• Title/Summary/Keyword: Test lamp

Search Result 218, Processing Time 0.031 seconds

Development of an IoT Device for Detecting Escherichia coli from Various Agri-Foods and Production Environments (IoT 적용 대장균 검출기 개발과 농식품 및 생산환경에 적용)

  • Nguyen, Bao Hung;Chu, Hyeonjin;Kim, Won-Il;Hwang, Injun;Kim, Hyun-Ju;Kim, Hwangyong;Ryu, Kyoungyul;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.542-550
    • /
    • 2019
  • To detect Escherichia coli from agri-food and production environments, a device based on IoT (internet of things) technology that can check test results in real time on a mobile phone has been developed. The efficiency of the developed device, which combines an incubator equipped with a UV lamp, a high-resolution camera and software to detect E. coli in the field, was evaluated by measuring the device's temperature, detection limit, and detection time. The device showed a difference between its programmed temperature setting and actual temperature of about 1.0℃. In a detection limit test performed with a single-colony inoculation, a color change to yellow and a florescent signal were detected after 12 and 15 h incubations, respectively. The incubation time also decreased along with increasing bacteria levels. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, detection rates of E. coli using the device were higher than those of the Korean Food Code method. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.

Evaluation of Unexposed Images after Erasure of Image Plate from CR System (CR 시스템에서 IP 잠상의 소거 후 Unexposed Image의 평가)

  • Lim, Bo-Yeon;Park, Hye-Suk;Kim, Ju-Hye;Park, Kwang-Hyun;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.199-207
    • /
    • 2009
  • It is important to initialize Image Plate (IP) completely for removing residual latent image by sodium lamp for reliability and repeatability of computed radiography (CR) system. The purpose of this study was to evaluate latent images of computed radiography (CR) images respect to delay time after erasure of foregone latent image and its effect, and erasure level. Erasure thoroughness for CR acceptance test from American Association of Physicist in Medicine (AAPM) Report 93 (2006) was also evaluated. Measurements were made on a CR (Agfa CR 25; Agfa, BELGIUM) system. Chest postero-anterior (PA), Hand PA, L-spine lateral radiographs were chosen for evaluation. Chest phantom (3D-torso; CIRS, USA) was used for Chest PA and L-spine lateral radiography. For Hand PA radiography, projections was done without phantom. Except Hand PA radiographs, noise was increased with delay time, and ghost image was appeared on overexposed area. Effect of delay after erasure on latent image was not seen on naked eye, but standard deviation (SD) of pixel value on overexposed area was relatively higher than that of other areas. On Hand PA and Chest PA radiographs, noise were not occurred by adjustment of erasure level. On L-spine lateral images at lower erasure level than standard level, noise including ghost image were occurred because of high tube current. Erasure thoroughness of CR system in our department was to be proved by these evaluation. The results of this study could be used as a baseline for IP initialization and reliability of CR images.

  • PDF

Effect of LED Irradiation on Growth Characteristids of Ginseng Cultivated in Plastic Film House

  • Seo, Sang Young;Cho, Jong hyeon;Kim, Chang Su;Kim, Hyo Jin;Kim, Dong Won;An, Min Sil;Yoon, Du Hyeon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.45-45
    • /
    • 2019
  • This experiment was carried out using artificial clay and LED in the plastic film house (irradiation time: 08:00~18:00/day). Seedlings (n = 63 per $3.3m^2$) of ginseng was planted on May 17, 2018. LED was combined with red and blue light in a 3:1 ratio and irradiated with different light intensity. The average air temperature from April to September was $12.3^{\circ}C$ $-26.0^{\circ}C$ and it was the the highest at $26.0^{\circ}C$ in August. The test area where fluorescent lamp was irradiated tended to be somewhat higher than the LED irradiation area. The chemical properties of the test soil are as follows. pH levels was 5.3~5.5, EC levels 0.45~0.52 dS/m and OM levels 33~37%. The total nitrogen content was 0.35~0.47% and the available $P_2O_5$ contents was 13.7~16.0 mg/kg, which was lower than the suitable level of 70~200 mg/kg. Exchangeable cations K and Mg contents were within acceptable ranges, but the Ca contents was $28{\sim}38cmol^+/kg$ levels higher than the permissible level ($2{\sim}6cmol^+/kg$). Germination of ginseng leaves took 8~9 days and the overall germination rate was 70~75%. The photometric characteristics of LED light intensity are as follows. The greater the light intensity, the higher the PAR (Photosynthetic Action Radiation) value, illuminance and solar irradiation. Photosynthetic rate was also increased with higher light intensity was investigated at $1.7{\sim}3.2{\mu}mol\;CO_2/m^2/s$. Leaf temperature ($23.7{\sim}24.8^{\circ}C$) by light intensity was the same trend. The growth of aerial parts (plant height etc.) were generally excellent when irradiated with 3 times the light intensity, the growth of the ginseng aerial parts were excellent as follows. The plant height was 42.6 cm, stem length was 25.2 cm, leaf length was 9.6 cm and stem diameter was 5.0 mm. The growth of underground part (root length etc.) was the same, and the root length was 24.4 cm, the tap root length was 6.0 cm, diameter of taproot was 18.2 mm and the fresh root weight was 17.2 g. There were no disease incidence such as Alternaria blight, Gray mold and Anthracnose. Disease of Damping off occurred 2.2~3.6% and incidence ratio of rusty root ginseng was 14.6~20.7%. Leaf discoloration rate was 13.7~48.9% and increased with increasing light intensity. Ginsenoside content of ginseng by light intensity is under analysis.

