the observation time range was -6 to +6 hours around transit. Simulations have been done at 22GHz, one of the KVN observation frequency. All these simulations and data reductions have been run with the Astronomical Image Processing System (AIPS) software package. As the KVN array has a resolution of about 6 mas (milli arcsecond) at 220Hz, in case of model source being approximately the beam size or smaller, the ratio of peak intensity over RMS shows about 10000:1 and 5000:1. The other case in which model source is larger than the beam size, this ratio shows very low range of about 115:1 and 34:1. This is due to the lack of short baselines and the small number of antenna. We compare the coordinates of the model images with those of the cleaned images. The result shows mostly perfect correspondence except in the case of the 12mas uniform sphere. Therefore, the main astronomical targets for the KVN will be the compact sources and the KVN will have an excellent performance in the astrometry for these sources.

The Relationship between Intracellular Protein Kinase C Concentration and Invasiveness in U-87 Malignant Glioma Cells (교모세포종 세포주 U-87에서 세포내 PKC 농도와 종양침습성과의 상관 관계)

  • Ji, Cheol;Cho, Kyung-Keun;Lee, Kyung Jin;Park, Sung Chan;Cho, Jung Ki;Kang, Joon Ki;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.263-271
    • /
    • 2001
  • Objective : Glioblastomas, the most common type of primary brain tumors, are highly invasive and cause massive tissue destruction at both the tumor invading edges and in areas that are not in direct contact with glioma cells. As a result, patients with high-grade gliomas are faced with a poor prognosis. Such grim statistics emphasize the need to better understand the mechanisms that underlie glioma invasion, as these may lead to the identification of novel targets in the therapy of high grade gliomas. Protein kinase C(PKC) is a family of serine/threonine kinases and an important signal transduction enzyme that conveys signals generated by ligand-receptor interaction at the cell surface to the nucleus. PKC appears to be critical in regulating many aspects of glioma biology. The purpose of this study was to assess accurately the role of PKC in the invasion regulation of human gliomas based on hypothesis that protein kinase C(PKC) is functional in the process of glial tumor cell invasion. Method : To test this hypothesis, U-87 malignant glioma cell line intracellular PKC levels were up and down regulated and their invasiveness was tested. Intracellular PKC level was characterized using PKC activity assays. Invasion assays including barrier migration and spheroid confrontation were used to study the relationship between PKC concentration and invasiveness. Result : The cell line which were treated by PKC inhibitor tamoxifen and hypericin exhibited decreased PKC activity and decreased invasive abilities dose dependently both in matrigel invasion assay and tumor spheroid fetal rat brain aggregates(FRBA) confrontation assay. However, the cell line that was treated by PKC activator 12-O-tetradecanylphorbol-13acetate(TPA) did not exhibit increases in either PKC activity or invasive ability. Conclusion : These studies suggest that PKC may be a useful molecular target for the chemotherapy of glioblastoma and other malignancies and that a therapeutic approach based on the ability of PKC inhibitors may be helpful in preventing invasion.

  • PDF

Four-Channel Differential CMOS Optical Transimpedance Amplifier Arrays for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다 시스템용 4-채널 차동 CMOS 광트랜스 임피던스 증폭기 어레이)

  • Kim, Sang Gyun;Jung, Seung Hwan;Kim, Seung Hoon;Ying, Xiao;Choi, Hanbyul;Hong, Chaerin;Lee, Kyungmin;Eo, Yun Seong;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.82-90
    • /
    • 2014
  • In this paper, a couple of 4-channel differential transimpedance amplifier arrays are realized in a standard 0.18um CMOS technology for the applications of linear LADAR(laser detection and ranging) systems. Each array targets 1.25-Gb/s operations, where the current-mode chip consists of current-mirror input stage, a single-to-differential amplifier, and an output buffer. The input stage exploits the local feedback current-mirror configuration for low input resistance and low noise characteristics. Measurements demonstrate that each channel achieves $69-dB{\Omega}$ transimpedance gain, 2.2-GHz bandwidth, 21.5-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -20.5-dBm), and the 4-channel total power dissipation of 147.6-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations. Meanwhile, the voltage-mode chip consists of inverter input stage for low noise characteristics, a single-to-differential amplifier, and an output buffer. Test chips reveal that each channel achieves $73-dB{\Omega}$ transimpedance gain, 1.1-GHz bandwidth, 13.2-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -22.8-dBm), and the 4-channel total power dissipation of 138.4-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations.

