• 제목/요약/키워드: Test module

검색결과 1,583건 처리시간 0.03초

STEP 기반 LCC 분석 데이터구조를 이용한 LCC 분석모듈 개발 (Development of LCCA Module Using STEP-based LCCA Data Structure)

  • 김동현;;김봉근;이상호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.803-808
    • /
    • 2007
  • LCCA module enabling to estimate LCC and analyze time-variant reliability index of a plate girder bridge was developed. The developed module was based on the designed data structure following the standardized methodology of ISO/STEP, LCCA module consisted of LCC estimation module, which is composed of six sub modules according to the cost category, and reliability index analysis module, which is composed of time-variant corrosion sub module, time-variant live load sub module, and element reliability analysis sub module, The effectiveness of the developed LCCA module was verified by estimating LCC and analyzing time-variant reliability index of a plate girder bridge on the basis of the constructed test database.

  • PDF

멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results -)

  • 김종진;최규성;기호충;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

임베디드 기반의 모바일 LCD 모듈 검사장비 설계 및 구현 (A Design and Implementation of a Mobile Test Device Based-on Embedded System)

  • 김홍규;이기화;문승진
    • 제어로봇시스템학회논문지
    • /
    • 제14권6호
    • /
    • pp.523-529
    • /
    • 2008
  • In this paper, we proposed mobile LCD module test device on embedded based, when operating the existing LCD, divide flicker clearly in full frame, and configuration so as to support between other CPU interface, MDDI, SPI, 24Bit RGB interface, etc. that is based on a high-speed CPU. In addition, when demand to test about each pixel of LCD, it is possible to change IP design of H/W, FPGA, but proposed system is application possible without other design changing. Proposed system is made smaller and equipped with battery, so secure with mobility for effective test the LCD/OLED module and it is able to test the pattern by the client program, for example exiting picture, mpeg, simple pattern test and test per pixel, scale, rotation, Odd/Even pixel per video, etc. From now on, if integrating with independent test system and it is configured that is able to mutual communication and test, it is expected to reduce consumption of human resources and improve productivity for LCD module test.

지상파 DMB 방송웹사이트 서비스 송수신 정합 시험 도구 개발 (Development of Conformance Test Tools for Terrestrial DMB Broadcast Web Site Services)

  • 김용한;문수한;채영석
    • 방송공학회논문지
    • /
    • 제12권3호
    • /
    • pp.214-221
    • /
    • 2007
  • 본 논문에서는 지상파 DMB(Terrestrial Digital Multimedia Broadcasting, T-DMB) 데이터 서비스 중 하나인 방송웹사이트(Broadcast Web Site, BWS) 서비스에 대한 송수신 정합 시험 도구를 개발하였다. 먼저 지상파 DMB BWS 서비스를 위한 송신 측 및 수신 측 정합 시험 방법론을 수립하였다. 시험 도구는 BWS 비트스트림 분석기, BWS 참조 복호 모듈(소프트웨어) 그리고 BWS 시험 비트스트림 등의 세 가지로 구성된다. 송신 측 시험을 위해 BWS 비트스트림 분석기를 개발하였으며, 수신 측 시험을 위해 BWS 참조 복호 모듈을 개발하고 BWS 시험 비트스트림을 제작하였다. 이 시험 비트스트림의 적합성을 검증하는 데 본 논문에서 개발한 비트스트림 분석기가 실제로 사용되었다. 동일한 시험 비트스트림을 시험 대상 BWS 복호 모듈과 참조 복호 모듈에 동시에 입력하고, 이 두 모듈의 결과를 비교함으로써 수신 측 시험을 수행한다. 본 논문에서 개발한 시험 도구들은 MOT 프로토콜, HTML, PNG, MNG, JPEG, Ecma 스트립트 등 BWS에 포함된 모든 프로토콜 및 텍스트/이미지 규격에 대한 시험을 포함한다.

Study of the ageing of hollow fibers in an industrial module for drinking water production

  • Wang, S.;Wyart, Y.;Perot, J.;Nauleau, F.;Moulin, P.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.53-67
    • /
    • 2013
  • In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).