  • PDF

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

Properties of Temperature Reduction of Cooling Asphalt Pavements Using High-Reflectivity Paints (고반사 도료를 사용한 차열성 아스팔트 도로포장의 온도저감특성)

  • Hong, Chang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.317-327
    • /
    • 2013
  • Air pollution and artificial heat of urban areas have caused the urban heat island in which asphalt pavements absorb solar heat during the daytime and release the heat at night. Hence, in order to improve the environment of urban areas, it is necessary to examine cooling pavements that can reduce heat on road pavements in urban areas. The application of temperature insulation paints on road pavements require to reduce black brightness for visibility, to increase the reflection rate of infrared light and minimize the reflection rate of visible light. In the study, one part of Acrylic-emulsion was used as a main binder, and the changes in black brightness and the changes of addition ratio (0%, 15%, 30%) of hollow ceramics, as well as kinds of paints (carbon black pigment, mixed mineral pigment) were selected as the main experimental factors. The performance of temperature reduction of cooling pavements was analyzed through the reflection rate of spectrum, the reflection rate of solar heat, and the lamp test. Abrasion resistance, UV accelerated weather resistance, and sliding resistance were tested in real situations. In addition, the performance of heat reduction of testing pavements covered with high-reflection paints was analyzed by using an infrared camera. As the test results, when using mixed mineral paints and hollow ceramic of 30%, the reflection rate of spectrum was 43% in the area of near-infrared ray and 17% in the area of visible light at black brightness of $L^*$=42.89 and the reflection rate of solar heat was 27.5%. Total color difference was ${\Delta}E$=0.27 in the test of UV Accelerated Weather Resistance, indicating almost no changes in color. BPN was more than 53 when scattering #2 and #4 silica sand of more than $0.12kg/m^2$. In Taber's abrasion resistance test, abrasion loss was up to 86.4mg at 500 rotations. The performance of heat reduction was evaluated using an infrared camera at the test section applying high-reflection paints to asphalt pavements, in which the results showed that the temperature was reduced by $12.7^{\circ}C$ on CI-30-40 cooling pavements ($L^*$=38.76) and by $14.2^{\circ}C$ on CI-30-60 cooling pavements ($L^*$=57.12).

Effect of treadmill exercise on autophagy related protein expression in the cardiac muscle of high-fat diet fed rats (트레드밀 운동이 고지방 식이 쥐 심근세포의 자가포식 관련 단백질 발현에 미치는 영향)

  • Jeong, Jae-Hoon;Kang, Eun-Bum
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.91-101
    • /
    • 2020
  • The purpose of this study was to investigate the influence of obesity on the expression of autophagy-related proteins in cardiac muscle. To this end, obesity was induced in rats through 20 weeks of high-fat diet, and the animals were then subjected to 8 weeks of treadmill exercise. Subsequently, the expression of proteins that regulate the induction of autophagy, formation of autophagosome, and fusion of autophagosome and lysosome was confirmed. Obesity was induced in the experimental animals (SD rats) through 20 weeks of high-fat diet (carbohydrate: 20%, fat: 60%, and protein: 20%), and they were subsequently subjected to 8 weeks of treadmill exercise (5 days/week, 30 min/day, 5 minutes; 8m/min, 5 minutes; 11m/min, 20 minutes; 14m/min). The experimental groups comprised the normal diet control group (ND-CON, n=10), high-fat diet comparison group (HFD-CON, n=10), and high-fat exercise group (HFD-TE, n=10). Oral glucose tolerance test was conducted before and after 8 weeks of treadmill exercise, and the area under the curve (AUC) was calculated. Through fasting insulin and fasting glucose levels, HOMA-IR, which is an index of insulin resistance, and abdominal visceral fat/body weight (AVF/BW) were calculated for comparison. Moreover, autophagy-related proteins were analyzed from cardiac tissue to investigate the effects of exercise training. Obesity was successfully induced in the HFD-CON group through long-term high-fat diet, and the HFD-CON group had higher body weight, AUC, HOMA-IR, and AVF/BW compared to the ND-CON group. The HFD-TE group, which underwent 8 weeks of treadmill exercise, showed improvements in AUC, HOMA-IR, and AVF/BW. Although the body weight tended to decrease as well, there was no statistically significant difference. mTOR and AMPK, which are involved in the induction of autophagy, both decreased in obesity but increased upon exercise. Beclin-1, BNIP3, ATG-7, p62, and LC3, which are related to the formation of autophagosomes, all increased in obesity and decreased after exercise. Cathepsin L and LAMP2, which regulate the fusion of autophagosome and lysosome, both decreased in obesity and increased upon exercise. Physical activity, including treadmill exercise, was found to induce normal autophagy and improve pathological phenomena observed in metabolic diseases. Therefore, the findings suggest the need to consider treadmill exercise as a primary means to achieve effective prevention and treatment of cardiac diseases.

Marsupialization of the Nictitating Membrane Cyst Following Cherry Eye Repair in a Dog

  • Kim, Sunhyo;Kang, Seon-mi;Susanti, Lina;Kim, Boyun;Park, Yoonji;Shim, Jaeho;Go, Seokmin;Lee, Eunji;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.149-152
    • /
    • 2020
  • One-year-old male Cocker Spaniel dog was referred for the third eyelid enlargement and inflammation in the left eye (OS). It gradually swelled for 2 weeks after the cherry eye repair by conjunctival mucosa pocket procedure at a private animal clinic. Routine ophthalmic examinations including neuro-ophthalmic examination, Schirmer tear test, intraocular pressure and corneal fluorescein staining were all normal. No lesions were found on slit lamp biomicroscopy and indirect ophthalmoscopy except for third eyelid swelling in the OS. Ultrasonography revealed cystic structure within the OS nictitating membrane. Fluid from the cyst was aspirated and there were no microorganisms or neoplastic changes. Surgical intervention was performed under general anesthesia. On the day of the surgery, there was a deep corneal ulcer in the OS, which had not existed before. Ventral palpebral surface of the third eyelid was incised horizontally to the shaft of the T-shaped hyaline cartilage. And then, a full thickness of the cystic wall was incised and marsupialized. Additionally, a direct suture was performed on the ulcerated cornea. Topical and systemic antibiotics and anti-inflammatory drugs were prescribed. One month after the surgery, the third eyelid swelling and the discharge were improved. Marsupialization of the nictitating membrane cyst relieved the swelling of the third eyelid and inflammation. It could be a simple but effective surgical intervention for the cystic complication of conjunctival mucosa pocket procedure in dogs.

Grade Classification of Urushi Lacquer (I) Grade Classification of Urushi Lacquer by Traditional Method (옻칠의 품등 구분 (I) 전통적인 방법에 의한 옻칠의 품등구분)

  • Roh, Jeong-Kwan;Kim, Yun-Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.105-112
    • /
    • 2008
  • Grading of the urushi lacquer is quite difficult because of large variations depending on origin, growing conditions, time acquisition, storage conditions. It is urgently required to establish a grading system of urushi lacquer by combining traditional method with scientific methods. Traditional grading of urushi lacquer was done by visual inspection of 10 experts who are working on urushi lacquer industry. Common aspects of the experts were color, odor, viscosity, spread properties on Hanji, color and drying properties on glass based the traditional grading system. In addition, rubbing on Hannj and heating with alcohol lamp was also used to grade urushi lacquer. The grading results of 10 experts showed that chinese urushi lacquer (E) of 7.03, japanese urushi lacquer (C) of 6.84, domestic urushi lacquer of (A) of 6.41 and another chinese urushi lacquer (D) of 5.27, and domestic urushi lacquer (B) of 2.50 in descending order. The degree of spread on Hanji was not consistent among 10 experts. These results indicated that the traditional grading system was pretty much personal and required of developing more objective method based on scientific background.

Design of Illumination Control System Using Microwave Sensors and Dimming Control (마이크로웨이브센서와 디밍제어를 활용한 조명제어시스템 설계 및 구현)

  • Song, Eun-Seong;Min, Byoung-Won;Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.19-26
    • /
    • 2013
  • In this paper, we present a novel illumination system for parking lots constructed underground. We design and implement this system using microwave sensors and dimming control of LED fluorescent lamps so that we can obtain lighting efficiency of the illumination scheme. We construct an effective illumination system in the aspects of performance and cost, resulting in energy-saving and electricity reduction. Recently conventional energy-saving method applied to old underground parking lots mainly relies upon turning off the half of total number of lamps installed in the parking lot. Sometimes there are some lots that have infrared sensor to be used to turn on/off the fluorescent lamps to realize these operations smoothing. The other schemes utilize timer to control lighting time of the fluorescent lamps. These conventional schemes are forcing to turn off a part of lamps installed so that we cannot apply them in a systematic way. Moreover they will be most inefficient when we leave them alone to be continuous consumers. The lighting control system proposed in this paper can recognize objects through microwave sensors and inform the appropriate lighting time, furthermore we can adjust brightness of LED lamps following the surroundings using dimming control scheme so that we can epochally improve the illumination system for underground parking lots. According to our sophisticated test experiments, we can maximally obtain 81.9% of energy-saving effectiveness using the system proposed in this paper.

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.