Investigation on Factors Influencing the Quality of Life of Arthritis Patients (관절염환자의 삶의 질에 영향을 미치는 요인탐색)

  • Oh, Hyun Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.3
    • /
    • pp.431-451
    • /
    • 2000
  • In this paper, I will examine the variables influencing the Quality of Life of arthritis patients and present basic materials which help arthritis patients have positive thinking in life and ultimately lead a satisfactory life. The subjects for this study are 231 inpatients and outpatients with arthritis living in J and K city in Chonbug Province. For the analysis of collected data I employed the SAS program. The variables for characteristics and the quality of life were analysed by descriptive statistics, T-test and ANOVA, and the relations among variables were analysed through Pearson Correlation; the Regression method was employed to predict the factors affecting quality of life. For the validity of reliance on measuring equipment Cronbach Alpha was used. The results of the study are as follows : (1) The mean score of quality of life of arthritis patients is 3.09(5 in the maximum). The general characteristics which affect the quality of life are age(F=5.13, p=0.0006), standard of education(F=6.49, p=0.0003), marriage status(F=7.77, p=0.0005), monthly pay(F=4.37, p=0.0020), medical benefits (F=4.85, p=0.0087), and supports(F=4.39, p=0.0050). For the disease-related characteristics, there is a significant difference in the 6 items: pain control method(F=5.92, p= 0.0002), physical therapy(F=3.25, p=0.013), whethere or not patients exercise(F=4.62, p=0.0000), regularity of exercise(F=4.79, p=0.0000), frequency of exercise(F=6.29, p=0.0001), and amount of exercise(F=4.62, p=0.0043). Depending on the type of arthritis, there is also a significant difference in the degree of pain felt. The patients with infectious arthritis suffer from pain the most, followed by those with gout, rheumatism and degenerative arthritis, in that order. Although statistics don't show any convincing evidence, those with gout perceive that they are in best health condition, followed by those with rheumatism, degenerative arthritis, and infectious arthritis, in that order(F=2.23, p=0.0669). (2) The quality of life of arthritis patients is correlated positively with perceived health status(r=0.56, p=0.0001), health promoting behavior(r=0.53, p=0.0001), family support (r=0.46, p=0.0001), amount of exercise (r=0.36, p=0.0001), ADL(r=0.36, p=0.0001), HLOC(r=0.32, p=0.0001), frequency of exercise(r=0.32, p=0.0001)in that order, while correlated negatively with the degree of pain felt(r=-0.32, p=0.0001), the number of pain regions(r=-0.19, p= 0.0041), and the duration of pain(r=-0.14, p=0.0279). (3) Regression analysis reveals that the most powerful predictor of the quality of life is perceived health status, which account for 31.11%. The other predictors of the quality of life, which account for 60.22%, are health promoting behavior(16.51%), family support(3.81%), ADL(2.52%), gender(1.86%), the number of family members(1.36%), level of pain(1.24%), duration of pain (1.08%), and level of education(0.67%). The results of the study show that perceived health status and health promoting behavior are the two most important variables. However, considering that the perceived health condition is difficult to control by nursing intervention, it is suggested that the level of expectation for patients, must be decided first, and the health promoting behavior and the family support influencing the quality of life must be taken into account as targets for nursing intervention. As a way of controlling the quality of life, I think that a more comprehensive approach comprising the above important variables along with demographic and general characteristics is needed. I also suggest that we must continue to explore the variables affecting the quality of life and include those variables in nursing intervention.

  • PDF

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

Analysis of rpoB Gene in Rifampin-Resistant M. Tuberculosis by Direct Sequencing and Line Probe Assay (염기서열결정과 Line Probe 분석법에 의한 Rifampin내성 결핵균의 rpoB 유전자 분석)

  • Lee, Min-Ki;Kim, Yun-Seong;Lee, Hyo-Jin;Cheon, Du-Su;Yun, Sang-Myung;Park, Sam-Seok;Kim, Cheol-Min;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.251-263
    • /
    • 1997
  • Background : The emergence of multidrug-resistant strains of Mycobacterium tuberculosis presents a significant challange to the treatment and control of tuberculosis, and there is an urgent need to understand the mechanisms by which strains acquire multidrug resistance. Recent advances in molecular methods for the detection of M. tuberculosis genetic targets have approached the sensitivity of culture. Furthermore the prospect of determining resistance in mycobacteria at the nucleic acid level particulary to first-line drugs like rifampin, isoniazid has provided a glimps of the next generation of sensitivity test for M. tuberculosis. Previous studies in RMP resistant M. tuberculosis have shown that mutation in $\beta$subunit of RNA polymerase is main mechanism of resistance. Method : In this study, rpoB gene for the $\beta$subunit of RNA polymerase from M. tuberculosis of 42 cultured samples (32 were RMP resistant and 10 were sensitive cases) were isolated and characterised the mutations. Direct sequencing data were compared with the results of INNO-LiPA Line Probe Assay (LiPA, Innogenetics, Belgium), commercial RMP resistance detecting kit using reverse hybridization method. Results : All of the RMP resistant samples were revealed the presence of mutation by LiPA. In 22 samples (68.8%) out of 32 RMP resistant cases, the mutation types were confirmed by the positive signal at one of 4 mutation bands in the strip. The most frequent type was R5 (S531L) which were 17 cases (77.3%). Results of direct sequencing were identified the exact characteristics of 8 mutations which were not confirmed by LiPA. S522W type point mutation and 9 base pair deletion at codon 513~515 were new identified mutations for the first time. Conclusion : Mutations in rpoB gene is the main mechanism of RMP resistance in M. tuberculosis and LiPA is a very useful diagnostic tool for the early diagnosis of RMP resistance in M. tuberculosis.

  • PDF

Accuracy Analysis of Target Recognition according to EOC Conditions (Target Occlusion and Depression Angle) using MSTAR Data (MSTAR 자료를 이용한 EOC 조건(표적 폐색 및 촬영부각)에 따른 표적인식 정확도 분석)

  • Kim, Sang-Wan;Han, Ahrim;Cho, Keunhoo;Kim, Donghan;Park, Sang-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.457-470
    • /
    • 2019
  • Automatic Target Recognition (ATR) using Synthetic Aperture Radar (SAR) has been attracted attention in the fields of surveillance, reconnaissance, and national security due to its advantage of all-weather and day-and-night imaging capabilities. However, there have been some difficulties in automatically identifying targets in real situation due to various observational and environmental conditions. In this paper, ATR problems in Extended Operating Conditions (EOC) were investigated. In particular, we considered partial occlusions of the target (10% to 50%) and differences in the depression angle between training ($17^{\circ}$) and test data ($30^{\circ}$ and $45^{\circ}$). To simulate various occlusion conditions, SARBake algorithm was applied to Moving and Stationary Target Acquisition and Recognition (MSTAR) images. The ATR accuracies were evaluated by using the template matching and Adaboost algorithms. Experimental results on the depression angle showed that the target identification rate of the two algorithms decreased by more than 30% from the depression angle of $45^{\circ}$ to $30^{\circ}$. The accuracy of template matching was about 75.88% while Adaboost showed better results with an accuracy of about 86.80%. In the case of partial occlusion, the accuracy of template matching decreased significantly even in the slight occlusion (from 95.77% under no occlusion to 52.69% under 10% occlusion). The Adaboost algorithm showed better performance with an accuracy of 85.16% in no occlusion condition and 68.48% in 10% occlusion condition. Even in the 50% occlusion condition, the Adaboost provided an accuracy of 52.48%, which was much higher than the template matching (less than 30% under 50% occlusion).

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

Comparison of Subjective Symptoms of Fatigue and Salivary pH among Teachers between Special School and Elementary (피로자각증상(疲勞自覺症狀)과 타액(唾液) pH에 관(關)한 조사연구(調査硏究) - 특수학교(特殊學校) 및 국민학교(國民學校) 교사군간(敎師群間)의 비교(比較) -)

  • Lee, Soon-Ja;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.506-517
    • /
    • 1989
  • Two hundred and fifty teachers of special school (for the disabled) and 414 elementary school teachers were selected for the targets in order to compare their degrees of fatigue symptoms and to find what kind of ralationship is between subjective symptoms of fatigue and pH is the saliva. It was 30 minutes before their closing hours on April 21th, 1989 that their physical, mental and neuro-sensory symptoms and salivary pH were examined. The test results are summarized as fallows : It is observed that an interrelation between subjective fatigue and pH in their saliva shows a significant relationship between physical and neuro-sensory symptoms in a sense of statistics. The rate of subjective fatigue complained by the special teachers is higher than that by the elementary teachers. In the case of salivary pH, the special teachers' is as a whole lower than the elementary teachers'. The complain rates in each item, checked, of special teachers are generally higher than those of the elementary teachers. It is in the mental symptom related item that there are many sub-items which show significant difference. According to the average of salivary pH based on the degrees of complained symptoms shown in the pH related items, the salivary pH of the group with complained symptoms is lower than that of the group without complained symptoms. In the rate of complaints, by sex, both sexes of the special teachers show high ones, but salivary pH is low. The complain rate of mental symptoms shown by female group from the special teacher Is significantly higher(p<0.05). By age, the group in their thirties from the special teachers show the higher complain rate of mental symptoms (29.3%) and the lower salivary pH (p<0.05) than that (15.1%) of the elementary teachers belonging to the same age catagory. However, the special teachers in their forties show the lower complain rate of physical symptoms that of the elementary teachers (p<0.05). From the viewpoint of their working years, the special teachers below 14 years and elementary teachers above 15 years in their career show high complain rates. Among those who belong to the catagory of 10-14 working years, the special teachers show the higher complain rate of mental symptoms than that of their counterparts. In the case of the salivary pH, the special teachers of all working-year catagories show the higher pH than that of the elementary teachers. But there is not significantly difference. From the viewpoint of sleeping hours in the previous night of the questionaire surveyed, among those who slept for over 7 hours, the special teachers show the higher complain rate of mental symptoms with a significant difference, but the lower salivary pH than that of their counterparts. From the viewpoint of their marital status, existence of disease history, the special teachers show the higher complain rate of subjective fatigue, but the lower salivary pH than that of the elementary teachers respectively. According to the above results, the special teachers generally show the higher complain rate of subjective fatigue, the lower salivary pH, and the higher complain rate of mental symptoms. To prevent the possible accumulation of mental fatigue of the special teachers, ways and means to make use of leisure time, recreational facilities are necessarily provided. Since the degree of fatigue and salivary pH have a correlation to some extent, it is necessary that further continuous studies on the correlation between the degrees of fatigue and salivary pH should be pursued.

  • PDF