단결정과 다결정 태양전지 모듈의 광학적 특성에 따른 전기적 출력 특성 분석 (Electrical Characteristics Analysis for single-crystalline and multi-crystalline PV module optical character.)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1100-1101
    • /
    • 2008
  • After lamination process, Isc is increased by sheet reflection. This paper presents the electrical output characteristics by back sheet reflection. The experiments was conducted by using single crystalline and multi crystalline PV module. The reflection area of single crystalline PV module is larger than multi one due to the difference of solar cell manufacturing. The experiments show that the increased performance ratio of single crystalline PV module output power is 1.55% rather than that of multi crystalline PV module output power is 1.13%. In addition, it is expected that the output power of single one rather than multi-one is increased by the lower temperature when the PV module is installed outside. The results can be reconsidered by the test material and test process. Back sheet used for humidity prevention makes PV module output power increasing.

  • PDF

A new burn-up module for application in fuel performance calculations targeting the helium production rate in (U,Pu)O2 for fast reactors

  • Cechet, A.;Altieri, S.;Barani, T.;Cognini, L.;Lorenzi, S.;Magni, A.;Pizzocri, D.;Luzzi, L.
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1893-1908
    • /
    • 2021
  • In light of the importance of helium production in influencing the behaviour of fast reactor fuels, in this work we present a burn-up module with the objective to calculate the production of helium in both in-pile and out-of-pile conditions tracking the evolution of 23 alpha-decaying actinides. This burn-up module relies on average microscopic cross-section look-up tables generated via SERPENT high-fidelity calculations and involves the solution of the system of Bateman equations for the selected set of actinide nuclides. The results of the burn-up module are verified in terms of evolution of actinide and helium concentrations by comparing them with the high-fidelity ones from SERPENT, considering two representative test cases of (U,Pu)O2 fuel in fast reactor conditions. In addition, a code-to-code comparison is made with the independent state-of-the-art module TUBRNP (implemented in the TRANSURANUS fuel performance code) for the same test cases. The herein presented burn-up module is available in the SCIANTIX code, designed for coupling with fuel performance codes.

다결정 실리콘 PV모듈의 하절기 표면온도 예측을 위한 알고리즘 검토 및 외부인자별 영향 평가 (Evaluation on Calculation Algorithms for Polycrystalline Silicon PV Module Surface Temperatures by Varying External Factors during the Summer Period)

  • 정동은;염규환;이찬욱;도성록
    • 대한건축학회논문집:구조계
    • /
    • 제35권8호
    • /
    • pp.177-184
    • /
    • 2019
  • Recently, electric power usages and peak loads from buildings are increasing due to higher outdoor air temperatures and/or abnormal climate during the summer period. As one of the eco-friendly measures, a renewable energy system has been received much attention. Particularly, interest on a photovoltaic (PV) system using solar energy has been rapidly increasing in a building sector due to its broad applicability. In using the PV system, one of important factors is the PV efficiency. The normal PV efficiency is determined based on the STC(Standard Test Condition) and the NOCT(Nominal Operating Cell Temperature) performance test. However, the actual PV efficiency is affected by the temperature change at the module surface. Especially, higher module temperatures generally reduce the PV efficiency, and it leads to less power generation from the PV system. Therefore, the analysis of the relation between the module temperature and PV efficiency is required to evaluate the PV performance during the summer period. This study investigates existing algorithms for calculating module surface temperatures and analyzes resultant errors with the algorithms by comparing the measured module temperatures.

IEC 우박시험에 대한 태양광모듈 충돌 해석 (Hail Impact Analysis of Photovoltaic Module using IEC Test)

  • 박정재;박치용;류재웅
    • 한국태양에너지학회 논문집
    • /
    • 제40권4호
    • /
    • pp.23-33
    • /
    • 2020
  • The loss in photovoltaic power due to hailstorms has been highlighted as a major issue in the sustained growth of the PV power plant industry. This study investigates the safety of a solar module by conducting a numerical analysis of a hail test according to the IEC 61215 standard. Our study aims to elucidate the detailed behavior between the ice and solar modules and the micro-cracks forming on solar modules during hailstorms. To analyze the impact of hail, we used the ANSYS AUTODYN software to evaluate the impact characteristics on a solar module with different front glass thicknesses. The simulations show that a solar module with a glass thickness of 4.0 mm results in excellent durability against hail. The results indicate the feasibility of using simulations to analyze and predict micro-cracks on solar modules tailored to various conditions, which can be used to develop new solar modules.

원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발 (Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method)

  • 류재규;손창호;황희정;김건수;최경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF